APFC Panel
1,650 Per Piece
Automatic Power Factor Control Panel
Get Price Quote
neon has full-fledged expertise in solving problems related to electrical energy management. neon product are dedicated to the betterment of utilization of electrical energy. We have vast experience in the installation and commissioning of automatic power factor control system based on your controllers and allied products. We offer our experience based on this experience to you by way of providing problems of energy management related to power factor improvement..What is Power Factor(P.F.)?Power Factor (P.F.)is the ratio of active power to apparent power-i.e P.F.=KW/KVA Power Factor is the – so – to say efficiency of utilization of electrical power. It is obvious that KW =KVA X P.F. Thus for a given voltage and active power (KW), the current drawn is inversely proportional to the power factor.
Best Deals from Switchgear Panels
APFC Panel
Get Price Quote
The basic purpose of Contactor Switched Automatic Harmonic Filter Panel is centralized Reactive Power Compensation with Harmonic Mitigation. Automatic control is provided using Automatic Power Factor Control relays. The switching of individual steps is through contactors or thyristors. With thyristor switching it is possible to have panels at higher voltages (upto 690 V), and with large size of single step (108-kVAR). Based on the load variation pattern, the minimum and maximum size of steps can be determined to maintain optimum power factor. These will help partly mitigate the harmonics from the system.
Relay Panel
50,000 Per Set
1 Set (MOQ)
Solid State Relays Panel
Get Price Quote
LV SWITCHGEAR and CONTROL PANEL
Get Price Quote
TYPE AC & DC Distribution Boards MCC & PCC LDB & PDB DG Protection, Synchronising Panels, AMF Panel Metering Panel Custom built Distribution, Instrumentation & Protection Panels FEATURES Single front, Double front, Fixed type, Semi draw-out type, Fully draw-out type, Fully isolated Vertical & Horizontal busbar chamber Fully isolated cable chamber Manufactured out of CRCA sheets Floor mounting, free standing, Vermin & dust proof Powder coated with 7 tank pretreatment Degree of protection upto IP55,Short circuit withstand strength up-to 50KA PLC based AUTOMATION Panels with MMI Mass-Tech offers PLC based total solution to your Automation needs.The scope covers system engineering, selection of optimum hardware, programming, designing MMI screens and plant specific database, reports generation. In-house trial & site commissioning is also supported. Mass-Tech also offers PLC based systems for DG control and synchronisation, Conveyor systems such as Ash handling system, Building automation including control of AHU, lighting, water treatment units, parking etc. RATING 440V AC, 220V DC upto 5000A, Customize as per requirement
APFC Panels
Get Price Quote
1 Piece(s) (MOQ)
Apfc panel normal, de tuned & tuned in an industrial plant containing power factor correction capacitors, harmonic currents and voltages can be magnified considerably due to the interaction of the capacitors with the service transformer. This is referred to as harmonic resonance or parallel resonance. For a typical plant containing power factor correction capacitors, the resonant frequency (frequency at which amplification occurs) normally falls in the vicinity of the 5th to the 13th harmonic. Because nonlinear loads typically inject currents at the 5th, 7th, 11th and 13th harmonics, a resonant or near-resonant condition will often result if drives and capacitors are installed on the same system, producing the symptoms and problems with blown fuses, damaged capacitors or failures in other portions of the electrical distribution system. it is a common misconception that the problem of applying capacitors in harmonic environments is limited to problems caused for the capacitor itself that the capacitor’s lower impedance at higher frequencies causes a current overload into the capacitor and, therefore, must be removed. However, the capacitorharmonics problem must be viewed from a power system standpoint. Capacitors and transformers can create dangerous resonance conditions when capacitor banks are installed at the service entrance. Under these conditions, harmonics produced by nonlinear devices can be amplified many times. Problematic amplification of harmonics becomes more likely as more kvar is added to a system which contains a significant amount of nonlinear load. Our normal ,de-tuned & tuned panels are well positioned in market all over india in government ,public & private sectors. We manufacture the same with utmost care so that, simultaneously harmonics and power factor go hand in hand. Now in india only tamilnadu state govt. Issue harmonics penalty , other states also apply the harmonics penalty in short time.
Relay Panel
Get Price Quote
Relay Panel, Lt Panels, amf control engine panel, Fire Fighting Panels
Mcc Panel
Get Price Quote
Sigma Servo 5 Drive, crane panel, Active Front End D 1000 Inverter AC Drives
electric sub panel
Get Price Quote
electric sub panel, home electrical panel, industrial electrical panels
Mcc Control Panels
Get Price Quote
Mcc Control Panels, Pcc Control Panels, feeder pillars
APFC Panel
Get Price Quote
AMC, Control Panel Board
Apfc Panels
Get Price Quote
MCC Panels
Get Price Quote
MCC Panels, Diesel Generators, Lt Panels, Ht Panels, Electrical Panels
Motor Control Center Panel
Get Price Quote
Auto Mains Failure Panel, heater panel
Apfc Panels
Get Price Quote
Relay Control Panel
Get Price Quote
Power Harmonic Meter, Testing Equipment Electronic, Transformer
Automatic Power Factor Correction Panel
Get Price Quote
Power Factor Correction Capacitor, Harmonic Filters