Welding Glove Box
The welding glove box system provides a high purity, low oxygen and moisture environment Includes two rectangular antechambers; One antechamber is heated (max 200 °C) Outer antechamber door manually controlled; Interior door automatically controlled The system purge is controlled with a flow meter; a separate purification system may be connected Dust removal units available for integration
...moreSuper Glove Boxes
Closed Loop Gas CirculationInert gas in a closed loop. The gas is circulated by the blower and purifier, H2O, O2 can be removed continuously. Auto PurgingThe replacement of the atmosphere inside the glove box can be achieved automatically by the purging valves. Automatic RegenerationH2O and O2 removal material can be regenerated. The regeneration process can be program controlled. Automatic Pressure ControlThe pressure in the glove box is controlled automatically by the Programmable Logic Controller (PLC). Working pressure can be set between +10mba and -10mba. If the pressure goes over+/- 12mbar, the system will be protected automatically. Eco ModeThe vacuum pump will be activated automatically when necessary, and will turn off after a period of idle time. Blower frequency will be switched to 25Hz when moisture and oxygen level reaches to less than 1 ppm Main Chamber DimensionsLength: 1220mm (48.0”)Depth: 750mm (29.5”)Height: 900m (35.4”)Material: Stainless steel type 304, thickness 3mm (1/8”)Sight Windows: Inclined, Safety Glass, thickness 8mm (1/3”)Gloves Ports: POM (Polyoxymethylene), 220mm (8.7”) DiameterGloves: 8B1532Dust Filter: HEPA 0.3μ, one gas inlet, one gas outletShelving: Stainless Steel, two fixed shelves (adjustable shelves available)Lighting: External fluorescent lamp, front mounted above sight glass.Feedthroughs: One power feedthrough, 3 blind-flanges Large AntechamberDiameter: 360mm (14.2”) or 400mm (15.7”), Length 600mm (23.6”)With Sliding traySpindle lock door, Vertical operation with lifting mechanismAutomatic operation via solenoid valve Small AntechamberDiameter 150 mm (5.9”) or 100mm (3.9”), Length 300mm(11.8”)Hinge doorManual operation via hand valve PurifierRemoval of H2O and O2 to Less than 1 ppm moisture and oxygenAbsorber Unit: 5kg Copper catalyst,5kg Molecular sieveCapacity to remove oxygen, 60L , moisture 2000g.Encapsulated Blower: 90m3/hRegeneration: PLC control all process including heating, introducing mix gas (working gas mixed with Hydrogen 5-10%), etc. System Control PLC and HMI: Siemens S7 Vacuum Pump 8m3/h Rotary vane pump with oil mist filter and gas ballast
...moreSuper Capacitor Glove Box
Movable oven with a maximum temperature of 200° C Exclusive docking system between oven and antechamber prevents any ambient air exposure Fully automated transfer between oven, cooling antechamber, glove box, and discharge chambers Cooled antechamber reduces energy use and speeds productivity One glove box used sequentially with multiple ovens saves capital cost Best for small batches of various samples
...morePotentiostat Galvanostat Gamry Instruments
Genral purpose, value-oriented for all applications. 12 V, 1 A EIS to 2 MHz
...moremultichannel potentiostat
Gamry’s multichannel potentiostat systems combine multiple research-grade instruments into a single, flexible system. This flexibility gives you the ability to run each channel separately, in groups, or all at once
...moreLow Cost Potentiostat
Entry-level low cost potentiostat Designed for undergraduate and graduate teaching lab EIS Capable
...moreAdvanced Glovebox
Closed Loop Gas CirculationInert gas in a closed loop. The gas is circulated by the blower and purifier, H2O, O2 can be removed continuously. Auto PurgingThe replacement of the atmosphere inside the glove box can be achieved automatically by the purging valves. Automatic RegenerationH2O and O2 removal material can be regenerated. The regeneration process can be program controlled. Automatic Pressure ControlThe pressure in the glove box is controlled automatically by the Programmable Logic Controller (PLC). Working pressure can be set between +10mba and -10mba. If the pressure goes over+/- 12mbar, the system will be protected automatically. Eco ModeThe vacuum pump will be activated automatically when necessary, and will turn off after a period of idle time. Blower frequency will be switched to 25Hz when moisture and oxygen level reaches to less than 1 ppm Main Chamber DimensionsModular length: 1220mm/1500mm/1800mm/2440mm ( 48.0”/59.1”/70.9”/ 96.0”)Modular depth: 750mm/1000mm/1200mm (29.5”/39.4”/47.2”)Modular height: 900m( 35.4”)Material: Stainless steel type 304, thickness 3mm (1/8”)Sight Windows: Inclined, Safety Glass, thickness 8mm (1/3”)Gloves Ports: POM (Polyoxymethylene), 220mm (8.7”) DiameterGloves: 8B1532Dust Filter: HEPA 0.3μ, one gas inlet, one gas outletShelving: Stainless Steel, two fixed shelves (adjustable shelves available)Lighting: External fluorescent lamp, front mounted above sight glass.Feedthroughs: One power feedthrough, 3 blind-flanges Large AntechamberDiameter: 360mm (14.2”) or 400mm (15.7”), Length 600mm (23.6”)With Sliding traySpindle lock door, Vertical operation with lifting mechanismAutomatic operation via solenoid valves Small AntechamberDiameter 150 mm (5.9”) or 100mm (3.9”), Length 300mm(11.8”)Hinged doorManual operation via hand valve Dual PurifierRemoval of H2O and O2 to Less than 1 ppm moisture and oxygenAbsorber Unit: 5kg Copper catalyst,5kg Molecular sieveCapacity to remove oxygen, 60L , moisture 2000g.Encapsulated Blower: 90m3/hRegeneration: PLC control all process including heating, introducing mix gas (working gas mixed with Hydrogen 5-10%), etc. System ControlPLC and HMI: Siemens S7 Vacuum Pump8m3/h Rotary vane pump with oil mist filter and gas ballast
...moreBe first to Rate
Rate ThisOpening Hours