Melt Pressure Transducers
Get Price Quote
MA1200 Series Economic melt Pressure Transducer designed for economic applications. The model MA1200 and MA1300 are introduced with automatic zero adjustment. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable externally if required, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.
Pressure Transducer
Get Price Quote
PRESSURE TRANSDUCER, 0 to DC 100mV 6 models : 2/5/10/20/50/100/400 bar. Zero pressure - 0 DCV, Full scale - 100 mV. Power supply : DC 9V to 30V. 4 wires : 2 wires for power, two wires for signal.
Best Deals from Pressure Sensors
Pressure Sensors
Get Price Quote
Barometric Pressure Sensor
Get Price Quote
BP20 Barometric Pressure Sensor A micro-machined absolute pressure sensor, the BP20 provides a high-level voltage output signal that is proportional to absolute pressure. The BP20 pressure sensor includes built-in temperature compensation, linearization, and an output amplifier. Its low cost and rugged ABS enclosure make the BP20 ideal for collecting absolute pressure data at remote sites. Specifications BP20 Barometric Pressure Sensor (#2046) Description Sensor type Micromachined integrated circuit absolute pressure sensor Applications Wind resource assessment Meteorological studies Environmental monitoring Sensor range 15 kPa to 115 kPa (4.43 inches to 34.0 inches Hg) Instrument compatibility All Symphonie Data Loggers Output signal Signal type Linear analog voltage Transfer function Absolute Pressure in kPa = (Voltage x 21.79) + 10.55 typical Accuracy +/- 1.5 kPa (15 mb) max. uncorrected offset (+/- 0.443 inches Hg) Calibration Calibration sheet included with each sensor specifies offset correction Turn on time 15 ms Power requirements Supply voltage 7 V to 35 V DC Supply current 15 mA max. (8 mA typical) Installation Mounting Mounts directly to tower or inside steel shelter box with hose clamps (included) Tools required 8mm (5/16 inch) nut driver or flat blade screwdriver Environmental Operating temperature range 10 C to 50 C at full accuracy At cold temperatures, offset increases by 3 kPa (30 mb) worst case at -30 C. Physical Connections Wire leads, 3 conductor shielded cable: Red: sensor power White: output signal Black: sensor ground Shield wire: to earth ground Cable length 1.5 m (5 feet) cable diameter 4.8 mm (3/16 inches) Weight 0.1 kg (0.2 pounds) Dimensions 57 mm (2.25 inches) diameter 112 mm (4.4 inches) length (including cable bushing) Materials Cable 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket Enclosure Weatherproof black ABS
Honeywell Pressure Transducer
Get Price Quote
Honeywell Pressure Transducer, copper contacts, Flexible Copper Connectors
Pressure Sensors
Get Price Quote
Pressure Sensors, sensor, Limit Switches, Proximity Sensors, VFD
Pressure Transducer
Get Price Quote
Pressure Transducer