WATER LEAK SENSOR CABLE
Addressable Water Leak Sensor Cable - Addressable Water Leak Sensor Cable Manufacturer of a wide range of products which include Sontay Sensor Cable With J3 Four Zone Wld Panel, Sontay Water Leak Sensor Cable, RLE Addressable Water Leak Sensor Cable and Conventional Water Leak Sensor Cable.J3-Saini Ad-09: sensing cable detects conductive liquids anywhere along its length. After installed with a J3 water leak detection panel alarm or other module, once the cable senses the leakage of liquids, it will trigger an alarm. The sensor cable can detect the leakage of water, weak-acid extra. STABLE STRUCTURE: J3-Saini Ad-09: sensor cable was consisted of two sensing cable. Internal of two sensing cable is metal wire and outside of cable is conducting polymer to make J3 sensing cable mechanically strong and chemically resistant. This rugged construction allows the cable to perform well, even in demanding environments. ADVANCED TECHNOLOGY: Sensor cable processed into helical structure contrast to parallel structure, it can greatly reduce electromagnetic interference and misstatement rate. The characteristic of sensor cable is as follow, small and portable, strong flexibility, easy setup, and unique design. These make the cable dry quickly and stop alarm to let module reset rapidly. J3-Saini Ad-09 sensor cable is made by anti-corrosion, low smoke and innoxious material. FLEXIBLE DESIGN: The sensor cable can be provided custom length of multiple of 5 meter so that it can suitable to use in different areas and monitor subfloors, and double-containment piping, data centre, manufacturing process, telecommunication, electric room etc.
...moreWater Leak Detection Panel
Rat Repellent For Home
We believe in transparency when it comes to payment of advance or full cost. We provide our patrons with numerous payment options for their convenience and ensure the methods are safe. Our packaging materials can retain the products' quality and newness even under extreme shipping and handling conditions. Our packaging provides optimum physical protection. Scientific and Effective 3 bands ultrasonic waves Frequency changes intermittently Safe, No Risk of Fire Fireproof materials External Fuse Cover in Extensive Range : 150 Square Meters per unit Dominant Trend of Pest Control Market Poisons and pesticides are less eco-friendly, and people may eat them by mistake. Multiple glue traps and cages are needed to buy repeatedly. Ultrasonic pest repellers are safe, energy- saving and easy to use. High Quality Guarantees Coverage : It can reach to 250m2 (2690 Sqft.) We suggest 150m2 (1620 Sqft.) per unit when using. Frequency changes intermittently : The rodents are unable to adapt.Ultrasound level : 110 dB. Ultrasonic speaker : Top product in the field. Microchip : From World Famous Product Safety Guarantees Special ultrasonic waves: act upon the rodents but not humans. Fireproof Materials : The Product won't catch fire. External fuse : Internal circuit won't be damaged. Full voltage setting : can be used universally. 16-core wire : More, more reassuring. Free From poisons, pesticides and traps: no potential physical J3 ULTRASONIC RATE REPELLER ADVANTAGES : Why to waster or pay more our hard earning money for Ultrasonic pest Repeller Panels & Transducer which are Available in the Market and also have less effect on Rats and more Expensive. To install panel and Transducer technician or Electrician is required but J3 Technology Ultrasonic Rat Repeller is very simply to install Plug and Pay no Engineer is required for the same only you have to plug in the 230Volt Socket that all. Speciallty in J3 Technology Ultrasonic Rat Repeller No need to change the Frequency manually likes other Companys panels it automatically changes the same due to which Rat get Irritate and leave the Premises Immediately.
...moreRat Repellent For Automobile
The basic materials that we use for the manufacturing of our entire range are thoroughly checked against numerous quality parameters. Thus, we make sure that we deliver faultless products to the clients. We have developed state-of-the-art storage facility wherein we keep a large stock. It also prevents our offerings from air, duct, sunlight and other damaging factors. AUTO RAT REPELLER IS JUST FOR AUTOMOBILE Applying Space <50M2 Design : Regular Customized : Non - Customized Pest Control Types : Rat, Expel, Chase Item Name : Auto Rate Repeller Type : Ultrasonic Power Supply : Electric Pest Types : Mouse, Rat, Rodent Product Name : Auto Mouse Repeller Other Name : Vechicle Mouse Repeller Strong Ultrasound Bright LED light Model.No.J3-999 Main Specifications Power Voltage:12V DC Average Power: 40mA Ultrasonic Frequency: 20Khz---70Khz Ultrasonic Level:118dB(Not Audible to Humans) Coverage:100m2 under open environment Product Size:85X85X25mm Net Weight: 120g WARRANTY: 1 year PACKING: 1Nos. (incl. of Taxes) J3 ULTRASONIC RATE REPELLER ADVANTAGES : Why to waster or pay more our hard earning money for Ultrasonic pest Repeller Panels & Transducer which are Available in the Market and also have less effect on Rats and more Expensive. To install panel and Transducer technician or Electrician is required but J3 Technology Ultrasonic Rat Repeller is very simply to install Plug and Pay no Engineer is required for the same only you have to plug in the 230Volt Socket that all. Speciallty in J3 Technology Ultrasonic Rat Repeller No need to change the Frequency manually likes other Companys panels it automatically changes the same due to which Rat get Irritate and leave the Premises Immediately.
...moreFire Hydrant System
Fire Hydrant
Fire Hydrant and Sprinkler System are considered to be the most effective and economical way to apply water from fixed systems. It is designed to act upon a fire at a pre-determined temperature by means of a water spray. It could extinguish the fire or control its spread. The extinguishing mechanism of sprinkler water spray includes combustible materials to prevent further fire spread and displacement of combustible vapour and oxygen steam. The sensitivity of the sprinkler heat is dependent on the nominal rating of its glass bulb, which varies from 570° oC - 260° oC and is identified by different colour codes. When considering the increase of the compartment size, or the reduction in passive fire protection systems by using sprinkler systems, the sprinkler system should meet the relevant recommendations by commonly used standards such as BS 5306 : part 2, i.e., The relevant occupancy rating together with the additional requirements for life safety. The sensitivity of the sprinkler heat is dependent on the nominal rating of its glass bulb, which varies from 570° oC - 260° oC and is identified by different colour codes. When considering the increase of the compartment size, or the reduction in passive fire protection systems by using sprinkler systems, the sprinkler system should meet the relevant recommendations by commonly used standards such as BS 5306 : part 2, i.e., The relevant occupancy rating together with the additional requirements for life safety. There are four main types of sprinkler systems - wet, dry, alternate and pre-action system. They are normally chosen by the nature of the area to be protected, whether storage of water in the pipework would pose a risk due to process or weather condition, or where the risk of accidental discharge is to be eliminated. Fire Hydrants Or hydrant outlets, are installed within the building to enable firefighters to connect their hoses to a water supply to fight. Fire hydrants may be of the dry type which are empty in normal situations, but are charged with water supplied through fire brigade's pumping appliance to the inlet at ground level in the building perimeter during emergency. Alternatively, they may be kept full of water and supplied from tanks and pumps in the building. Normally, the wet fire hydrants are also coupled with fire service inlets. These are located at the perimeter of the building to enable water from the external source to be fed into the building via the fire brigade's pumping alliance. Building height generally determines which type is used. It is also important in the planning stage to ensure that an external source of water supply. Such as street hydrants, is within reasonable distance from the building. The fire service should not have to travel far form an external water source.
...moreElectric Flying Insect Killer For Office
For maximum customer satisfaction, we ensure that the product reaches the customer in the said time slot, owing to our reliable shipping facilities. Only quality packing material has been used for the packing of the products. Customers can stay rest assured for the safe delivery of the orders as our experts keep a vigil eye on the entire procedure. ELECTRIC FLYING INSECT KILLER FOR OFFICE Pest Type : Flying Insects Mosquito, Moth, Housefly, Bug Pest Control Type : Kill / Trap Feature : Disposable, Eco-Friendly, Stocked Place of Origin : Zhejiang, China (Mainland) Brand Name : J3 Electric flying Insect Killer Model Number : HCM-1601 Product Name : Fly Bug Insect Trap Color : White Material : ABS Plastic Function : Kill Flying Insects Mosquito, Moth, Housefly, Bug Certificate : CE, RoHS, CCC, Quality Testing Report Type : Trap Product Size : 380mm*160mm*220mm Usage : Indoor Packing : White Box Power Supply : 100-260V AC, 50/60Hz ELECTRIC FLYING INSECT KILLER FOR HOME Replace the sticky trap generally, the sticky trap has to be replace every three days. But if fan is used frequently, the time for such replacement can be extended, for example, every six days. If there are fewer mosquitoes and flies stuck on the trap it is no need to change until there are more on it. Clean the storage box: when the product is used for the first time, there will be a lot of flying insects leaving in the box, so you have to clean the storage box daily. Directly pull out the box and pour the bodies out. Clean the fan: if there is much dust attached to the fan, you need to clean the fan with brush or toothbrush. Clean the tube: if there is much dust attached to the tube, you need to clean it gently with a dry cloth
...moreElectric Flying Insect Killer For Home
Our well-structured warehouse is properly maintained and equipped with modern amenities, thus assist us wholly in meeting bulk requirements of the customers. We assure you to deliver goods to the desired place, as we have strong distribution network and shipping facilities. ELECTRIC FLYING INSECT KILLER FOR HOME Pest Type : Flying Insects Mosquito, Moth, Housefly, Bug Pest Control Type : Kill / Trap Feature : Disposable, Eco-Friendly, Stocked Place of Origin : Zhejiang, China (Mainland) Brand Name : J3 Electric flying Insect Killer Model Number : HCM-1601 Product Name : Fly Bug Insect Trap Color : White Material : ABS Plastic Function : Kill Flying Insects Mosquito, Moth, Housefly, Bug Certificate : CE, RoHS, CCC, Quality Testing Report Type : Trap Product Size : 380mm*160mm*220mm Usage : Indoor Packing : White Box Power Supply : 100-260V AC, 50/60Hz J3 ELECTRIC FLYING INSECT KILLER FOR HOME Replace the sticky trap generally, the sticky trap has to be replace every three days. But if fan is used frequently, the time for such replacement can be extended, for example, every six days. If there are fewer mosquitoes and flies stuck on the trap it is no need to change until there are more on it. Clean the storage box: when the product is used for the first time, there will be a lot of flying insects leaving in the box, so you have to clean the storage box daily. Directly pull out the box and pour the bodies out. Clean the fan: if there is much dust attached to the fan, you need to clean the fan with brush or toothbrush. Clean the tube: if there is much dust attached to the tube, you need to clean it gently with a dry cloth
...moreConventional Sensor Cable
Placed in Maharashtra(India), we are an entity acknowledged for our superior products and matchless services. We have developed several offline as well as online options for the convenience of clients to ensure faster trade. SPECIFICATION: J3-Saini C-99 Material PVC Twisted pair with stainless steel sensing elements Dimensions 4.5mm dia. (0.17") Leader cable length 2m (6.5ft) . PART CODES: J3-Saini C-99 Water Cable Sensor Sensing Cable Length (add type to above code) -2Mtr - 2 meters (6.56ft) -5Mtr - 5 meters (16.4ft) -10Mtr - 10 meters (32.81ft) -15Mtr - 15 meters (49.21ft) -20Mtr - 20meters (65.62ft) -25M - 25 meters (82.02ft) Custom lengths available on request. INSTALLATION (J3-Saini C-99): Fit the cable sensor to the floor, using the J3 Clips or other suitable nonconductive fixings. Connect the 2 core leader cable to the J3 Saint Panel or alarm module and terminate at the sensor input (polarity independent). The cable can be extended if required using a 2-core cable to a maximum of 100 meters (328ft). You can test the cable by placing a wet cloth over the cable to simulate a water leak, the J3 Water Leak Panel will come on in Alarm. Remove the rag and when the cable driest Normal the panel kindly press the Reset key on the Panel.
...moreAutomatic Sprinkler
Addressable Water Leak Sensor Cable
We have well-connected and capacious warehouse that helps us in arranging products systematically to deal with urgent deliveries and orders. Our exceptionally good warehouse system helps us in keeping the products safe till the final dispatch. One-stop destination for presenting quality Addressable Water Leak Sensor Cable, we are a notable supplier in this field. STABLE STRUCTURE: J3-Saini Ad-09: sensor cable was consisted of two sensing cable. Internal of two sensing cable is metal wire and outside of cable is conducting polymer to make J3 sensing cable mechanically strong and chemically resistant. This rugged construction allows the cable to perform well, even in demanding environments. ADVANCED TECHNOLOGY: Sensor cable processed into helical structure contrast to parallel structure, it can greatly reduce electromagnetic interference and misstatement rate. The characteristic of sensor cable is as follow, small and portable, strong flexibility, easy setup, and unique design. These make the cable dry quickly and stop alarm to let module reset rapidly. J3-Saini Ad-09 sensor cable is made by anti-corrosion, low smoke and innoxious material. FLEXIBLE DESIGN: The sensor cable can be provided custom length of multiple of 5 meter so that it can suitable to use in different areas and monitor subfloors, and double-containment piping, data centre, manufacturing process, telecommunication, electric room etc.
...moreSPRINKLER SYSTEM
fire hydrant and sprinkler system are considered to be the most effective and economical way to apply water from fixed systems. It is designed to act upon a fire at a pre-determined temperature by means of a water spray. It could extinguish the fire or control its spread. The extinguishing mechanism of sprinkler water spray includes combustible materials to prevent further fire spread and displacement of combustible vapour and oxygen steam. The sensitivity of the sprinkler heat is dependent on the nominal rating of its glass bulb, which varies from 570 oc – 2600 oc and is identified by different colour codes. When considering the increase of the compartment size, or the reduction in passive fire protection systems by using sprinkler systems, the sprinkler system should meet the relevant recommendations by commonly used standards such as bs 5306 : part 2, i.e., the relevant occupancy rating together with the additional requirements for life safety. the design of a sprinkler system is determined by the hazard classification of the building occupancy. Each category has its own minimum design density of discharge and assumed maximum area over which this design density is to be achieved. there are four main types of sprinkler systems – wet, dry, alternate and pre-action system. They are normally chosen by the nature of the area to be protected, whether storage of water in the pipework would pose a risk due to process or weather condition, or where the risk of accidental discharge is to be eliminated. fire hydrants or hydrant outlets, are installed within the building to enable firefighters to connect their hoses to a water supply to fight fires. Fire hydrants may be of the dry type which are empty in normal situations, but are charged with water supplied through fire brigade's pumping appliance to the inlet at ground level in the building perimeter during emergency. Alternatively, they may be kept full of water and supplied from tanks and pumps in the building. Normally, the wet fire hydrants are also coupled with fire service inlets. These are located at the perimeter of the building to enable water from the external source to be fed into the building via the fire brigade's pumping alliance. Building height generally determines which type is used. it is also important in the planning stage to ensure that an external source of water supply. Such as street hydrants, is within reasonable distance from the building. The fire service should not have to travel far form an external water source. first – aid appliancethis is the use of first aid fire fighting equipment such as hose reels accompanying the manual alarm call point, the portable fire extinguishers etc. They are meant to be the first line of defense by the occupants themselves who spot the fire before the arrival of fire brigades and are designed too. sprinkler systemsautomatic sprinkler systems are considered to be the most effective and economical way to apply water from fixed systems. It is designed to act upon a fire at a pre-determined temperature by means of a water spray. It could extinguish the fire or control its spread’s the extinguishing mechanism of sprinkler water spray includes combustible matenals to prevent further fire spread and displacement of combustible vapour and oxygen steam. The sensitivity of the sprinkler heat is dependent on the nominal rating of its glass bulb, which varies from 570oc – 2600oc and is identified by different colour codes. When considering the increase of the compartment size. Or the reduction in passive fire protection systems by using sprinkler systems. The sprinkler system should meet the relevant recommendations of commonly used standards such as bs 5306 : part 2, i.e. The relevant occupancy rating together with the additional requirements for the safety. the design of a sprinkler system is determined by the hazard classification of the building occupancy. Each category has its own minimum design density of discharge and assumed maximum area over which this design density is to be achieved. there are four main types of sprinkler systems – wel. Dry. Alternate and pre-action system. They are normally chosen by the nature of the area to be protected. Whether storage of water in the pipework would pose a risk due to process or weather condition, or where the risk of accidental discharge is to be eliminated.
...moreParking Space Management
Parking is a big problem these days for malls, hospitals, hotels, cinema halls and multiplexes. For managing such a difficult task, we bring forth reliable Parking Management Services. The officers engaged in providing Parking Management Services are well-trained, intelligent and hard-working.
...moreBe first to Rate
Rate ThisOpening Hours