Fully Stainless Steel. Semi Automatic & Fully Automatic models. Double safety with safety valve & automatic digital controller. Automatic low water level cut-off device to protect heaters. Single, Double & Triple walled (Jacketed) Features Top end model for sterilization of all critical application with exact reproducibility. Semi / Fully Automatic operation. Unique Double / Triple Walled Design. Heavy Duty Jacket. Automatic Purging of Steam. Micro Processor based precise controlling. Set pressure & selected temperature are attained. Timer starts count down, after attaining set temperature. Audio alarm (Buzzer) gives signal of completion of sterilization cycle after set time is over. Recording of online cycle - optional.
...moreultrasonic cleaning tanks
Use high frequency sound waves to create bubbles for loosening and removing dirt, scale and other impurities from Industrial parts washers remove grease, soil, oil, abrasive dust, blast debris, swarf, paint, corrosion or other contaminants from the surfaces of components exiting a production line.
...moreUltrasonic Cleaner
Use high frequency sound waves to create bubbles for loosening and removing dirt, scale and other impurities from Industrial parts washers remove grease, soil, oil, abrasive dust, blast debris, swarf, paint, corrosion or other contaminants from the surfaces of components exiting a production line. High efficiency ultrasonic make the most modern cleaning system possible An ultrasonic cleaner relies on a process called cavitation to gently and thoroughly clean the surface of your parts. An ultrasonic transducer attached to the cleaning tank transmits high frequency (30 khz) sounds into the cleaning solution. During the low pressure stage of each sound wave tiny bubbles form and grow. During the high pressure stage these bubbles collapses, removing dirt, rust and other contaminants. This cleaning action can reach any exposed surface, even into deep crevices. Application of Ultrasonic System Ultrasonic cleaning and vapour rising, Continuous vapour rising & Re- circulation. 2/3/4 stage cleaning and vapour degreasing system ideal for in-line operation. Removing oil, grease, buffing, compounds etc. High productivity solvent loses minimal compact designs. Some of typical Manufacturing soils and coating removed by this modern method are: Waxes, Silicon and Cutting Fluids, Heat scale and Burnt-on Deposits. Photo-Resist, Lacquer, Shellac and Print. Flux Residues, Resins, Asphaltic Materials, Adhesives and Gum.
...moretable top sterilizer
Features Table top front loading Fully automatic micro-processor based control Sterilization chamber made up of thick stainless steel sheet, tested to high pressure & external body powder coated. Digital timer both for wet & dry cycle. Auto drain of water to reservoir tank & also condensation of steam. Alarm after the total command is completed. Total Cycle time – 15 minutes
Capacity : Operation
Capacity : 17 litres
Voltage : 230 V
...moreSingle Drum Autoclave
body & lid made from stainless steel. size 12" dia x 14" deep. silicone rubber gasket. two safety valves. s. S. Pressure indicator gauge. s. S. Steam release valve. s. S. Drum stand electrically operated on 220 / 230 volts a. C, 50 hz cycles. i.s.i. Mark heating elements 2 kw non electrical models for use with stove / gas also available.
...moreSemi Automatic Rectangular Autoclave
705,000 Per Piece
Automation Grade : Semi Automatic
Material : MS
Brand Name : Modi
...moreSEMI-AUTOMATIC RECTANGULAR AUTOCLAVE
Centralised Control Point Multi-port operating valve, control for the entire cycle of the operation. Permits two exhaust speeds, fast & slow. Easy to read compound gauge for the chamber and pressure gauge for the jacket. Smooth operation. Safety Features Self locking safety door cannot be opened while chamber is under pressure. Gauge glass tube with automatic closing safety valve. Heat resistant SILICONE door gasket. Pressure switches ( on electric models ) economise power consumption. Low water protection system, to protect the electric heaters. Temperature gauge/Digital temp, indicators / controllers (optional) Vacuum breaker / dryer. Safety valve for the Jacket / boiler. Hydraulically test to 2.5 times the designed working pressure. Powerful ejector for drying. Insulated with resin bond fiber glass wool covered with M.S. / S.S.304 sheet Construction: Chamber & Jacket - The material used for chamber is of heavy duty 304 /316 L grade stainless steel and jacket S.S.304 / M.S. (Boiler Quality) Doors - The doors are constructed of heavy duty M.S. (Boiler Quality) / 304/316 grade stainless steel, both single and double door models are available. Piping - The pipes and fittings are of stainless steel and brass. The valves are ball type. ( manually) and pneumatically operated (automatic ) Mounting - The Sterilizer can be supplied in one of following mounting alternatives: Built in wall mounted , A flush mounted panel to isolate the sterilize side from the Non sterile side, Free Standing with 8cwithout cabinet. Panel - All Sterilizer are fitted with powder coated /stainless steel panels. Special panel design can be supplied according to customer requirements (optional) The Sterilizer is heated by steam. The steam can be supplied from the building is central source, an electric stainless steel steam generator or a combination of the two system, Clean steam can be supplied using a pure steam generator. Pull-out trays/carriages and transfer trolley are available to assist with the loading and unloading process. The loading carriage are made of stainless steel and come with adjustable shelves (extra shelves are optional) The transfer trolley is made of mild steel/stainless steel (optional) and moves on four heavy duty castors including foot brakes (optional)
...moreSEMI-AUTOMATIC CYLINDRICAL AUTOCLAVE
The Autoclave operates with saturated steam as the sterilization agent, working at pressure in the range of 0-32 p.s.i. (2.2 kg) and temperature in the range of 105`C to 137` C. Special temperature setting are available on request. The sterilization method substantially shortens the sterilization cycle,achieved by evacuating the air with a powerful ejector / vacuum pump,combined with steam pulsing.A 0.2 micron sterile air filter is provided to filter the air, which equalize the vessel pressure after the drying cycle. `MODIS`offers a large range of Sterilizer models from Standard 200 liter to 2000 liter size, as well as varied chamber dimensions according to the specific use and nature of Product requirements. Standards The sterilizers are manufactured as per I.S.I codes and bearing I.S.I Mark No. IS: 3829, Part-I & II endorsing the highest quality.
...morerinser
Model Number : MER-40
Rectangular Autoclave
Multi-port operating valve, control for the entire cycle of the operation. Permits two exhaust speeds, fast & slow. Easy to read compound gauge for the chamber and pressure gauge for the jacket. Smooth operation.
...moreHeat Sealing Machine
Features This Continuous Band Sealer with conveyor is suitable for small bags packaging and adopts electronic constant temperature control system and speed adjusting transmission mechanism. It can seal plastic films of various materials. Such as PE , PP , Aluminum foil. It is for sealing any virgin plastic material bags or for Multi – filament laminated Bags. It can be used for Vertical as well as Horizontal conveyed Bags. It has speed control, temperature control, height & side-wise adjustments......etc.
Temperature Range : 0-300°C
Model Number : SF – 150 LW
...moreGAUGE CUTTING MACHINE
The low profile base-plate drastically reduces fabric distortion and drag. The close fitting wing of the base-plate easily slips under the bottom ply without catching or snagging the cloth. The motor cooling fan dissipates heat build-up and directs the hot air-flow away from the operator. Operating handle and lever are postioned for maximum convenience. Blade can be sharpened by the automatic sharpening unit only when lever is pressed down, ensuring safety. Features This MODIS Octagon- shaped high speed steel knife and Carbide-tipped lower blade gives the finest, smoothest cut, while using on Cotton, Hosiery, Jute, felt, Rubber, Silk, Canvas, Nylon, Coir-Mat etc. This high-power motor, while providing an excellent cutting power, is kept cool by its technologically advanced Air Guide System Helping you save on power and money. Rollers provided under the base plate for easy maneuverability to cut straight or curves. Emery Stone has been fitted on the machine for sharpening of the moving blade which gets activated at the press of a button. 3 Ball - Bearings Provided for Smoother Operation.
...moreEto Sterilizer
Chamber SS 316L Size 12 X 12 X 54 inches ( 127 ltrs ) (4.5 cu ft)Chamber Operating Pressure Negative pressure cycleChamber Testing pressure 1.5 Kg/cm2 Door SS 304L Gasket Silicon Gasket (10/12 mm special section ) Outer cover Factory Finished (Poly-coated) SS / Powder-coated MS Heating Heaters on all sides of the Chamber for uniform heating throughout the load. Temperature Sensor For accurate measuring and controlling of Temp. in thechamber Operating Temperature Maximum: 65°C (chamber) RH% Sensor For measuring and controlling the humidity of the chamber Pressure Transmitter For measuring and controlling the pressure-vacuum thatthe load is subjected to during removal and charging of Gas. All fittings on the machine SS 304 Safety Valves SS 304 Humidification: special steam injector system to maintain humidity. Vacuum Special Noise-less Vacuum device provided for vacuum and aeration of the load. Automation Hardware: Touch Panel HMI, Industrial grade control and electrical Hardware Testing Pressure / Vacuum testing as per specified standards. (1.5 times the working pressure) Operation All functions are electro-pneumatically operated.
...morestainless steel hot air oven
Outer cabinet Stainless steel S.S. 304 Inner chamber stainless steel 316 grade Precise PID Temp. Indication & Control Silicon door gasket Supplied with SS Wire mesh shelves. Forced air circulation, by means of a motorized blower.
Application : Drying
...moreAutoclave Machine
The Autoclave operates with saturated steam as the sterilization agent, working at pressure in the range of 0-32 p.s.i. (2.2 kg) and temperature in the range of 105`C to 137` C. Special temperature setting are available on request. The sterilization method substantially shortens the sterilization cycle,achieved by evacuating the air with a powerful ejector vacuum pump,combined with steam pulsing.A 0.2 micron sterile air filter is provided to filter the air, which equalize the vessel pressure after the drying cycle. `MODIS`offers a large range of Sterilizer models from Standard 200 liter to 2000 liter size, as well as varied chamber dimensions according to the specific use and nature of Product requirements.
...moreautoclave drum
Body & Lid made from Stainless Steel. Size 12" dia x 14" deep. Silicone rubber gasket. Two safety valves. S. S. Pressure indicator gauge. S. S. Steam release valve. S. S. Drum Stand Electrically operated on 220 230 volts A. C, 50 Hz cycles. I.S.I. mark heating elements 2 kw Non Electrical Models for use with Stove Gas also available.