Industrial Filtration Systems Dealers in Andheri East, Mumbai

(12 products available)
  • Single and Multiple Filter Housing Systems

    Single and Multiple Filter Housing Systems

    Get Price Quote

    It was developed by BLINEX FILTER-COAT PVT LTD in 1978 for the first time in India remarkable Single And Multiple Candle Plastic Filter Housing . The cartridge is of Polypropylene and available form 0.5 to 250 microns. The range of Industrial Non-metallic Housing/System offers an economical answer to low flow requirements. Non-metallic housings are available in a number of materials of construction to suit a range of chemical applications. These strong industrial designed housings are ideally suited for use for flows of potable water. The unit is polycarbonate bowl with ABS cap. Properties: Filter the finest suspended particles. The cartridges have uniform pore size, smooth surface, lightweight, odorless, tasteless, non-toxic, resistant to shocks and impacts. The unit withstands the pressure upto 150 PSI. The flow rate form 4 to 15 LPM in different microns cartridge. Typical Application: Air regulators filters Aquarium Aerators Breather vents Marker tip Controlled metering devices Foaming devices Water conditioning filters Pneumatic mufflers Filtration support media Battery flame arrestors ETO vents Chromatography frits Production of defined foams Introduction of oxygen into water Drying Cooling Stripping of solvents Silencing the insulation Diaphragms for electrochemical processes. Application On Various End Uses: Filtration of domestic and industrial water, air, gas, oil, syrups, electroplating and photography solution

    more..
  • indoor unit filter system

    indoor unit filter system

    Get Price Quote

      The Indoor Unit is ideal for small offices, houses, retail outlets, hospitals and clinics. The unit makes up to 20 liters per day in relative humidity of 50%. The unit is also equipped to use city water as the input source to deal with a sudden increase in demand. The superior filter system in this unit ensures that the dispensed water is filtered through a three stage filter i.e. carbon , sediment and ultra filter, thus removing all unwanted particles, odor and delivering pure water with less than 0.02 micron partial. With recent advanced technologies like ozonation, the water is treated with ozone to kill all the harmful bacteria and viruses to produce pure & safe drinking water. Features:  Water Filtration system:Carbon, Sediment, Ultra Filter, Ozonation    Size: W 450 x L 450 x H 1250 mm.  Dispensing: Mechanical dispensing system  Water Flow from the collection tank: Sediment filter, Carbon filter 1, Reverse Osmosis, Carbon filter 2, then the 1st UV Light.  Noise: Less than 60 decibels  Facia: Plastic or metal options  Water Storage: 20 liters (10 liters – Purified water + 10 liters -Collected water)  Cooling: Cold water up to 6°C

    more..
  • Best Deals from Industrial Filtration Systems

  • MULTIPLE FILTER HOUSING SYSTEMS

    MULTIPLE FILTER HOUSING SYSTEMS

    Get Price Quote

    • Pressure: upto 150 PSI

    The cartridge is of Polypropylene and available form 0.5 to 250 microns. The range of Industrial Non-metallic HousingSystem offers an economical answer to low flow requirements. Non-metallic housings are available in a number of materials of construction to suit a range of chemical applications.

    more..
  • CATALYST FILTER SYSTEM

    CATALYST FILTER SYSTEM

    Get Price Quote

    CATALYST FILTERS FOR HYDROGENATORS AND AUTOCLAVES Catalyst filtration is an important aspect of a Hydrogenation system. Omega- Kemix supplies a cost effective system, which incorporates. Complete filtration Operational safety Full backwash Minimal holdup of the reaction mass The filter is Fitted with sintered candles Has a special Heel filter Provided with a sight flow indicator Provided with special valves for effective dislodgement of catalyst cake Omega-Kemix make filter has the following advantages Safe procedure for catalyst filtration from the Autoclave There is no spillage of expensive catalyst Closed circuit operation avoids fire hazards in case of pyophoric catalysts High efficiency candles result in very low losses, which are often below measurable limits The filtration system pays for itself through high rate of catalyst recovery CATALYST FILTERS FOR HYDROGENATORS AND AUTOCLAVES: Catalyst filtration is an important aspect of a Hydrogenation system. Omega ‐ Kemix supplies a cost effective system, which incorporates complete filtration, operational safety, full backwash, as well as minimal holdup of the reaction mass. OPERATING PRINCIPLE AND PROCEDURE: At the completion of hydrogenation reaction, balance Hydrogen gas in reactor headspace is vented, and the Reactor is purged with Nitrogen, to eliminate all traces of remaining Hydrogen. Subsequently, the Reactor is pressurized to about 1 bar with Nitrogen, through Valve V1 Valves V2, V3 and V4 are opened. All othe valves (V5 to V8) are in closed position. Nitrogen is continuously fed through Valve V1, so that Reactor pressure is maintained around 1 bar. Typically, if the catalyst is noble metal on a carrier, e.g., Pd/C, the entire mass is filtered. In this case, it is advisable to stir the reaction mass at around 50 RPM, and the dip pipe or blow leg should extend to the lowest possible point in the Reactor. For heavy metal catalysts like Raney Nickel, the bulk of the catalyst settles within a very short time, typically 30 minutes after cessation of stirring. In this case, a common practice is to filter the supernatant liquid (through a dip pipe terminating just below the lower tan line of the Reactor). Nitrogen pressure in the Reactor headspace forces the liquid‐catalyst slurry into the Main Filter through Valve V₃. This filter is fitted with sintered SS 316 L candles, suspended from a tubesheet. These candles also have a 0.2 micron thick vapor deposited Stainless Steel membrane, of the desired micron size, typically 1 to 3 μ. Initially, the Filter body fills up with Liquid‐catalyst slurry. When it is full, filtration commences. Catalyst cake accumulates outside the candles. Clear filtrate enters the candles, and flows out through Valve V4. Filtrate flow can be observed through Sight Flow Indicator (FI). Once the Reactor contents are entirely displaced by Nitrogen, gas will flow into the Filter through V3. The Filter Candles are fitted with an inner Siphon Tube. Gas entering the Filter displaces the slurry, so that clear liquid is siphoned out through Valve V4, due to action of siphon tubes in the candles. Due to this action, slurr level in the Filter falls to the lower end of the candles. In effect, the filter cone and lower parts are full of unfiltered slurry (also known as "Heel"), and candles are coated with wet cake. At this point, only gas flows through the Sight Flow Indicator. A Zero Holdup Filter is fitted at the lower end of the Main Filter, below the conical portion. This is a Jacketed Sintered pipe (or Lower Candle), around 125 mm inside diameter, suitable for inside to outside filtration. The sintered pipe has a similar 0.2 micron thick vapor deposited Stainless Steel membrane on the inside, to facilitate surface filtration. Please refer Drawing 2 for details of the Zero Holdup Filter. When gas flow (i.e., no liquid flow) is observed through the Sight Flow indicator as described above, Valve V4is closed, and V₉ is opened. Nitrogen gas entering the Filter cone forces filtrate through the Lower Candle, so that slurry in the Filter Cone and lower parts is filtered through the Zero Holdup Filter. Heel filtrate is observed flowing through the Sight Flow Indicator FI. Once the entire heel slurry is filtered, no further liquid flow is observed through the Sight Flow Indicator. All the slurry has been filtered. At this stage, outer surfaces of the upper candles, and inner surface of the lower candle are covered with wet cake. Valves V9, V3 and V2 and V1 are now closed, and the Reacto vented to atmospheric pressure, by opening Valve V10. Solvent/feed for the next batch, or Nitrogen at 1 to 5 bar is introduced at Valve V5, located at the top of the Filter. Keeping Valve V10 open, Valve V8 and then Valve V6 is opened, so that catalyst adhering to candle surfaces gets back‐flushed into the Reactor. For best results, Valve V6 should be a Solenoid operated ball valve, so that there is a pressure pulse while opening this valve. This ensures effective dislodgement of catalyst cake from the Candles. This procedure ensures a safe procedure for catalyst filtration from the Autoclave. There is no spillage of expensive catalyst. The closed circuit operation avoids fire hazards, as many catalysts are pyrophoric, and can spontaneously ignite when exposed to air. High efficiency candles result in very low losses, which are often below measurable limits. The filtration system pays for itself. After several batch cycles, it may be necessary to remove catalyst from the system, and send it for disposal or regeneration. In this case, Valve V7 is opened instead of V8, during back flushing operation, and spent catalyst collected in the Recycle Drum.

    more..
  • industrial filtration systems

    industrial filtration systems

    Get Price Quote

    industrial filtration systems, chemical nozzles

    more..
  • Liquid Filtration Unit

    Liquid Filtration Unit

    Get Price Quote

    OPERATION : The liquid to be filtered is forced in the chamber by the Transfer pump, where it finds its way to the top of the filter media of each plate through circular opening on the side of the plates. Under pressure clear Liquid passes through the filter media leaving suspended particles on top of the filter. The clear filtrate runs down through central channel formed by the interlocking cups and exists through the outlet valve. FEATURES : Single pass clear filtration.Full batch recovery of the filtrate. Easy install inside cartridge  assembly.Complete cake retains on the plate. Uniform distribution of cake on each plate. Reduce the cost of treatment of catalyst, Toxic Chemicals. Less exposure to the operating person. No contamination of the internal surface of the shell. ADVANTAGES : Zero retention in filter vessel.   APPLICATION : To filter final product in Pharmaceuticals, Perfumes, I. V. Fluids, Dyes & Chemicals, Activated carbon, Pesticides, Cosmetics, Varnishes, Polymers, Resins & Paints, Sugar syrup, Food, Plant Water Polishing, Fruit juice, Soft drink, Beer & Liquors, Edible & Non Edible oils. SIZE AVAILABLE :               8” / 14” / 15” / 24” & 33” dia. TECHNICAL SPECIFICATION :

    more..
  • Swimming Pools Filters Systems

    Get Price Quote

    We are engaged in supplying a quality range of pool filtration systems. Offered range of filtration systems offered by us consists of swimming pool filtration system. These systems are manufactured at our vendors sophisticated infrastructure, under the supervision of experienced professionals.

    more..
  • thermic fluid filtration system

    Get Price Quote

    thermic fluid filtration system, spiral ro membranes

    more..
  • Mobile Filtration Systems

    Get Price Quote

    Mobile Filtration Systems, Load Sensing Valves, Oil Condition Sensors

    more..
  • filter housing systems

    Get Price Quote

    filter housing systems, Aerator, stainless steel filter disc, teflon lining

    more..
  • filter system

    Get Price Quote

    filter system, Filter Papers, Filter Pads

    more..
  • industrial uv system

    Get Price Quote

    Chlorine Dioxide Generator, Uv System

    more..
Filter by Locality
top