YS69P: Y-STRAINER WITH FLANGE CONNECTIONS
YS69P strainers are used in commercial and industrial applications, as well as for central water supply systems within the limits of their specifications. They protect systems against malfunction and corrosion damage resulting from the ingress of foreign bodies such as welding beads, sealing materials, metal cuttings and rust etc. This extends the life of the downstream system and prevents early failure. Special Features : Low flow resistance because of good dynamic flow design of body Powder coated inside and outside - Powder used is physiologically and toxicologically safe Stainless steel construction gives double sieve good corrosion resistance Large strainer mesh surface area provides high dirt acceptance capacity Sieve carrier ensures good sealing within housing Dirt particles or condensate in compressed air systems can be flushed out with blanking plug removed • Easy removal of sieve for cleaning
...moreXP88 / 89 : Ultrasonic (Ex) Level Transmitter
Provides two-wire 4-20 mA analog output Replaces capacitive rods, bubbler systems and sight gages Compact sensor with 2” deadband and beam width
Type : : Ultrasonic (Ex)
Accuracy : : 0.2%
Range : : 0 - 10m
...moreWS8910 : Weather Station
Small pocket knife shape & compact design Measures Air Velocity Jemp., Humidity, Windchill Temp., Dew Point Temp., Barometric Pressure, Heat Index and Altitude (8910only) Barometric pressure history bar chart display Wind units selectable: knt(knot), bf(beaufort), Fpm(feet per minute), mph(mile per hour), Ms(meter per second), kmh(kilometer per hour) Temp. Units °C/°F selectable Barometric pressure inhg, mbar, hpa selectable Display max. & avg.windspeed and quick response Easy to operate by only two buttons Auto power off to save power Tripod mountable receptacle
...moreWJL6000 : Refrigerant Gas Detector
Detect leaks of all halogenated refrigerants in any refrigeration, air-conditioning systems etc. The typical examples of halogenated refrigerants are: CFCs e.g. R12, R11, R500, R503 etc HCFCs e.g. R22, R123, R124, R502 etc HFCs e.g. R134a, R404a, R125 etc Blends e.g. AZ-50, HP62, MP39 etc Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas) Detect SF-6 in high voltage circuit breakers Detect most gases that contain chlorine, fluorine and Bromine (halogen gases) Detect cleaning agents used in dry cleaning applications such as perchloroethylene Detect halogen gases in fire extinguishing system Detects all kinds of halogenated refrigerants Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting Audible alarm and flashing light indicator upon gas leakage detected Inner precise IC with ultra-low consume circuit design, more stable, longer battery time Two color visual display of battery voltage Excellent sensor, high sensitivity, longer use time
...moreWH: Total Hardness Automatic Analyzer
Convenient maintenance 1. Easy tube replacement & disassembly 2. No defect due to simplified structure 3. Sample supply stop, alarm display 4. Alarm function for lack of reagents or sample Set function for analysis start,wait, end time Reagent 1ea & Low consumption (Available for 2-5 months) Convenient to operate Measurement data storage (500ea) Applications 1. Softner & softwater monitoring 2. Boiler water monitoring 3. Industrial boiler system
...moreWATER TEST K-100-TH : Total/Ca-Hardness Controller
On-line monitoring for Calcium (and Magnesium) in boiler water On-line measurement of Calcium (and Magnesium) after a softening cycle On-line analysis of Calcium (and Magnesium) in cooling water (e.g. at power plants) Feedback control of Calcium (and Magnesium) in water (lower/upper set points) With “alarm” output
...moreWater temperature sensor
The sensors employ precision interchangeable thermistors and RTD which are compatible with all the major building automation systems. Designed for temperature sensing in an HVAC and light industrial control applications Precision interchangeability eliminates the necessity for individual circuit calibration. Available in threaded PVC version with rugged weatherproof electrical box Data sheets for the standard items appear on the web at www.omicron-sensing.com Omicron is able to produce custom sensors in small volumeat standard sensor pricing There are several sensor element ranges to choose from, which guarantee compatibility with all popular DDC systems.The sensor elements are precision thermistors or platinum RTDs. Field calibration is not generally required. The probe is epoxy sealed to prevent moisture from migrating into the probe. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastics & metal manufacturing capabilities for custom housings as well.
...morewater level sensors
SL75 series standard level transmitter design with consummate encapsulation technology, the perfect assembly process insure the quality and performance of this series with high stability, high accuracy, leakage proof.
...moreWater Flow Switch
magnetically actuated flow switches are designed for positive detection of fluid flow through your equipment. These are suitable for water, kerosene, lubricating oils of low viscosity etc. These are available in 6 sizes, i.e.14”,38", 12", 34", 1" and 114" BSP. Suitable size may be selected from actual flow rate. Flow range covered is from 1 to 150 LPM. Fluid Flow in the System is seen through transparent tube
...moreVOC-8 : Indoor Air Quality Transmitters
The VOC-8... air quality sensors measure the concentration of multiple gases and odorous substances in the air with constant output. These substances, for example, may be tobacco smoke, kitchen vapors, human odors and unpleasant smells. In conjunction with a control device, it controls the fresh air supply according to the quality of the air in the room; as a result, energy savings can be made. In combination with a measurement device, it provides an indication of air quality in the room Special Features : IAQ multi-gas detection Continuous monitoring Long-life solid state sensor Easy sensitivity adjustment Room, 0-10 VDC signal Duct, 0/2-10 VDC, 0(1)-5 VDC, or 0/4-20 mA signal
Output : 4 - 20mA 0 - 10VDC
...moreVE100: HIGH ACCURACY DIGITAL PRESSURE GAUGE
VE100 is a micro-processor controlled, accurate and versatile digital pressure measuring instrument with integrated Max.-/Min.-function for calibration and testing purposes. The pressure is measured twice per second and displayed. The top display indicates the actual pressure, the bottom display shows the Max.- or Min.-pressure since the last RESET. VE100 has three operating keys. The left key is to turn the instrument on, to select the functions and the pressure units. The right key executes the selected function resp. unit or serves to display the Max.- and Min.-value.
Accuracy : : ± 0.075% of F.S
...moreVD100 : HIGH ACCURACY DIGITAL MANOMETER
VD100 is an Ultra Low Power Microprocessor controlled, accurate and versatile Digital Pressure Measuring Instrument. VD100 has state of the art customized large character display showing pressure in upto 8 Units, Low Batt, min, max. VD100 is very easy to use and you will never get lost in a multilevel menu. With 5 Digital LCD Display and battery life of more than 1000 hours (Continuous usage), VD100 is the most versatile portable digital manometer. Features: Light Weight High Accuracy upto 0.05% with Quick Response Large LCD Display Password Protected Calibration 5 Digit LCD Display with 8 Units
...morevav boxes
Omicron’s VAV Boxes are designed to provide a regulated flow of air to a specific area to maintain the desired dry bulb temperature for an overall level of occupant comfort. Special Features : Option of Single Skin / Double Skin Factory Calibrated VAV Boxes Cooling Only / Reheat / Fan Powered VAVs BACNET / LonWorksCommunication Internal Multipoint Averaging Velocity Sensor Shaft Indicator for Damper Position Factory Mounted Controller Can Monitor and Control CO2 Levels
...moreV5032A: REGULATING BALANCING VALVE
The hydronic balance is a significant requirement for the efficient operation of a hydronic heating or cooling installation. In an unbalanced system under or over provision of hot water to individual radiators or circuits can occur. Apart from the correct selection of radiator valves, regulation of individual circuits is also necessary and in some cases, such as in DIN 18 380, VOB part C, required by national standards. This requirement is met with V5032A Kombi-2-plus doubleregulating balancing valves The V5032A Kombi-2-plus is a variable orifice double-regulating balancing valve for the return with additional functions shutoff, draining and filling. Together with a V5012 Kombi-DP diaphragm unit the V5032A Kombi-2-Plus can be upgrated to an automatic balancing valve - even after the system has been taken into commission and under system pressureg. Special Features : Quick and easy measuring with SafeConTM measuring connections Dimensions DN15 to DN40 can be retrofitted with a Kombi-Diaphragm Unit High accuracy of pre-setting because of individual adjustment Robust valve body made of corrosion resistant red bronze Availabe in sizes up to DN80 Visible pre-setting dial with concealed pre-setting wheel Maintenance free spindle with double O-ring sealings PTFE-seat sealing
...moreV4: FLANGED BALANCING VALVES
The hydronic balance is a significant requirement for the efficient operation of a hydronic heating or cooling installation. In an unbalanced system under or over provision of hot water to individual radiators or circuits can occur. Apart from the correct selection of radiator valves, regulation of individual circuits is also necessary and in some cases, such as DIN 18 380, VOB part C, is required by national standards. This requirement is met with V4 Kombi shutoff and balancing valves. V4 Kombi have functions shut-off, pre-setting and measuring. Special Features : Balancing through stroke limitation with digital pre-setting and visible pre-setting indicator Suitabfe for inEquipped with 2 pressure test cocks for differential pressure measurement Non rising spindle with EPDM and EPDM O-ring sealing Pre-setting isn’t altered when handwheel is turned Regulation screw protected by protection cap PTFE seat sealing Valve cartridge and spindle made of cast steel Available in dimensions up to DN400
...moreUV-44-W: FORGED BRASS BALL VALVE
Application : Water AIR Special Features : Full bore for good flow characteristics. Suitabfe for inert industrial gases Suitable for water and other similar fluids. All PFTE seals. Hard chrome self-cleaning ball.
...moreUPS : Utility Pressure Switch
Food & beverage, pharmaceutical, cryogenics, chemical & petrochemical industries, conventional & nuclear power Plants, pumps, hydro-cleaning machines, presses, engine Compressors, turbines, diesel engines & refrigerating plants. Special Features : Field Adjustable Compact and Reliable Snap Action Microswitch
...moreUltrasonic Thickness Gauge
ultrasonic thickness gauge aluminum, red copper, brass, zinc, quartz glass, Thickness meter, Thickness gauge, Thickness tester, Coating thickness meter, Coating thickness gauge, Coating thickness tester.
...moreUDPS: Utility Differential Pressure Switch
Food & beverage, pharmaceutical, cryogenics, chemical & petrochemical industries, conventional & nuclear power Plants, pumps, hydro-cleaning machines, presses, engine Compressors, turbines, diesel engines & refrigerating plants. Special Features : Field Adjustable Compact and Reliable Snap Action Microswitch
Accuracy : : ±5% of F.S
...moreTWW : Socket Weld Thermowell
Model TWW thermowells are machined from solid bar stock. The thermowell diameter is designed to fit standard sizes of socket weld fittings. This design of thermowell will accept thermocouples (TC),resistance temperature detectors (RTD), as well as mechanical and digital thermometers To ensure correct positioning of the thermowell into the socket weld fitting OMICRON can supply a gap ring. This ring is inserted into the fitting allowing the correct spacing between the thermowell step and the base of the socket weld fitting prior to welding.Incorrect positioning could lead to undue stresses and possible fatigue of the weld. Special Features : Chemical, process, apparatus and plant engineering; petrochemical; on/offshore High chemical loads High process loads
Type : Socket Weld
...moreTWV : Vanstone Thermowell
Thermowells within the TWV series are machined from solid bar and mounted between mating flanges for process insertion. This design of thermowell will accept thermocouples (TC), resistance temperature detectors (RTD), as well as mechanical and digital thermometers. The dimensions of the Vanstone flange corresponds to the mating raised face diameter of the process flange.The Vanstone flange surface finish is usually machined with a phonographic spiral serration to match the mating process flange. During installation a gasket is inserted between the process flange and the Vanstone flange to maintain a pressure seal. A top flange is then placed over the Vanstone thermowell and bolted to the process flange using the correct bolting torque forces for the bolt size and material. The required lap flange is not standard and can be provided as an optional extra. Special Features : Chemical, process, apparatus and plant engineering; petrochemical; on/offshore High chemical loads High process loads
Type : Vanstone
...moreTWT : Sanitory Thermowell
TWT thermowells are manufactured from solid bar stock. They are installed into the process using a clamp connection. The smooth, polished surface of the wetted parts guarantee easy cleaning and prevents potential contamination of the process.This design of thermowell will accept thermocouples (TC), resistance temperature detectors (RTD), as well as mechanical and digital thermometers. Special Features : Food and beverage industry Biochemical and pharmaceutical industry Sterile process technology
Type : Sanitory
...moreTWS : Screwed Thermowell
Thermowells are used as accessories with temperature instruments and temperature sensors to protect its basic sensing element from corrosive and mechanical damages due to process parameters. Special Features : Fabricated From Bar Stock Standard For Manufacturing Followed- Ptc 19.3 Thermowell Available In Exotic Materials Such As Hastalloy-C, Tantalum, Monel, Titanium, Inconel 600 etc Thermowells Are Used As An Accessory With Temperature Instruments, Sensors, To Protect Its Basic Sensing Element From Corrosive And Mechanical Damages Due To Process Parameters
Type : Screwed
...moreTWP : Pipe Thermowell
Fabricated From Bar Stock . Standard For Manufacturing Followed- Ptc 19.3. Thermowell Available In Exotic Materials Such As Hastalloy-C, Tantalum, Monel, Titanium, Inconel 600 etc Thermowells Are Used As An Accessory With Temperature Instruments, Sensors, To Protect Its Basic Sensing Element From Corrosive And Mechanical Damages Due To Process Parameters
Type : Pipe Thermowell
...moreBe first to Rate