voltage transducer
We Offer Voltage Transducer. This transducer converts a sinusoidal AC Voltage signal into an output signal for Single Phase Single Output (STE-A-2T), Single Phase Dual Output (STE-A-2TD), Single Phase Triple Output (STE-A-2TT) & 3-Phase 4-Wire (STE-C-2TT), that can serves several receiving instruments such as indicators, recorders, alarm units etc. The input Voltage is scaled down using a Voltage transformer T. The output of the transformer is rectified and filtered in a precision absolute amplifier A, incorporating integrated circuits. The amplified filtered output is proportional to R.M.S value of the sine wave input. The output is fed to a current converter 'C' to provide a load independent D.C. Current. Feature � Available in accuracy class index -0.2, 0.3, 0.5 & 1.0 � Withstands wide temperature variations. � VA burden on PT very low. - < 0.5 VA � Wide range of Input / Output to meet National / International requirements. � Comply to revised IEC 60688 (1997-10) standards. � Flexibility in auxiliary power supply requirements - A.C. / D.C. � Rugged and vibration resistant. � Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. � Available in dust proof sheet plastic enclosures suitable for Back panel / Din rail mounting. � Multiple outputs also available - up to 4. � High input / Output isolation - 4.0 KV.
...morevehicle security system
Tap Position Transducer
We Offer Tap Position Transducer. This transducer is used for measurement of the mechanical position of an external device or equipment. The mechanical position of the external device (Transformer Tap Change Gear) is converted to a resistance value with a potentiometer or a resistor network by a rotary switch arrangement. The output (which is a load independent current or voltage) is proportional to the ratio of the resistance value at a position (tap) to the maximum resistance value in the network [i.e. resistance value at the maximum position (tap)]. The output can be connected directly to indicating instruments, data transmission system, Computer systems or SCADA systems. Feature • High accuracy, withstands wide temp variation • Wide range of Input / Output to meet National / International requirements. • Complies to revised IEC 60688-(1997-10) standards. • Flexibility in auxiliary power supply requirements - A.C. / D.C. • Rugged and vibration resistant. • Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. • Available in dust proof sheet plastic enclosures suitable for Back panel / Din rail mounting. • Multiple outputs also available - upto 4. • High input / Output isolation - 4.0 KV. • Display Optional.
...moreSimulator Synchroscope
The simulator Synchroscope that We Offer is Ideal for Synchronizing the Generator with Grid Placed in Simulator. We Receive Repeated Orders for the Simulator Synchroscope We Bring Forth as It is Composed in a Very Precise Manner. Also, We are One of the Renowned Manufacturers and Suppliers of Simulator Synchroscope. composed Of one Eight Bit Digital to Analog Converter (dac)stepper Motorthree Reflector Sensorspower Supply (240vac, 50hz)bridge Rectifierfilterstep Down Transformerlinear Regulatorsa Voltage to Frequency (vf) Converter8 Bit Micro-controllertwo Analog Multiplexersfour Driver Amplifiers technical Specifications stepper Motor to Drive the Synchroscope Facia of Suitable Torque, Voltage & Current.four Inputs to the Driver Unit ( 0 or 24vdc),direction Control (0v= Clockwise 24vdc = Anticlockwise).start Stop of Stepper Motor(0vdc = Stop 24vdc = Start).0-10 Rpm 0-200 Rpm(0vdc = 0-10 Rpm 24vdc = 0-200 Rpm).accuracy = ±0.2rpm for 0-10rpm & ±2rpm for 0-200rpm.power On Power Off (0vdc = Power On 24v Dc = Power Off)three Outputs (potential Free) Indicating the Position of the Pointer On Either Sides of 12’0 Clock Position Within a Band of 600.indicates the Position of the Pointer Within 00 to –300,(contact Closed = Pointer Within 00 to –300 Position contact Open = Pointer Within 00 to 3300 Position).indicates the Position of the Pointer Within 00 to +300, (contact Closed = Pointer Within 00 to +300 Positio contact Open = Pointer Within 300 to 3600 Position).potential Free Contact for Sensing the Position of the Pointer At 12’o Clock Position.accuracy of Potential Free Contacts = ± 20.one Analog Input Signal (0 -10vdc) for Driving the Synchroscope Needle At Various Speeds in Start and Various Positions in Stop.provision for Positioning the Pointer At 6’0 Clock Position,after Mains 240vac Power is Switched Offinputs At 0 Levelfollowing Connectors are Provided for External Connections,three Pin Allied Connector for 240vac Supplyone 15 Pin D-type Connector for 3 Inputs and 3 Potential Free Outputsone 9 Pin D-type Connector for One Analog Input (0-10vdc)test Points are Given for Checking the Healthiness of the Unitauxiliary Supply : 240vac, ± 10%, 50hzinsulation Resistance of Greater Than 100 Mega Ohms Between all Points and Chassisvoltage Proof Rating Will Be 1.5kv Between Ac Supply Line and Chassis.environmental and Operating Conditions :normal Operating Conditions-temperature : 20 – 550 C, Relative Humidity : 5 -95 %
...moreReactive Power Transducer
We Offer Reactive Power Transducer. This transducer is used for measurement of Reactive Power for single phase (STE-A-4T) system as well as for 3-phase, 3-wire (STE-B-4T) system and 3-phase 4-wire (STE-C-4T) systems with balance and unbalanced load. They are suitable for measurement of both import and export of power. The output is a load independent DC current or voltage which is proportional to input power. The output can be connected directly to indicating instruments or to data transmission system. Feature • Available in accuracy class index - 0.2, 1.0 & 0.5 • Withstands wide temperature variations. • VA burden on CT/PT very low. - < 0.5 VA • Low internal consumption • Wide range of Input / Output to meet National / International requirements. • Comply to revised IEC 60688 (1997-10) standards. • Flexibility in auxiliary power supply requirements - A.C. / D.C. • Rugged and vibration resistant. • Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. • Available in dust proof sheet plastic enclosures suitable for Back panel / Din rail mounting. • Multiple outputs also available - upto 4. • High input / Output isolation - 4.0 KV.
...morepower line transducers
Used for Converting power Line Parameters Into Proportionate Dc Signals, the Power Line Transducers are Ideal for Energy Management Data Acquisition System. the Power Line Transducers are also Suitable for Telemetering, Supervisory Control, Data Acquisition (scada) for Process Control in Varied Industries Including Power, Cement, Chemicals, Steel, Sugar, Building Automation, Fertilizers and Others. types (for Ac & Dc) power Factordc to Dc Converterscurrentvoltagefrequencypowerapparentactivereactivesummation Amplifierenergy apparentactivereactivetemperature (rtd/thermocouple) features also Available in 19" Rack Mounting / Eurocard Formatmultiple Output also Available – Up to 4available in Accuracy Class Index - 0.1,0.2,0.5,&1.0low Internal Consumptionwide Range of Input / Output to Meet National / International Requirementscomply to Revised Iec60688-1 Standardsflexibility in Auxiliary Power Supply Requirements - Ac / Dcwithstands Wide Temperature Variationsva Burden On Ct/pt Very Low - < 0.5 Varugged and Vibration Resistantwithstands Seismic Test as per Iec 344-1974 for Nuclear Power Plant Applicationsavailable in Dust Proof Sheet Plastic Enclosures Suitable for Back Panel / Din Rail Mountinghigh Input / Output Isolation - 4.0 Kv
...morePower Factor Transducer
We Offer Power Factor Transducer. The STE-A-7T transducer converts the phase angle between current and voltage of a single phase or 3 phase balanced network into an output signal that can serve several receiving instruments such as indicators, recorders, alarm units etc. Feature •Available in accuracy class index - 0.5, & 1.0 •Withstands wide temperature variations. •VA burden on CT/PT very low. - < 0.5 VA •Wide range of Input / Output to meet National / International requirements. •Comply to revised IEC 60688 1997-10 standards. •Flexibility in auxiliary power supply requirements - A.C. / D.C. •Rugged and vibration resistant. •Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. •Available in dust proof sheet plastic enclosures suitable for Back panel / Din rail mounting. •Multiple outputs also available - up to 4 •High input / Output isolation - 4.0 KV.
...moreMultifunction Transducer
We Offer multifunction Transducer that Integrates Electrical Parameter Monitoring in Computerised Utility Monitoring System. Providing Electrical Parameters in a Serial Port, the Multifunction Transducer is Demanded for Energy Management System and for Varied Applications. Moreover, We are One of the Distinguished Manufacturers of Multifunction Transducer in the Domain. features wide Range of Auxiliary Supply.compliance to Iec 60688 is 12784dsp Based Designedprogrammable Ct Ratioprogrammable Pt Ratio16 X 2 Character Backlit Lcd Displaysoftware Being Upgradeableopen Source Communication Protocol.wide Range of Current and Voltage Input. technical Data input : 3 Ø, 4 Wire 3 Ø, 3 Wire, 1 Ø, 2 Wirevoltage : 0–150v Ac 0–300v Ac Phase to Neutral 0-300v Ac 0-600v Ac Line to Lineaux. Supply : 24v48v110v220v Dc or 110v220v Ac. (+15%)communication : Rs485, Modbus Protocol Address Settable On the Unitcurrent : 0 – 5 Amp.display : 16 X 2 Character Backlit Lcdmeasurements : Vrms, Irms ( Individual Phase and Average )active Power, Reactive Power, Frequency, Power Factor, Import & Export Energy (active & Reactive)accuracy : Class 0.5 for all Parameters Except Class 0.1 for Frequencysettings : ctr Ptr Settable Through Serial Port
...moreHumidity & Temperature Indicator.
We Offer Humidity & Temperature Indicator. HTI-01 is a unit, which provides an integrated measurement solution for HVAC control systems. The unit interfaces directly with a humidity sensor and temperature input provides local indication of Humidity & Temperature. Feature • Input 1 : 0-10V DC Humidity sensor proportional to 0 to 100% RH. Impedance > 100 Kilo ohm. • Input 2 : 0-10V DC Temperature sensor. Range 0 to 50oC. • Display : Two separate display for indicating Humidity and Temperature. • Resolution : 0.17 Rh & 0.1oC. • Accuracy : 1.0%. • Auxiliary Supply: 24V AC or 240V AC, 3VA max. • Dimension: 120mm x 210mm x 50mm
...moreGps Based Clock
The gps Based Clock that We Bring Firth is Used in Process Industries, Power Plants, Airports, all India Radio, Railway Stations, Doordarshan, Etc. for Synchronizing Time Data. the Gps Based Clock Can also Work Efficiently in the Absence of Satellite Signals By Using Rtc as Well as Oven Controlled Crystal Oscillator. specification master Clock Gps (optional Stand Alone Ocxo Based Unit)membrane Keypad for Configuration of Contactmultiple Slave Clock Drive Up to 1.2 Kmgps Time Synchronization to Pc, Lan Network (optional), Slave Clocks, Etcalarm Facility operating Voltage - 230 Vac, 50 Hzrs 232c, Rs485, Tcpip (optional) Interfacebuilt in Real Time Clockpotential Free Contact Output Pulse (1pps,1ppm, 1pph, 1ppd)time Date Display (lcd)op Selection, Periodicity, Pulse Width - Local Time Setled Indication of Status (gps Healthy Modes of Operations Etc.)back Up Time Using High Accuracy (0.1, 1ppm) Oscillatorsdimension: 483mm X 355mm X 560mm digital Slave Clock remote Setting for Time Manual Time Set Through Remote Control (optional)ceiling Wall Mountingtime Synchronization with Master or Gps (in Standalone Mode)stand-alone Network Modeoperating Voltage - 230 Vac, 50 Hzsignal Driving Distance 1.2 Km Through Twisted Pair Communication Cable Used for Rs485 Linktime Display in Hh:mm:ss, (hh:mm)display Seven Segment Red (4" & 2" Digit, Any other Please Specify)multiple Slave Clock Connectivity, Extended Slave Clock Drive
...moreembedded systems
Digital Slave Clock
We Offer Digital Slave Clock provide large display of time in hours minutes and seconds. They are synchronized to the central controller by the time broadcast received on a RS 485 serial port. The Slave clocks have a built in high stability crystal oscillator provided for back up in case of absence of serial communication. The display is Seven Segment LED display of 4” height, the brightness of which is controllable. Provided key board for setting for Free running and direct setting of clock. The power supply for the clock is derived from the Mains supply. ( 240 V AC.) Feature •Time Synchronization with Master or GPS (in standalone mode). •Time Display in HH:MM:SS, (HH:MM). •Display Seven Segment Red (4” & 2” Digit, any other please specify). •Signal Driving Distance 1.2 Km through twisted pair Communication cable used for RS485 link. •Multiple Slave Clock connectivity, extended slave clock drive. •Stand-alone Network mode. •Remote setting for time Manual Time set through Remote Control (Optional). •Ceiling Wall mounting. •Operating Voltage – 230 VAC, 50 Hz.
...moreDigital Panel Meter
We have Available with Us Digital Panel Meter Using Which One Can Easily Measure Basic Ac and Dc Electrical Parameters. the Digital Panel Meter is User Friendly in Nature and Has a Huge Demand all Across the Globe. Besides, the Digital Panel Meter is Used in Various Substations and I Industries. range Covered ammeterenergy Meterfrequency Metervoltmeterpower Meter specifications display : 4 1/2 Digits or 3 1/2 Digits Seven Segment Led Displaymeasurements voltage : Ac / Dcrange : 500v7300v/200v/20v/2vcurrent :ac / Dcrange : 10a/5a/2a/1a/0.1aisolation1.5 Kv / 1 Minute Between Line,Neutral & Earth500v Ac / 1 Minute Between Inputs & Earthinsulation Resistance At 500v Dc > 100 Between Above Terminalsv. Aux. Supply : 24v Dc / 48v Dc / 100-300v Dc / 85-265v Acspeed : 4800 / 9600 /19200 / 38400 Bps.size : 96 X 48 X 85 Mm Environmentaccuracy : +0.5% of Fsd.rs 485 : Mod Bus Rtu Protocol.communication : rs-485 ( 2 Wire )operating Temp : 0 55°c
...moreDc Isolator Transducer
The dc Isolator Transducer offered By Us Helps in Converting Input Dc Voltage to Voltage At Output with the Usage of Galvanic Isolation. Moreover, These Dc Isolator Transducers are Used to Interface with Rtds and Thermocouples. Besides, the Dc Isolator Transducer is Demanded for Telemetering, Control Systems and Computers Where It is Used as An Isolating Element and An Amplifying Element. features line Resistance Compensation for Rtd with 3wire 4 Wire Connectiontc & Rtd Output Linearised to Be Proportional to Temperaturehigh Input Output Isolations - 1.5 Kvambient Junction Compensation for Tcavailable in Accuracy Class Index - 0.1, 0.2, & 0.5withstands Wide Temperature Variationslow Internal Consumptionwide Range of Input Output to Meet National International Requirementsrugged and Vibration Resistant.available in Dust Proof Sheet Plastic Enclosures Suitable for Din Rail Mounting technical Data measuring Range : 0-1.2ln(or Vn)fortc : 0° to 500ac or as Specified By Customersfor Rtds (pt 100) : 0° to 300°c or as Specified By Customersrated Input : 1 2.5 5 10 20 4-20 Ma60 Mv to 600 V Dctc : -10mv to 60mvrtds : 40 to 300internal Consumption :
...moreDc Energy Meter
The dc Energy Meter provided By Us is Used for Measuring Electrical Energy Consumed By Multiple Loads that are Connected to D.c. Voltage Source. Furthermore, the Dc Energy Meter is Ideal for Measuring the Drop of Voltage Across Current Shunt, Input Voltage and Observing Current, Voltage, Kw & Kwh with the Usage of Push Button Switches. features 7 Digit Lcd Display of Kwhuser Selectable Shunt Ratingreset of Kwh for Every Channel Protected By Passwordindividual Channel Can Be Enabled or Disabledshunt Can Be Placed Either in +ve or -ve Side of the Dc Power Sourceenergy Values & Settings Retained After Power Failureremote Monitoring of Parametersdisplay of Dc Current, Voltage, Power (kw) & Kwhr for 7 Channelssoft Calibration – No Trimpotsoptional Real Time Clockoperates from Battery Being Monitored (optionally It Can Be Operated from a Different Auxiliary Power Supply)optional- Rs 485 Modbus Link for Pc Connectivitydata On Modbus Protocol Can Be in “integer” Format or Ieee 754user Friendly Lcd Display Messages technical Specifications electrical input Voltage : nominal Voltage Range12v (10 to 19v), 24v (20 to 38v)48v (40 to 76v), 96v (80 to 152v)110v (90 To175v), 220v (180 to 350v)input Current : nominal Shunt Value 75mv (50 to 100)operating Range 5mv to 100mvauxiliary Supply : same as Input Voltage or Optionally Any Voltage Noted in the Voltage Range Abovemeasurement : 7 Channel Dc Kwhraccuracy : +/- 1% (10 % to 120 % of Range)resolution : 0.1 Kwhrindication display : 16 X 2 Character Backlit Lcd Character Size 2.95 X 4.35mmdisplay Parameter (four Channels)kwhr -xxxxxx.xcurrent- Xxx.xpower ( Kw) -xx.xvoltage -xx.xconfigurable Parametersshunt Rating- 75 Mv = 10 to 1000 Ampbaud Rate -9600 to 19200device/ Unit Address -01 to 255calibration for Each Channel and Reset of Energy Count Provided with Password Protectionprotection : Reverse Input Polarity Protectionisolation between Aux-supply and Electronics: 500 V Dc for 1minbetween Current (shunt) and Input Dc Potential: 500 V C for 1 Mincommunication rs 485 2 Wire Communicationprotocol Modbus Rtu Integer, or Ieee 754baud Rate : Settable Either 9600 or 19200address : Settable 01 to 255data Retention: Energy Values and Settings Retained After Power Failurecalibration: Soft Calibration Through Softwarereal Time Clock (rtc) : Optionalpower Consumption : < 2 Wattsecurity password for Editing of Settingspassword for Calibrationenvironmental normal Operating Conditions. Temperature: Operating Temperature: 10 C to 55 C relative Humidity: 55% to 85%.dimensions housing : Plastic or Metal Housing 96 X 96 X 65 Mm (cut Out 92 X 92 Mm)
...moreDc Earth Leakage Relay
5,000 - 9,000 Per piece
2 Piece (MOQ)
Offered By Us is dc Earth Leakage Relay that Works By Measuring Differential Current Between Both the –ve and +ve Current Carrying Conductors. the Dc Earth Leakage Relay Provided By Us is Supplied to Far Flung Areas of the World Through the Wide Spread Network of the Company. used For localizing and Detecting Earth Leakages in Dc Power Systems specifications sensor: back Panel Mountable with An Opening Provided for Passing the -ve and +ve Conductors Through. Size of Opening is 50 Mm Dia (smaller Dia Sensors are also Available )detectorsensing Range : + - 5 1020 Ma Selectable By Shorting Terminals On the Unit indication : +ve Leak, -ve Leaktime Delay : 10 Seconds for Turn On and Turn Offauxiliary Supply : 20 to 80 V, or 80 to 300 V Acdctrip Output : 1 Changeover Contact On Leakage Exceeding Set Valuecontact Rating 5 a 230v Ac 30 V Dcreset : auto or Manual Selectable By Shorting Terminals On the Unitmanual “reset “ Button Provided On the Unit dimensionssensor : 113mm X 30mm X 105mm ( 50mm Opening ), 87.5mm X 26mm X 81mm (20 Mm Opening )detector Unit : 70 Mm X 100 Mm X 110 Mmaccessories : cable Between Detector and Sensor of 2 Metre Length
Country of Origin : India
Color : Blue
Condition : New
Current Type : DC
Mounting Type : Base Mounting
Power Consumption : 2W-5W
...morecurrent switch
The current Switch that We Deal in Monitors Loads in the Systems of Building Automation. the Current Switch Senses the Current for Monitoring the Power Condition. the System Lights to Indicate Closed Switch with Led. with Easy Adjustments, the Current Switch is Popular Amidst the Clients. features input / Output Isolation Via Current Transformertrue Digital Switching and No Leakagecompact Sizesolid-state Reliabilityself-powered and No Insertion Losseasy Field Adjustment with Status Led'ssolid, Reliable Mounting Method specifications insulation Class : 600vresponse Time: < 200 Ms Temp. Rating -25 to 60° C ( 0 to 150° F)wiring Connections : split Core - Screw Terminals (14 to 22 Awg)hysteresis : < 2% Fs Maxoperating Temperature : 0 to 70° C (32 to 160° F) Power Supply None-self-poweredset Point Range : 1. 5-200 for Sp Modelsjumper Amp-turns : low (none) 1-10, Medium 10-50
...morebattery monitors
Battery Charge Monitor BCM-01
We Offer Battery Charge Monitor BCM-01 is a micro controller based unit, which is used for monitoring the charge level of stationary battery systems. This unit measures the voltage drop across a shunt through which the battery is connected to the charger and the load. The unit displays the charge remaining on the battery in terms of Ampere- Hour (AH) capacity as well as remaining time for which the battery can supply rated current. The unit incorporates precision analog and digital circuits and has the following features Feature Ø A settable low charge alarm Ø Display of the charge on the battery as AH and Remaining time for complete discharge. Ø Field Setting of the Rated battery capacity in AH. Ø Field setting of the shunt rating. Ø Remote Indication of fully charged Battery condition. Ø Soft calibration – no trimpots. Ø Optional- RS 485 Modbus link for PC connectivity. Ø Optional Ethernet connectivity for networking. Ø Operates directly from the battery being monitored. Ø User friendly LCD display messages. Ø Field setting of Battery efficiency.
...moreActive Power Transducer
We Offer Active Power Transducer. This transducer is used for measurement of Active Power for single phase (STE-A-3T) system as well as for 3-phase, 3-wire (STE-B-3T) system and 3-phase 4-wire (STE-C-3T) systems with balance and unbalanced load. They are suitable for measurement of both import and export of power. The output is a load independent DC current or voltage which is proportional to input power. The output can be connected directly to indicating instruments or to data transmission system. Feature • Available in accuracy class - 0.2, 0.5 & 1.0 • Withstands wide temperature variations. • VA burden on CTPT very low. - < 0.5 VA • Low internal consumption • Wide range of Input Output to meet National International requirements. • Comply to revised IEC 60688 (1997-10) standards. • Flexibility in auxiliary power supply requirements - A.C. D.C. • Rugged and vibration resistant. • Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. • Available in dust proof sheet plastic enclosures suitable for Back panel Din rail mounting. • Multiple outputs also available - upto 4 • High input Output isolation - 4.0 KV.
...moreActive Energy Transducer
We Offer Active Energy Transducer. This transducer is used for measurement of Active Energy for single phase (STE-A-8T) system as well as for 3-phase, 3-wire (STE-B-8T) system and 3-phase 4-wire (STE-C-8T) systems with balanced and unbalanced load. This is fully solid-state instrument, which can be interfaced directly with Digital Data Acquisition System. The Input Voltages and currents are galvanic-ally isolated and suitably scaled down by transformer T1, T2 etc. Depending on the system one or more electronic multipliers M1, M2 etc are used. The multiplying circuit used is the popular time division multiplication method. The implementation of the TDM technique as designed by SITU, makes the accuracy of multiplication dependent only on a few precision resistors and a low temperature coefficient reference zener.The outputs of the multipliers are summed up and fed to a precision voltage to frequency converter F. The frequency converter converts the input voltage to a proportional frequency by using “State-of-the-art” charge feedback technique. The output of the frequency converters in the form of pulses, which is then divided by using digital technique, the division factor depending on the input transformation ratios. The divided pulse rate is then output either as an open collector output or as a potential free contact. Feature : • Available in accuracy class index - 0.5, 1.0 & 2.0 • Withstands wide temperature variations. • VA burden on CT/PT very low. - < 0.5 VA • Low internal consumption • Wide range of Input / Output to meet National / International requirements. • Flexibility in auxiliary power supply requirements - A.C. / D.C. • Rugged and vibration resistant. • Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. • Available in dust proof sheet plastic enclosures suitable for Back panel / Din rail mounting. • High input / Output isolation's - 4.0 KV.
...moreac voltage transducer
We Offer Ac Voltage Transducer. The Voltage transducer converts a sinusoidal AC Voltage signal into an output signal that can serves several receiving instruments such as indicators, recorders, alarm units etc. The input Voltage is scaled down using a Voltage transformer T. The output of the transformer is rectified and filtered in a precision absolute amplifier A, incorporating integrated circuits. The amplified filtered output is proportional to R.M.S value of the sine wave input. The output is fed to a current converter 'C' to provide a load independent D.C. Current. Feature • Available in accuracy class index -0.2, 0.3, 0.5 & 1.0 • Withstands wide temperature variations. • VA burden on PT very low. - < 0.5 VA • Wide range of Input / Output to meet National / International requirements. • Comply to revised IEC 60688 (1997-10) standards. • Flexibility in auxiliary power supply requirements - A.C. / D.C. • Rugged and vibration resistant. • Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. • Available in dust proof sheet plastic enclosures suitable for Back panel / Din rail mounting. • Multiple outputs also available - up to 4. • High input / Output isolation's - 4.0 KV.
...moreVehicle Tracking Systems
transducers
Be first to Rate
Rate ThisOpening Hours