Water wall cum Combustion Boilers
Water wall cum Smoketube Fluidized Bed Combustion Type Boilers Type : Three pass, horizontal, radiation chamber cum shell type, Fluidized Bed Combustion with screw feed system conforming to the latest revisions of Indian Boiler Regulations (IBR). Capacity : 1000 to 15000 kg/h ( F & A 100° C ) Working Pressure : 10.54 / 14.5 / 17.5 kg/cm2 (g) and above. Fuel : Coal, lignite, petcoke , firewood, bagasse, husk / other agro
...moreSolid Fuel IBR Steam Boilers
Packaged Type fully wet back solid fuel IBR Steam Boilers Type : Three pass, horizontal, smoketube, fully wetback, packaged boiler, conforming to the latest revisions of Indian Boiler Regulations (IBR). Capacity : 600 to 10000 kg/h ( F & A 100° C ) Working Pressure : 10.54 / 14.5/ 17.5 kg/cm2 (g) and above. Fuel : Coal, lignite, petcoke , firewood, bagasse, husk / other agro waste etc.
...moreOil Solid Fuel Small Boiler
Type : Horizontal 2 Pass / 3 Pass - Oil / Solid Fuel fired Small Industrial Boiler Capacity : 400 to 850 kg/h (F&A 100° C) Working Pressure : 7 kg/cm² (g) Fuel : Oil / Coal / Wood / Bagasse / Agro Waste ( Husk ) Furnace : Internal Furnace
...moreOil Gas IBR Steam Boilers
Type : Three pass horizontal, smoke tube, fully wetback, packaged boiler, conforming to the latest revisions of Indian Boiler Regulations. (IBR) Capacity : 1000 to 25000 kg/h F & A100º C Working Pressure: 10.54 / 14.5/ 17.5kg/cm2 (g) and above. Fuel : LDO / FO / Gas / Dual Fuel (Oil cum Gas) Thermal Efficiency : 88 ± 2 % without heat recovery unit and 92 ± 2 % with heat recovery unit based on NCV of fuel oil. Burner : Fully automatic pressure jet (high - low / stepless modulation ); indigenous / imported burners. The combustion chamber (furnace) forms the first pass in which the fuel is atomized, combusted and radiant heat transmitted to the water contained in the shell, submerging the furnace, reversing camber and smoke tubes. The hot flue gases are diverted through the internal reversing chamber (wetback) and subsequently to the second and third pass of tubes transferring the convective heat to the boiler. The boiler is of Class 1 fusion-welded construction. Burner & Boiler Controls The burner programmer ensures an automatically controlled programme for start-up, firing, shutdown and restart of the boiler based on measurement of boiler pressure. Necessary interlocks are provided for safe operation. The water level is controlled through Mobrey type dual controller which is a magnetically operated water level controller of vertical type in a float chamber and is externally mounted on the boiler. One switch of the dual controller operates the electric feed pump on/off. The second switch cuts out or locks out the burner in case of low level of water and at the same time operates a low level alarm. The boiler is provided with one high pressure cutout switch and one additional pressure switch for high/low, or continuous modulation of operation. Salient Features MAXITHERM has adopted the modern concept of eccentrically located furnace with smoke tubes arranged in a staggered manner on one side of the furnace. The front and rear tubes and the furnace are accessible for inspection and maintenance. Generously proportioned furnace with large furnace volume ensuring; Maximum possible absorption of radiant heat. Avoidance of flame impeachment on the rear of the furnace. Prevention of clinker formation. Enhanced life of furnace. Adequate water and steam spaces enable the boiler to meet fluctuating loads with out appreciable fall in the operating pressure. This also ensures prevention of priming, foaming and carryover of the boiler water into steam pipelines and further ensures steam with high dryness fraction. The eccentrically located furnace has the following advantages :- Easy accessibility to the outer surface of furnace for inspection and scale removal. Possibility of providing single smoke box, which when opened makes all smoke tubes accessible for cleaning. The burner is mounted directly in font of the furnace, facilitating opening of the front door to clean the tubes without disturbing the burner.
...moreMembrane Wall cum Steam Boiler
Membrane Wall cum Smoke Tube Type Steam Boiler. Type : Horizontal 3 pass design of Membrane Wall-cum-Smoke Tube Type Capacity : 1000 kg/h to 15000 kg/h ( F & A 100° C ) Working Pressure : Std. 10.54 / 14.5 / 17.5 kg / cm² (g) & above Fuel : Coal, Lignite, Wood, Rice husk, Petcoke, Briquette, Bagasse etc.
...moreCoil Oil GasFired Steam Boilers
Coil Type Oil/Gas/Oil cum Gas Fired Steam Boilers Type : Four pass, vertical, watertube (coil type), packaged boiler, which are presently outside the purview of Indian Boiler Regulations. Capacity : 100 to 1000 kg/h Working Pressure : Standard pressure up to 15 kg/cm2 (g). Higher pressures are possible. Fuel : HSD / LDO / FO / Gas / Dual Fuel (Oil cum Gas) Thermal Efficiency : 88 ± 2 % based on NCV of Fuels SPECIFIC ADVANTAGES: Presently exempted from Indian Boiler Regulations No qualified or full time boiler attendant is required. Full pressure steam within three minutes from cold start. Compact. Minimum space and weight Explosion-proof: Fully automatic after a manual sta rt, t High efficiency-low operating cost. High velocity Burner: Pressure atomized type for positive clean performance. Capable of meeting fluctuating loads. Steam is produced as it is used.