wet riser system
We supply and provide services for high quality wet riser systems. While providing maintenance to the Risers, we conduct an initial physical inspection to check following components : Valves Pipework Seals Strap Padlock Earthing Cabinet locks Pressure test at inlet Pressure test at outlet Non return valves Drain down system
...moreWater Spray System
We offer our clients a range of water spray system that is manufactured by reputed vendors. These systems find application in various commercial and industrial establishments. We have several types available with us that include systems with G.M/SS type nozzles with stainless steel clamp for quick fixing or unfixing of nozzle. This arrangement helps in cleaning of the nozzles easily without any help of tools. Our water spray systems have sturdy looks and are durable enough to resist the pressure created by the water force.
...moreJet Nozzle
3,900 Per Piece
Hydrant Valves
We offer our clients 63mm Single outlet Landing Valve as per IS: 5290 Type A specifications. These ISI marked hydrant valves are available in 75mm NB inlet & 63mm female inst. outlet. These are manufactured by using Gunmetal of IS 318 LTB2 / SS304 / SS316 specifications. Its inlet can be provided in flanged type as per our client’s requirement. The outlet is generally female instantaneous and male inst. outlet is available on request. Our hydrant valves are available in size range of 38mm to 63mm.
...moreHose Reel
Hose reel is important equipment used for fire fighting purposes. We supply our comprehensive range of hose reels procured from reliable vendors. Our hose reels are UL approved and possess following features:
...moreflooding system
Our company supplies flooding systems that are based on Co2 (Carbon Dioxide) gas. Co2 is used in the system due to its high ratio of expansion that facilitates rapid discharge and allows three-dimensional penetration of the entire hazard area quickly. CO2 extinguishes a fire by reducing the oxygen content of the protected area below the point where it can support combustion. The extreme density of CO2 assists in permeating the protected hazard area effectively and suppresses the fire. Due to the rapid expansion of the 4-6 inches of CO2 snow to gas, the ambient temperature is reduced in the protected hazard area.This helps in the extinguishing process and retards re-ignition. CO2 is electrically non-conductive and it has no residual cleanup associated with its use as a fire-suppressing agent. The proper ventilation allows the gas to escape to atmosphere after the fire has been extinguished. This helps in the extinguishing process and retards re-ignition. CO2 is electrically non-conductive and it has no residual cleanup associated with its use as a fire-suppressing agent. The proper ventilation allows the gas to escape to atmosphere after the fire has been extinguished.
...moreFire Sprinkler System
Sprinkler is thermo-sensitive quarzoid liquid glassbulb burst actuated type and be standard products from an established firm of repute and standing and approved by an appropriate authority for fire fighting duty. It should be imported only. All sprinklers is brass castings polished / chrome OR white (polyester) unless stated otherwise and rated for 12.0 KG/CM2 WG and factory tested for 34.0 KG/CM2. Sprinklers is pendant OR side wall type as specified and shown on drawings. All sprinklers shall be provided with an adjustable OR Rosettes escutcheons finished same as the sprinkler head. Temp. classification of sprinklers in each space shall be as shown on the drawings. Sprinklers shall be selected for the coverage shown on the drawings and ordinarily be 15 MM. Wherever the specified sprinkler is not adequate. The tenderers may offer appropriate size required. Tenderers are free to suggest alternatively other suitable sprinklers with its justification.
...moreFire Hydrant Valve
We offer our clients 63mm Single outlet Landing Valve as per IS: 5290 Type A specifications. These ISI marked hydrant valves are available in 75mm NB inlet & 63mm female inst. outlet. These are manufactured by using Gunmetal of IS 318 LTB2 SS304 SS316 specifications. Its inlet can be provided in flanged type as per our client’s requirement. The outlet is generally female instantaneous and male inst. outlet is available on request. Our hydrant valves are available in size range of 38mm to 63mm.
...moreFire Hydrant System
We offer a range of FIRE HYDRANT SYSTEM and YARD HYDRANTS with all required accessories. Some of the feature of this systems are as follows - HYDRANT SYSTEM The Hydrant System comprises of AC motor driven pump sets with all required accessories including valves, instrumentation and controls etc. Complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent. Pipe work from the fire water pump set. The hydrant pipe work is remaining pressurized through the proposed jockey pump taking care of any leakages in the system pipe lines, valves and fittings. The hydrant system is kept charged by pressurized water at approx. 7 Kg. Cm. Sq. at all times. In the event of fire when any of the hydrant valves in the net work is opened,the resultant fall in pressure system is enabling starting the AC MOTOR driven fire water pumping set through pressure switches automatically. One diesel engine pump shall be standby pump serving hydrant system. Apart from the automatic starting of the pump sets,provision shall be kept for manual starting also. Shutting down of the pump sets shall be manual. YARD HYDRANTS Hydrants inside the building is furnished with required accessories such as hose pipes with instantaneous gun metal couplings and g.m branch pipes located in hose cabinets. The hose cabinets is wall / column mounting type, constructed out of 18 gauge mild steel sheets. The internal hydrants ( Landing valves) is single headed type taken out from 150/100 mm dia riser through suitable reducer. The outlets is gun metal and confirm to IS : 5290. HT Hose reels is firmly held against the wall by suitable heavy brackets and supports. The hose reel is swinging type ( 180 deg.) and the entire Dum reel etc. is as per IS : 3876. The rubber tubing is best quality ( Dunlop ) and the nozzle is 6 mm dia. Shut off type. The equipment shall be out of one of the approved makes. The hydrant main is laid in the form of ring main. The hydrant risers is terminated with air release valves at the highest points to release the trapped air in the pipe work.
...moreFire Hydrant
We offer a range of FIRE HYDRANT SYSTEM and YARD HYDRANTS with all required accessories. Some of the feature of this systems are as follows - Pipe work from the fire water pump set.
...moreFire Fighting Accessories
Fire Extinguisher
We offer our clients a wide range of fire extinguishers that comprise following types : A B C" Stored pressure type: Our ABC fire extinguisher is useful for fires of A, B and C types. Fire breaking out in these types involves cotton, wood, grease, flammable liquids, electrical wiring, live machinery and others. The blanketing effect of extinguishers helps in decomposing fire rapidly. Our equipment is available in following specifications:
Extinguisher Capacity : 1Kg, 2 Kg, 5 Kg, 10 Kg, & above with ISI Mark
...moreFire Detector
We specialize in supplying and providing services for our wide range of qualitative fire detectors. These are procured from certified and reputed manufacturers. Our range of fire detectors is available with following technical and general specifications : Light test feature makes testing easy with a flashlight beam 85 dB alarm Two 9-volt batteries included 5 year limited warranty
...moreFire Alarm System
We offer our clients our qualitative range of fire alarm systems that is manufactured by certified companies. These fire alarm systems work on 230V supply and have provision for battery backup. The equipment provides relay output for interfacing with security panel, auto-dialer, audio alarm via siren or buzzer and have zone-wise visual indications for open, short, test or bypass conditions.
...moreCo2 Flooding System
Our company supplies flooding systems that are based on Co2 (Carbon Dioxide) gas. Co2 is used in the system due to its high ratio of expansion that facilitates rapid discharge and allows three-dimensional penetration of the entire hazard area quickly. CO2 extinguishes a fire by reducing the oxygen content of the protected area below the point where it can support combustion. The extreme density of CO2 assists in permeating the protected hazard area effectively and suppresses the fire. Due to the rapid expansion of the 4-6 inches of CO2 snow to gas, the ambient temperature is reduced in the protected hazard area. This helps in the extinguishing process and retards re-ignition. CO2 is electrically non-conductive and it has no residual cleanup associated with its use as a fire-suppressing agent. The proper ventilation allows the gas to escape to atmosphere after the fire has been extinguished.
...moreCctv Systems
In our wide range of fire fighting equipment and accessories, we have CCTV systems that play vital role in identifying the source of firebreak and preventing it to spread further by alerting fire fighting personnel. Our CCTV systems are available in following specifications: Number of pixels PAL: 512(H)*582(V) System of signal NTSC/PAL Lens 16mm Horizontal resolution 420TVL Minimum illumination 0Lux Back light compensation auto Electronic shutter 1/50(1/60) ~1/100,000sec White balance auto S/N ratio 48dB Gamma correction 0.45 Operation temperature -20~50 Sync. System internal Video output 1.0v p-p /75Ω Power supply DC12V, 8000mA Dimensions (mm) 60(w)*55(h)*130(d)
...moreBulb Sprinkler
Sprinkler is thermo-sensitive quarzoid liquid glassbulb burst actuated type and be standard products from an established firm of repute and standing and approved by an appropriate authority for fire fighting duty. It should be imported only. All sprinklers is brass castings polished / chrome OR white (polyester) unless stated otherwise and rated for 12.0 KG/CM2 WG and factory tested for 34.0 KG/CM2. Sprinklers is pendant OR side wall type as specified and shown on drawings. All sprinklers shall be provided with an adjustable OR Rosettes escutcheons finished same as the sprinkler head. Temp. classification of sprinklers in each space shall be as shown on the drawings. Sprinklers shall be selected for the coverage shown on the drawings and ordinarily be 15 MM. Wherever the specified sprinkler is not adequate. The tenderers may offer appropriate size required. Tenderers are free to suggest alternatively other suitable sprinklers with its justification.
...morealarm valve
CCTV System
Fire Fighting Systems
Smoke Detectors
SPRINKLER SYSTEM
sprinkles head
cctv system.
Be first to Rate
Rate ThisOpening Hours