Y Type Strainer
Get Price Quote
We are leading Manufacturers, Exporters And Suppliers of Y Type Strainer. Y Type Strainer is designed for long service under the exact conditions created by high temperature and pressure. Installation of the Y Type Strainer before any automatic equipment will insure trouble free service and avoid costly repairs or replacements. For exceptionally fine straining, we offer Y Type Strainer with perforated screen lined with related wire mesh. Specifications Pressure, Temperature Rating : 50kg/cm2, 300deg C M O C : CS, SS, Hastelloy, Inconel, Duplex Stainless Steel, Super Duplex, Monel, Alloy20, Alloy400, Alloy625, Alloy825, Titanium, SS904L, Nickel, Gun Metal Size and Range : 15 NB to 1000NB and mesh from 10 to 6000microns Process connection : Any international standard
Spring Loaded Roller Apparatus
Get Price Quote
Spring loaded roller is capable of applying fixed load of 50N (5 Kgs) as per the standard when pressed. Caltech’s compact spring loaded roller can be held by hand firmly, easily pressed to get desired load and reduce human errors for applying constant pressure to provide best dust test results. Calibration adjustment is possible simply by adjusting nut. One single broad roller spring loaded roller along with dust test kit helps to accurately determine size and particle size of dust particles on steel surfaces prior to painting. Assure equal pressure for the complete tape to get best results. No maintenance required for this instrument.
Best Deals from Laboratory Apparatus
Ecg Machine
Get Price Quote
melting point
Get Price Quote
Salient Features : User friendly key board On line / Off line Printing facility Over 160 Test records can be stored Validation facility Facility to test unknown sample. For more clarity, stirrer speed adjustment on key board. Facility to store 10 Product names with their expected Melting Point. Model: VMP – PM : The instrument is designed to determine Melting Point of solids or Boiling Points of liquids, with high accuracy. The apparatus incorporates the latest type of MICROPROCESSOR BASED circuitry and is very simple to operate. The apparatus consists of a cylindrical Silicon Oil bath with heater. The sample is filled in a capillary and suspended through Teflon cover of the Silicon Oil bath. Similarly a Boiling Point tube with sample liquid can also be suspended through Teflon cover to determine Boiling Point of a liquid sample. The temperature of bath is maintained uniform with built-in magnetic stirrer. Tips of the sample filled capillary can be observed through magnifying lens on illuminated background of silicon oil bath. The Apparatus equipped with four lines alphanumeric informative LCD screen, which indicates PRODUCT NAME, BATCH NO. and SETTEMP.ACTUAL TEMP. Etc... The self-explanatory feather touch keyboard enables to set the desired program for heating Silicon Oil bath. Expected MELTING POINT of the sample is entered as Set Point. On pressing the ‘START’ key, the instrument automatically executes the program with ideal heating rates. The temperature of both starts rising fast in the beginning and automatically adjusts the rate of heating in suitable steps and 1I0;C/ min. towards the end of program. The unit is provided with Printer socket. Any 80 column dot matrix printer can be connected, it will print the header, product name, batch no. date and time of the test and rise in temp./min towards last 10I0;C. It also prints START OF MELTING POINT and END OF MELTING POINT. OVER 160 Test Records can be stored in the memory. ON line or OFF line printing is possible. Date-wise selection for printing is possible. An audio signal draws attention of operator for close observation of Melting Point towards the final reading. Melting Point can be clearly observed through Magnifying Lens and after reaching the actual Melting Point, the STOP key is to be pressed. At this stage Temperature will stop rising and displayed Temperature indicates completion of Melting Pont. If through oversight one fails to press ‘STOP’ key, the heating will stop automatically, after the Temperature reaches above set Temperature with TEST OVER message. The range of the Melting Point can also be determined by pressing RECORD TEMP. When RECORD TEMP, key is pressed start of Melting Range is indicated on the screen. Four such temperature values can be stored in the memory. On pressing the STOP key after complete melting of the sample , the heating is stopped. Start and end temperature of the Melting Range is then displayed. The instrument is also having facility for testing unknown sample. When UNKNOWN SAAMPLE option is selected the temperature will start rising at nominal rate so that is easy to observe the temperature at which the sample melts. Validation Program for the Standard Samples like Vanillin, Benzoic Acid and Caffeine is incorporated. Specification: Temperature range of the instrument is about 2º C above room temperature up-to 300ºC, readability + 0.1ºC, with accuracy + 0.1%. The unit works on 230 volts / 50 Hz, (0.750 KW Max.) A.C. mains supply. The Instrument is supplied with 200 ml of Silicon Oil and a box of capillaries.
comill sieves
Get Price Quote
FWI make under driven cone mill sieves are suitable for various international machine manufacturers like :Quadro,Glatt,GES,Cronimo, Kemutec, Frewitt(Coniwitt) Sieves suitable for all indian manufacturers. Sieves cab be tailor made to your specifications. In hole of S-series, R-series, G-series our sieves are suitable in machines like Quadro,Glatt,GES,Cronimo, Kemutec, Frewitt(Coniwitt) are notin anyway affiliated with filter woven india.
Distillation Unit Glass
6,500 Per Piece
1 Piece (MOQ)
Digital Melting Point Apparatus
Get Price Quote
Description : AMP 2A/2 melting point apparatus is an automatic, uncomplicated, and accurate process for determining a sample’s melting point. The starting temperature and heating rate are selected with a touch of the function keys . Simplyplace1 - 3 mgin to disposable sample tube and insert into instrument; the rest is automatic. When the melting point is achieved, a visual and audible signal is given and the temperature is displayed. The AMP 2A/2 makes use of the optical behavior of substances to detect their melting point, i.e., it measures the reflection of incident light in the crystalline state and the increase in light transmittance while heating. RS-232C interface capability allows connection to the CPR02 printer for GLP applications. Features : Photo Electric Detection. Large Backlite LCD display. RS-232 Interface. Measurement of 3 samples simultaneously (Optional). Display of initial and final melting points. Calculation of average value of initial and final melting points. Platinum resistor for the precise temperature measurement. Capillary sample tube as stipulated by pharmacopoeia. Software for computer interface. Application : Melting Point Apparatus measures the melting point of a substance i.e. the temperature at which the state of the substance changes from solid to liquid. The actual melting point is an indication of the purity of a substance and hence an ideal tool for the quality control of medicines, perfumes, dyestuff and other organic crystalline substances.
computerised low level laser therapy Apparatus
23,000 - 26,500 Per units
2 Pair (MOQ)
Fractional Distillation Unit
Get Price Quote
The distillation column designed to separate a homogenous mixture into its respective components. The highly efficient fractional distillation column can be designed in both standard and customized specifications. Fractional distillation is one of the highly efficient and accurate methods of distillation that has been used in industries since long back.
Test Sieves Circle
Get Price Quote
Filtering Sieve made with Joint Less Brass or Stainless Steel frame, with wide range of materials, sizes, shapes, microns & configurations used for evaporation, absorption, filteration or segregation, in mainly 8” 10” 18” 24” dia or as per customers requirements.
Heat Deflection / Vicat Softening Temperature Apparatus
Get Price Quote
The HDT/VSP instrument is used for determining the deflection temperature limit for specific application and comparing the heat softening characteristics of thermoplastic material at a constant load in oil upto 300 Deg. Co.cPlastic materials being heat sensitive in nature has a lot of bearing on its thermal environment for it's performance. Though their behaviour in thermal conditions is very complex some simple yeild tests are used to predict it's behaviour and performance in a given condition. "VICAT SOFTENING POINT" or "HEAT DISTORTION TEMPERATURE" is one of such yeild points very commonly employed with such demanding applications. Vicat test consist of penetrating a unit size indentor in a plastic surface with predefind load under constant rate of environmental temperaturerise. Heat distorsion test, as it is sometimes called, consistes of deflecting a simply supported beam of test material under similar heating conditions & with a predefined stress application.HDTTest for deflection temperature of plastics under flexural load. Heat distoration temp. is the temp. At which a sample deflacts by 0.1 inch. (2.5 mm). Standart test methods: ASTM D648, BS 2782 method 102, ISO R75.VSTVicat softening point is the temperature at which the needle penetrates 1 mm into the sample. Standard test methods : ASTM D1525, BS 2782 method 102D, ISO R306.
Reynold Apparatus
Get Price Quote
We are offering reynold apparatus. Open circuit type set - up reynolds's upper & lower critical numbers, velocities & to know the type of flow laminar turbulent simple in construction; storage tank with flow steadying arrangement dye bottle & capillary tube arrangement provided proper base frame is provided to mount the perspex tube to prevent rusting, tanks are made up of m.s. Sheet with powder coating.
Convection in Air Apparatus
Get Price Quote
Description :-For showing convection currents in air. Comprises of metal box, 220x100x100mm with a removable glass front, two chimneys and candle holder fixed to the base of the box beneath the left hand chimney.
Dissolution Test Apparatus
Get Price Quote
14 Nos. Easy to attach and detach `Press Fit’ wobble free Stirrer shafts with removable Paddle basket assembly.14 Nos. Unbreakable clear MOULDED Dissolution Vessels or Glass Vessels.Motorized sensor tray to measure individual vessel temperature, can be programmed to move as per set time.Equipped with very reliable maintenance free stepper motor drive for stirrers.Tablet dropping system.Sampling tray with 6 probes can be programmed to move as per set time.
Laboratory Furnace
Get Price Quote
Strainers
Get Price Quote
Various types of strainers like Y type, T type, Conical Temporary type, Basket type are available in various sizes and material of construction in fabricated and cast constructions. These pipeline strainers are designed as per free flow area and pressure drop allowance calculations as required for the application. They can be supplied with wedge wire element or perforated sheet with wire mesh.
Skiddometer
Get Price Quote
Description :-Skiddometer is an equipment designed to measure airport runway friction. The apparatus measures the maximum possible friction produced in the runway instead of only skidding friction.Salient Features: The equipment can be hauled behind an existing work vehicle. Care should be taken not to hard wire the unit with the vehicle. Some skiddometers are provided with Integrated Water System (IWS) for effective friction testing. IWS system can hold 325 gallons of water, that enables large areas to be tested without having to refill the water source.
Laboratory Apparatus
Get Price Quote
Gas Sampling Bombs that are specially designed to collect and store high pressure gas samples from the field & transport the same to laboratories. Superior in quality, these bottles pass through rigorous quality control tests and inspections to ensure maximum integrity and cleaning process for effective corrosion resistance. Designed as per exact industry standards and guidelines, the gas sampling bottles are available in different sizes and specifications. Application: Sampling Bombs permit the extraction of a sample from a remote process location and provide safe containment for storage and transportation to the laboratory for analysis. These cylinders are rated to 1800 psi at room temperature for liquids and gases. Some applications include hydrocarbon sampling in refineries, gas sampling in chromatography and condensate sampling in fossil-fuel and nuclear power plants. In similar applications, petrochemical facilities and gas processing plants utilize sample cylinders. Pressure surge accumulators or reaction vessels are other common uses for sample cylinders.
Laboratory Water System
Get Price Quote
Laboratory water system high pressure sitch is provided for ultrafiltrationso as to safeguard system. As soon as discharge pressure & pressure drop is more than 15 to 20% than normal then system will give alarm & if not attained within 5 min., the system will be tripped automatically.
salt spray apparatus
Get Price Quote
In the Salt Spray Apparatus Chamber articles are exposed to a mist of salt saturated air produced by spraying common salt solution into a closed cabinet. The articles are positioned so that they are exposed to the mist produced. The Apparatus consists of: 1)An acrylic mist chambers thatââ¬â¢s non-corroding. 2)A compressor for compressed air supply to chamber. 3)Atomizing nozzles for mist formation. 4)A specimen supporter. 5)Heater with temperature controller.
ECG Machines
Get Price Quote
We are offering Ecg Machines. Functions * Adopt high-resolution thermal printing system(8 dotmm), no need for any adjustments. Recording frequency: up to 150Hz. * Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.). * Full-digital design, anti-baseline drift, AC and EMG interference. * Adjust the baseline automatically, optimize the print setting and choose the rhythm leads. * In AUTO mode, finish all operation by pressing the button once, which improves work efficiency. * Adopt digital signal processing technology to get high-quality ECG waveforms via AC filter, baseline filter and EMG filter of ECG signal. * Auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, reduces the doctor's burden and improve work efficiency. * Multiply printing formats, including 2*6+1(rhythm lead), 2*6, 3*4, 3*4+1(rhythm lead), 4*3, 4*3+1(rhythm lead), 6*2, 6*2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc. * Display of 3612-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database. *Timing print can be set to every 123510203060 minutes. *Optional print setting, including "Print and save"(print waveform and save case), "Print no save"(only print waveform but not save case), "Save no print"(only save case but not print waveform). *Store up to 1000 cases, convenient for case review and statistic.
biomedical instruments
Get Price Quote
Our company wouldnt be where it is today but for the dedication and passion of our people united by a strong set of values.
ULTRASONIC ATOMISER
Get Price Quote
The Ultrasonic Atomiser uses Ultrasonic energy (Low/Medium) to generate low velocity, gentle spray unlike the conventional atomizing nozzle which depends on pressure & high velocity motion to shear a fluid into small droplets. The fluid (Liquid) is dispensed to the atomizing probe by either gravity or low-pressure small pumps & atomize continuously or intermittently as per requirement. The sample can be accurately delivered to the target area & over spray is virtually eliminated thus, resulting in material savings. The atomizer can runs continuously or be programmed to pulse On & Off. The rate of atomization depends within limits solely on the volume that is been delivered onto the atomizing surface & the frequency it operates. Typically higher the frequency, the lower the processing capability. With water the average droplet size is 50 microns and the minimum sample volume that can be effectively atomized is 2µl/sec. To optimize atomization, the viscosity below 50cps & solid concentration must be below 30%. The atomization of liquids containing long-chained polymer molecules is problematic, even in diluted form, due to highly cohesive nature of the material. Drop size is primarily a function of frequency, and the higher the frequency, the smaller the drop diameter, E.g. : frequency 20 kHz the drop size is 100 microns & frequency is 40 KHz the drop size is 50 microns. HOW DOES IT WORKS? The Ultrasonic power supply converts 50/60 Hz to frequency electrical energy. This electrical energy is transmitted to the piezoelectric transducer within the converter, where it is changed to mechanical vibrations. The ultrasonic vibrations are intensified by the probe and focused at the tip where the atomization takes place. The liquid travels through the probe, and spreads out as a thin film on the atomizing surface. The oscillating tip disintegrates the liquid into micro-droplets, and ejects them to form a gentle, low velocity spray. SUMMARY OF FEATURES OF ULTRASONIC ATOMIZER From micro-litres to litres – continuous or intermittent Dispenses material with virtually no over spray Pressure-less atomization – low velocity mist Low cost atomization probe replacement Minimal atmospheric contamination Virtually unclog gable Programmable operation Multiple probe operation No heating / No temperature rise TYPICAL APPLICATIONS Increase of humidity level Coating non-woven fabric, paper, etc… Laboratory spray drying Injection moisture into a gas stream Applying minute amount of oil, fragrance or flavour onto a product Injecting small volume of reagents into a reactor
hoods
Get Price Quote
VIKING™ offers a range of hoods made from rubber, neoprene or smoothskin materials. These may be attached to suits or sold as accessories such as semi dry hoods.
Basket Strainer
Get Price Quote
Minimum Pressure Drop Bigger Filteration Area Jacket
Digital Dissolution Test Apparatus
70,000 Per Piece
ESCR Apparatus
Get Price Quote
Ecg Machine
4,000 Per Piece
10 Piece(s) (MOQ)
ECG Machine 3-channel,6-channel,8-channel,10-channel,12-channel,specifications features,LCD screen,automatic ECG measurement and interpretation,large patient data storage, built-in thermal printer, built-in rechargeable battery
Conical Strainers
Get Price Quote
Conical strainers are installed in pipe line with its ring sandwiched between pipe flanges with due care for flow direction which is normally in to out. These strainers are fabricated out of stainless steel. Perforated plates & wire mesh or only perforated sheets.
Laboratory Furnace
Get Price Quote
We are offering laboratory furnace, our respected firm is widely applauded in the industry for providing a comprehensive collection of laboratory furnace.