Three Phase transformer
800,000 Per Set
01 Set(s) (MOQ)
transformer of various capacity & various type avaialable .
Brand Name : Power Star
Certification : ISI Certified
Usage : Industrial Use
Usage : Distribution
Phase : 3 Phase
...moreSound Proof Acoustic Enclosures
01 Piece (MOQ)
We at jaideep power solution pvt ltd, manufacture an acoustic enclosure with our innovative techniques and keeping in view the following: a. adequate ventilation for genset cooling air requirement. B. absorbent insulating rockwool of 96 density material is used which is fire radiant. C. suitable thermal lagging to avoid localized heating of adjoining part of exhaust. D. easy access to service points on gensets. E. temp. Of enclosure does not exceed beyond 7 deg. Of ambient temp. f. 75dba at 1 mtr. Distance as per cpcb norms. G. 7 tanks anti rust treatments process is being used on panel. H. high class powder quoting is being done on all the panels for better finish and long life of panels. Canopy specification: 1) construction details specifications outer body – 1.6mm thk, (16g) com, doors – 1.6mm thk, (16g) crca sheet. 2) wall thichness – 100 mm thk. 3) base frame in 75 x 35 x 5 mm ‘in ‘c’ channel. 4) the acoustic is composite in construction & is a fully assembled integralunit. 5) rockwool 96 density will be used. 6) perforated sheet 22 guage. 7) the genset is easily maintanable. 8) the acoustic enclosure parts will be coated after pre. Treatment process the powder coatingshed will be ‘onan green’.
...moreRing Main Unit
500,000 Per Set
01 Set(s) (MOQ)
ring main unit cromton/abb make .
Brand Name : CROMTON & ABB
Voltage : 415
POWER STAR TRANSFORMER
800,000 Per Set
01 Set(s) (MOQ)
transformer of various capacity & various type avaialable.
Brand Name : Power Star
Application : Distribution
Output Type : Yes
Phase : 3 Phase
Coil Number : 5
Connection : All Type
...more5KVA Mahindra Portable Generator
172,000 Per Set
01 Set (MOQ)
we thank you very much for your trust shown to us for all these years and here with attach a photograph for 5 kva mahindra portable d g set which runs on castors and consumption for 1 hours shall be 1,05litres/hours. the advantages is as follows:- 01) runs on diesel, which is readily available. 02) compact in size and moves on castors. 03) button start. 04) very rugged. new model spectro the size and weight:- attached photo & specification of new model length :-1050mm breadth :- 700mm height :-825mm weigth :- 225kg . prices all inclusive.
Type : Portable Generator
Brand Name : Mahindra Power
Certification : CE Certified, ISO 9001:2008
Condition : New
Output Type : AC Single Phase
Frequency : 50 Hz
Warranty : 1year
Cooling System : Air Cooling
Automation Grade : Semi Automatic
Noice Level : Silent
Product Power : 1-5kw, 10-15kw, 100-250kw, 20-25kw, 25-50kw, 250-500kw, 5-10kw, 50-100kw, 500-750kw, 750-1000kw
Country of Origin : India
Application : Industries, hospital, hotels, high rise building
Rated Voltage : 240 Volt & 415Volt
Rated Current : 5 & 15Amp
...moreMahindra Diesel Generator Sets
01 Set(s) (MOQ)
We are authorized dealer of mahindra diesel generator, range starts from 5 kva to 500 kva. engine model15ld4401125 gr 2185 gm2205 lsgm gross power(100%) bhp 9 12 18 20 speed rpm 3000 1500 1500 1500 cooling system air cooled liquid cooled with radiator aspiration natural natural natural natural no. Of cylinders 1 1 2 2 displacement cc 442 864 1365 1490 governing class a2 a1 a1 a1 alternator type brushless, singlethree phase, class h voltage volts 230 230415 230415 230415 speed frequency rpmhz 300050 150050 150050 150050 control panel amf manual control panel – as per specific requirement application fuel tank capacity liters 21 42 100 100 battery capacity ah as per standard fitment acoustic enclosure length mm 1100 1600 1800 1800 width mm 850 850 900 900 height mm 895 1200 1250 1250 dg set approximate weight kgs. 225 700 750 750 note: above specifications are subject to change without notice due to continuous technical developments. All the above engine models conform to is 10000 specifications. Engine governing as per bs 5514. Alternator: reputed make conforming to respective is standards. Specifications 5 kva - 15 kva gensets 15 kva - 25 kva generators 30 kva - 62.5 kva dg sets 75 kva - 125 kva dg sets 125 kva - 200 kva gensets 250 kva - 500 kva gensets powerol dg sets catalogue pgtpl certification mahindra engines
...moreJINDAL'S AVC- STBILIZERS
We are authorized dealer of jindal's automatic voltage controller (stabilizer- linear technology). Product range- 30kva to 2500kva (balanced & unbalanced type)
...moreThree Phase Servo Stabilizer
01 Piece(s) (MOQ)
We are offering three phase servo stabilizer. Single phase description:- input:- 170v to 270v 1 phases, 2 wires, 50hz, unbalance. Out put:- 230v ± 1%, 1 phase, 50hz, un balance. Cooling:- air cooled. Controls:- auto manual. Specifications:- overvoltage & under voltage trip by means of contactor short circuit protection by mcb, analog voltmeter to see ip & op voltages analog ammeter to see load currents, built in control card compatible circuit built in single phase preventer. Op voltage adjustment: ± 5 v by means of potentio meter indications:- mains on, op on , ov, uv single phasing trip. 3 phase description:- input:-320v to 470v 3 phases, 4 wires, 50 hz, unbalance out put:-415v ± 1%, 3 phase, 50hz, balance cooling controls:-airoil cooled specifications:-overvoltage & undervoltage trip, shortcircuit & overload protection by mccb voltmeter to see ip & o p voltages. Ammeter to see load currents built in generator compatible control card circuit built in single phase preventer op voltage adjustment:- ± 10 v by means of potentio meter. Indications:-mains on, op on , ov, uv single phasing trip
...moreStabilizers
01 Piece(s) (MOQ)
We are offering stabilizers. Single phase description:- input:- 170v to 270v 1 phases, 2 wires, 50hz, unbalance. Out put:- 230v ± 1%, 1 phase, 50hz, un balance. Cooling:- air cooled. Controls:- auto manual. Specifications:- overvoltage & under voltage trip by means of contactor short circuit protection by mcb, analog voltmeter to see ip & op voltages analog ammeter to see load currents, built in control card compatible circuit built in single phase preventer. Op voltage adjustment: ± 5 v by means of potentio meter indications:- mains on, op on , ov, uv single phasing trip. 3 phase description:- input:-320v to 470v 3 phases, 4 wires, 50 hz, unbalance out put:-415v ± 1%, 3 phase, 50hz, balance cooling controls:-airoil cooled specifications:-overvoltage & undervoltage trip, shortcircuit & overload protection by mccb voltmeter to see ip & o p voltages. Ammeter to see load currents built in generator compatible control card circuit built in single phase preventer op voltage adjustment:- ± 10 v by means of potentio meter. Indications:-mains on, op on , ov, uv single phasing trip
...moreDg Set
We are offering Dg Set
generator acoustic
We are offering generator acoustic
open dg set
We are offering open dg set
Be first to Rate
Rate ThisOpening Hours