Wire Conventional Smoke Detectors
System Sensor 100 Series low-profile detectors use stateof- the-art sensing chambers to meet all applicable UL performance criteria. The backs of the smoke detectors are sealed against back pressure, air flow, and dirt. A fine mesh screen also protects the chamber against the entry of insects. These detectors are intended for open area protection and for use with UL-listed control panels. of insects. These detectors are intended for open area protection and for use with UL-listed control panels. features • Smart-Check™ self-diagnostic maintenance feature tosatisfy NFPA 72 sensitivity testing requirements. • Larger plug-in terminal block with captured SEMS screwsdecreases wiring and installation time. • Removable insect screen protects sensor from insectsand airborne dust. • Includes auxiliary Form-C relay (“R” suffix).• Built-in test switch.• Visual alarm, power, and maintenance indicator. • Refined insect screen for a tight seal; simplified,removable for cleaning. • Thermal models available. • Ceiling white color.• 12/24 VDC operation. • Built-in sounder and temporal tone. • Three-year warranty.System Sensor 100 Series low-profile, direct-wire detectorspack superb performance and reliability into a smallpackage. Their sleek, 1.7"" (43 mm) profile is the lowest inthe industry, and the advanced circuitry provides superiorfalse-alarm immunity, while reducing maintenance.Other key features include: • Low current draw.• Stable performance in high air velocities. • Built-in tamper-resistant base design. specification • Operating voltage: 12 or 24 VDC (nominal). • Contact rating: 1 Form-C, 1.0 A @ 30 VDC. • Standby current: 50 μA maximum average. • Alarm current: 2-wire models: 100 mA maximum limited by panel. 4-wire models: 12 VDC = 35 mA maximum; 24 VDC = 45 mA maximum (2112/24AITR: 60 mA maximum and 70 mA maximum respectively). • Temperature range: 32°F to 120°F (0°C to 50°C). For 2100TD, 2112/24TR models: 32°F to 100°F (0°C to 39°C). • Dimensions: 5.5"" (140 mm) diameter. Height 1.7"" (43 mm) including adapter bracket. • Shipping weight (approximate): 5.3 oz. (150 g). • Humidity range: 10% - 93% RH, noncondensing. • Smoke detector spacing: On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (900 sq.ft.) may be used as a guideline. Other spacing may be used depending on ceiling height, high air movements, and other conditions or response requirements. Refer to NFPA 72 and local authority having jurisdiction. • Air velocity: 0 to 3,000 ft./min. (914.4 m/min.) maximum.
...moreWater Leak Detection System
A TraceTek locating sysem detects the leak at its source, signals the alarm, and displays the exact distance to the leak. By referring to a map of the system layout (supplied as part of the TraceTek system), you can quickly locate the leak source. features HVAC equipment Telephone switch gear Mehchanical or electrical equipment areas Building service columns Computer rooms Telephone equipment rooms Archives with sprinkler systems Restrooms and service areas Basement storage
...moreElectronic Sounder Fire Alarm
The NXS14 is a combined wall mounting sounder and xenon strobe contained within a single enclosure. It combines the technologies from both the NX and NS series to provide audible and visual indication. The acoustic efficiency and sound distribution generates a maximum of 103dBA (@ 1m, 24Vdc) through a wide angle giving good audibility in all directions. Thee combined units are especially suitable for applications in buildings where members of the general public congregate. The internal solid state electronics provide the user with a choice of either continuous or sweeping tones at a variety of frequencies and volume levels. 14 preconfigured sounder patterns/tones are available for selection. The NXS sounders can be integrated onto systems using other sounders or strobes from either the Morley-IAS portfolio or any other compatible systems. FEATURES • Combined sounder & strobe • 88 - 103dB(A) adjustable output • Internal volume control • Wall mounting • Large strobe lens • Rugged construction • IP44, IP55 or IP66 rated • Easy cable entry & exit • Designed to meet EN54: pt 3 • CE marked
...moretelephone handset
The VoCALL Emergency Voice Communications System (EVCS) is designed to fully comply with BS5839-Part 9:2003 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. An EVCS is a fixed, secure, bi-directional, full duplex voice communication system to assist fire fighters in an emergency in high rise buildings or large sites where Radio communication may not work, and covers the operation of both fire telephones and disabled refuge systems. Where both systems are fitted to a building Part 9 specifies these should form a single system FEATURES Compact Design High Volume Ringer Status LED 20mm Cable Glands Telecoil for Hearing Impaired Users Magnetic Push Catch Fully Monitored Stainless Steel Option
...moretelephone jack
The VoCALL Emergency Voice Communications System (EVCS) is designed to fully comply with BS5839-Part 9:2003 Part 9 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. An EVCS is a fixed, secure, bi-directional, full duplex voice communication system to assist fire fighters in an emergency in high rise buildings or large sites where Radio communication may not work, and covers the operation of both fire telephones and disabled refuge systems. Where both systems are fitted to a building pt9 specifies these should form a single system. The VCRHS Roaming Phone is used along with the VCSJP Style Jack Plate in the EVCS system, multiple Jack plates can be connected in parallel on a run such as a stair core, calls are initiated when the Roaming phone is plugged into the jack point. FEATURES Flexible Roaming Phone High Quality Telephone Jack Full Duplex Conversion Flexible 30cm Roaming Cable Telecoil hearing impaired users Low Noise, High Quality Telephone Jack Full Monitored Stainless Steel Jack
...moresensor system
System Sensor’s SSM and SSV series bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications Reliable Performance. The SSM and SSV series provide loud resonant tones. The SSM series operate on 24VDC and are motor driven, while the SSV series operate on 120VAC utilizing a vibrating mechanism. Simplified Installation. For indoor use, the SSM and SSV series mount to a standard 4 inch square electrical box. For outdoor applications, weatherproof back box, model number WBB, is used. The SSM and SSV series come pre-wired, to reduce installation time. The SSM series incorporate a polarized electrical design for use with supervision circuitry. FEATURES Approved for indoor and outdoor use Low current draw High dB output Three sizes available 6"", 8"", 10"" AC and DC models DC models are polarized for use with supervision circuitry Mount directly to standard 4"" square electrical box SPECIFICATION Operating Temperature Range -31°F to 140°F Operating Voltage SSM series 24VDC SSV series 120VAC Termination Provided with 2 sets of leads for in/out writing Service Use Fire Alarm General Signaling Burglar Alarm Warranty 3 years
...moreRACK Secure Power Supply
ATEÏS PS-RACK Secure Power Supply, to all or a part of the Security Sound Systems (S.S.S.) used to generate and broadcast the audible general alarm signal throughout one or more alarm zones. These systems fulfil their design function both in normal operation and under emergency conditions in line with the safety regulations intended to prevent fire and panic hazards in facilities that are open to the public. features Battery recharging, - Distributing battery current to the point of use in the event of an alarm. - Testing the battery grid. - Indicating operating states. - Providing a guaranteed 30-minute endurance under alarm conditions, so long as the battery is sized adequately.
...morePRESSURE SWITCH SYSTEM SENSOR
Robust Construction. The EPSEXP series consists of a rugged, NEMA 4 rated cast aluminum housing. Designed for both indoor and outdoor use, the EPSEXP series operates across a wide temperature range, from –40°F to 160°F. Reliable Performance. The EPSEXP series cover is secured with a tamper resistant screw to prevent unauthorized tampering. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block to assure reliable performance. Simplifi ed Operation. Like all System Sensor pressure switches, the EPSEXP series is designed for easy installation. The EPSEXP series includes a pressure adjustment wheel that requires no special tools. This feature permits fi eld-adjusting of the activation switch FEATURES Designed and approved to operate in hazardous locations Rugged NEMA 4 rated cast aluminum housing Field-adjustable pressure sensitivity 1/2" NPT male brass fitting Synchronized activation circuit Two conduit entrances Tamper resistant screw SPDT (Form C) synchronized switches enclosed in a durable terminal block SPECIFICATION Hazardous Locations Classifi cationsClass I, Div 1, Groups B, C, D Class II, Div 1, Groups E, F, G Class III, Div 1 Maximum System Pressure 250 psi (max.) Pressure Connection ½” NPT male brass fi tting Contact RatingsTwo sets of SPDT (Form C) 10.0 A,1/2 hp @ 125/250 VAC 2.5 A @ 6/12/24 VDC Overall Dimensions Installed 4.9Ë W × 9.5Ë H Conduit EntrancesTwo openings for ½”conduit Operating Temperature Range–40°F to 160°F (–40°C to 71°C) Enclosure RatingNEMA 4 – suitable for indoor/outdoor use Shipping Weight 6.2 lbs. Service UseAutomatic Sprinkler: NFPA-13 National Fire Alarm Code: NFPA-72 Warranty 3 years
...morePublic Address System
The CCTV Mini Balun allows a single CCTV video signal to be transmitted via cost-effective unshielded twisted pair (UTP) cable. Used in pairs, the CCTV Balun eliminates costly and bulky coaxial cable, allowing CCTV security and surveillance equipment to be connected using standard structured cabling techniques for neater and more streamlined cabling. The flexible mini coax cable lead allows the product to fit neatly inside CCTV camera back boxes and dome camera enclosures. The CCTV Balun also works in conjunction with other MuxLab CCTV baluns such as the 500000, 500009 and 500015 for a complete cabling solution. FEATURES Benefits Fits inside CCTV dome cameras and back boxesCompatible with other MuxLab CCTV balunsUp to 2200 feet (670m) via Cat5e/6 UTP*Cable strain relief
...moreMagellan Counter Intercom System
MAGELLAN is a digital counter intercom which enables a high quality full duplex connection using digital processing of the audio signal. The MAGELLAN intercom consists of the following components: ï® Client Side: a (MC) microphone, one or two loudspeakers (HPU) and a broadcast antenna for hearing impaired people. ï® Agent Side: a microphone equipped with control keys and pilot lamps (MAS) and one or two loudspeakers (HPU). ï® A central unit (UC) with integrated digital speech processing by DSP (Digital Signal Processor). FEATURES Full Duplex Bandwidth: 8 KHz Fully digital (DSP) Antilarsen via echo cancellation (without filtering) Nominal power: 4 W/8 Ohms Programmable output level Automatic gain control Limiter Automatic stand-by-mode Anti-vandal microphones and speakers SPECIFICATION Conditions for use: temperature of -10 °C to + °C, relative humidity: 100%, water-tightness: IP2
...moreMagellan Compact Counter Intercom
The MAGELLAN COMPACT intercom consists of the following components: Client Side: A (MC) microphone, one loudspeaker(HPU) and a broadcast induction antenna toserve hearing impaired people. Agent Side: A compact unit (PMUC)housing the agent microphoneequipped with control keys and pilotlamps, one loudspeaker and the electronics with integrated digitalspeech processing by DSP (DigitalSignal Processor). FEATURES Feedback Killer for open counterconfiguration or Echo Cancellation for closeCounter configuration +6dB amplification threshold button onagent’s unit Standby time and threshold on agent’s unit High pass Filter used as a windshield filteron client side Inductive Loop antenna amplifier 0 dB auxiliary output for remote calling(when the ON Key is pushed for at least 2seconds, the ON Led starts blinking andagent can call through auxiliary output tillthe ON-key is released. ) 1 remote output switching contact (definition within software) Buzzer contact closure to page agent sideby means of a remote contact closure. SPECIFICATION Power supply: 230 VAC/50 Hz/0.2 A. Max input level: -18 dBu. Distortion:58 dB. Conditions for use: temperature of -10 °C to+40 °C, relative humidity: 100%, water-tightness: IP2.
...moreloud speaker system
The ATEÏS JD20 and JD20/T is a mini Foreground Music Loud Speaker System, with extended uniform frequency response. Small in size and weather resistant, it is available in both black and white options for improved aesthetics. The JD speakers comprise Polypropylene Cone, Rubber Surround and Neodymium Tweeter to provide Low and Mid-High frequency response with high quality sound to match most of the foreground applications.
...moreLoop Powered Strobe
The MI-STR is a low profile analogue addressable loop powered strobe designed for use with Morley-IAS protocol fire alarm control panels. This product forms part of a co-ordinated range of high quality, high performance products featuring unique styling and high efficiency. The loop-powered strobes have a very low current consumption (< 4.1mA when active). This low current allows a greater number of strobes to be powered from a single loop. The MI-STR loop powered strobe is manufactured as an analogue-addressable device with accompanying base. With the advent of the Disability Discrimination Act, the loop-powered strobe makes a useful addition to the Morley-IAS range of devices in facilitating compliance with certain aspects of the Act. The loop-powered strobe has been designed to simplify installation and includes terminals for both incoming and outgoing cables and an earth termination for cable screens. Mounting hardware and installation instructions are provided with each device. FEATURES • Loop powered • Low-profile design • Analogue addressable communication • Low current consumption • Wide viewing angle • IP54 rated model • Stable communication technique with noise immunity • Morley-IAS Protocol SPECIFICATION mechanical Dimensions: 53mm x 93mm (H x Dia.) Weight: 100gr. Operating temperature: -10 to +60ºC IP rating: IP54 Material: Red ABS and polycarbonate Connector termination: 0.5 to 2.5mm2 cable electrical Operating voltage: 15 to 30Vdc Current consumption: Supply current (strobe off with comms) 650μA Active current < 4.1mA Flash rate: 0.5Hz Intensity: 0.3 candela
...moreAudio Communication Systems
Introducing a new level of inter-company security and communication systems ATEÏS brings a Revolutionary IP-based intercom systems that has NO centralized equipment or matrix, the Network itself is your switching matrix! These attractive systems offer a sleek, contemporary appearance with recessed wall mounted and flush mounted ‘slave’ and ‘Master’ call stations. They are the easiest, most affordable way to build security, convenience and safety into your environment. With a variety of style and color options, TerraCom is the system to complement thedécor of any venue. FEATURES Ethernet interface including POE (Power On Ethernet) 24 VDC power supply (if no POE available) Monitored high quality gooseneck microphone Automatic gain control on microphone input Monitored built in loudspeaker SPEEX/MP3 audio encoding/decoding Memory space for pre-recorded messages RJ9 plug for optional headset LED Power (green) 2 monitored input contacts on Euroblockscrew terminals 2 output contacts NO/NC
...moreFire Weather Resistant Systems
The WR4072 manual call points have been developed to provide a manual alarm interface to conventional fire alarm systems. They have been engineered to provide a high degree of protection against the elements. High quality switching components and materials combine to provide excellent reliability and safety. The call point is fitted with a 470 ohm internal resistor to facilitate usage on monitored systems. The call point is IP67 rated when correctly mounted and sealed within its surface mounting back box. The back box features two threaded cable entry holes to simplify installation. One of which is already fitted with a removable stopper. Functional testing of the call points is easily achieved through the use of a specialist test key (provided) which is simply pushed into the bottom of the unit to activate the switch. FEATURES • Safe and reliable • LPCB certified to BS5839 :part 2 : 1983 • IP67 rated • Terminals for up to 2.5mm2 conductors • Complementary range of accessories • Intrinsically safe option SPECIFICATION mechanical Material Call point - Polycarbonate ABS plastic/polyphenylene oxide (NORYL SE100) Back box - 15% glass reinforced nylon 6 Flammability UL94-HBelectrical Connection drawing for WR4072/GS-470
...moreFire Lite Modules
The Fire·Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire·Lite’s addressable fire alarm control panels (FACPs). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED”appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semiflush mounted. Semi-flush mount to a standard singlegang, double-gang, or 4"" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guidelines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes.
...morefire telephone
The ECC-FFT is a firefighter telephone system that provides secure and reliable communications for firefighters. This standalone system is capable of providing annunciation and control for local and remote telephone handsets. It includes a built in display and keypad that provide an indication of phone activation as well as corresponding trouble conditions. For added flexibility, 24 remote telephone connections are offered that can be monitored individually or as a group of multi-phone jacks. Adhering to Firelite’s benchmark for effortless setup and configuration, the auto-program feature automatically recognizes all existing fire fighter phone jacks on the system and immediately configures the system for full operation and supervision. The ECC-FFT allows for up to ten users to plug in to a remote telephone jack (FPJ-F) and communicate simultaneously within a building. An onboard SLC circuit (capable of being wired in Class B (Style 4) or Class A (Style 6)) allows for continuous monitoring of the telephone jacks connected to the system. It is housed in a sturdy, lockable cabinet that includes multiple knockout locations for field wiring. features • Provides supervision control and annunciation of up to 24 remote telephone jacks. • Built-in Auto-program feature. • Simplistic and straightforward user interface. • Telephone circuit supervised with 4.7KïÂ�—, End of line resistor when wired in Style Y, Class B operation. • Full System status LED display. • Onboard SLC circuit can be wired for class A (Style 6 or Style 7) or class B (Style 4) configuration. • Full system status LED display. • Supports Multi-Phone Jack Audio Circuit supervision. • Onboard Form-C system trouble relay. • Allows simultaneous operation of up to 10 firefighter remote handsets (FHS-F) when connected to the ECC-FFT. • Fire Fighter Phone Jack (FPJ-F) provides a plug-in location for the FHS-F. • Fire Fighter Handset Cabinet (FHSC-RF/SF) is used to store five Fire Fighter Handsets (FHS-F). specification PRIMARY POWER REQUIREMENTS: • Voltage 24VDC (nominal) power limited, filtered, non-resettable. • Voltage Range for operation: 17-29 VDC. • Current Requirements: – Standby: 120mA. – Active: 230Ma . ELECTRICAL RATINGS • SLC circuit: – Voltage output: 32VDC. – Current rating: 150mA. • Audio Circuit: – Voltage output: 17VDC.
...moreFire Lite Annunciator
The LCD-80F is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the Fire•Lite MS- 9200 Series and MS-9600 Series Fire Alarm Control Panels (FACPs). The LCD-80F displays complete system point status information and includes control switches for remote control of critical system functions. features • 80-character Liquid Crystal Display. • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key.• System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. • No programming necessary — LCD-80F connects to the terminal port (TB7) on the FACP.• Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels. • Time-and-date display field. • Aesthetically pleasing design. • May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). • Up to 32 LCD-80F annunciators per FACP. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. • Local piezo sounder with alarm and trouble resound. • Semi-flush mounts to 2.188"" (5.556 cm) minimum deep, three-gang electrical box (Fire•Lite P/N 10103) or threegangable electrical switchbox. • Surface-mounts to Fire•Lite SBB-3 surface backbox. specification The LCD-80F annunciator provides the FACP with pointannunciation with full display text on an 80-character LCD display. The LCD-80F also provides an array of LEDs to indicate system status, and includes control switches for remote control of critical system functions. The LCD-80F provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the LCD-80F use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communications (two in and two return); and two for the 24 VDC regulated power. Dip switches control local functions such as: piezo disable, control switches/key-switch disable, transmit/receive mode.
...moreFire Duct Detector
The Fire•Lite InnovairFlex D355PL intelligent non-relay photo- electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, tem- peratures of -4 degrees F to 158 degrees F, and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sen- sor cover. The Fire•Lite InnovairFlex housing provides a 3/4- inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module. The Fire•Lite InnovairFlex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. features • Photoelectric, integrated low-flow technology • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s) • Versatile mounting options: square or rectangular configura- tion • Broad ranges for operating temperature (-4F to 158F) and humidity (0% to 95% non-condensing) • Patented sampling tube installs from front or back of the detector with no tools required • Cover tamper signal • Increased wiring space with a newly added 3/4” conduit knockout • Available space within housing to accommodate mounting of a relay module • Easily accessible code wheels on sensor head (sold sepa- rately) • Clear cover for convenient visual inspection • Remote testing capability • Requires com line power only • Accommodates the installation of an addressable relay mod- ule, sold separately, (CRF-300) for applications requiring a Form-C relay.
...morefire detection systems
The DR/W range of door retainers offer new standards of performance and aesthetics for fire detection systems requiring electromagnetic fire door retainer’s. Each door retainer is fitted with a spring loaded release pin mounted centrally within the electromagnet. On power off, the release pin then ensures that the fire door is pushed away from the electromagntA replaceable fuse is fitted to each magnet, together with a spark quenching diode and protection against reverse polarity. All the electromagnets have been tested and comply with the latest requirements of EN61000-3-2 and EN5008-1. The new low profile housing results in an attractive and robust design. The detailed use of rubber seals coupled with moulding design has resulted in a high degree of protection against moisture ingress. Cable installation is via M20 knockouts in the base of the unit into terminal blocks, using cable up to 2.5mm2. FEATURES • Low profile design • IP51 • 112 N holding force • Easy cable entry & exit • AC or DC options SPECIFICATION electrical Operating voltage DR/W/DC 24Vdc ±10% DR/W/AC 240Vac ±10% Current consumption DR/W/DC 50mA DR/W/AC 12mA
...moreFire alarm Xenon Strobes system
The NX series Xenon strobe units are available in two power ratings, 2 watt or 5 watt. The NX2 is a 2 watt xenon with a red base and red lens. The NX5 is 5 watts with a red base and red lens. The strobes are designed with a distinctive shape enabling a large lens to be incorporated. The internal electronic design is engineered to maximise light output. The strobes are low profile and allow simple installation through separate terminals for both input and output wiring. The NX strobes can be integrated onto systems using other sounders and strobes from either the Morley-IAS portfolio or any other compatible systems. features • Xenon strobe unit • Stand alone operation • Large strobe lens • IP44, IP55 or IP66 rated • Easy cable entry & exit • Separate terminals for in/out wiring • CE marked specification mechanical Material ABS body Flammability UL94-HB Colour Red base and red lens Dimensions (H xWxD) 124 x 92 x 60 mm (using NBL base) 124 x 92 x 72 mm (using NBD or NBS base) Operating temperature -25°C to + 70°C Maximum humidity 93% @ 55°C (NBD base)
...moreFire Alarm Systems
The patented communication protocol has a unique design of Variable Time Communication “VTC”. This new technology allows the data packets to transmit on the Fire Detection Loop for along distances and does not gets a ected with the Cable Characteristics. This technology shall help a healthy communication at the worst site installation conditions, or even during the severe re conditions. The Soft Addressing shall allow automatic addressing from the Fire Alarm Control Panel, making the commissioning of the system an easy and fast task. features Complies to EN54 part 3 + A1 Connected and Powered from the loop Soft Addressing Safe Addressing Inbuilt Short Circuit Isolator High dB output up to 100dB @1m Compact in size Lockable base
...moreFire Alarm Control Panel
The Fire•Lite MS-25(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. With an extensive list of powerful features, the MS-25 fits into applications previously served only by conventional panels. This compact, intelligent addressable control panel supports up to 25 Honeywell Fire Systems addressable devices of any type of detectors and modules. With code wheel addressable detectors/modules and JumpStart® feature the MS-25 can be Life Safety operational without a single programming tool. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Fire-Lite. The MS-25's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The power supply and all electronics are contained on a single circuit board and housed in a metal cabinet. Custom programming can be performed through FACP built-in browser (no programming software required) with a PC. NOTE: Unless otherwise specified, the term MS-25 is used in this data sheet to refer to the MS-25 and the MS-25E. For details on the Canadian version, see DN-60641. features • Two independently programmable output circuits. Circuits can be configured for the following outputs: – Style Y (Class B). – Door Holder Service (cannot be used for notification appliances). – Aux Power Source (cannot be used for notification appliances). • Silence Inhibit and Auto-silence timer options. • Continuous or Temporal code. • Selectable strobe synchronization per NAC. • Up to 2.0 A total output power, 1.0 A for auxiliary power and door holder. Each circuit can source up to the total system current 2.0 A. specification • ETL listed to ANSI/UL 864 9th Edition Standard • Listed to UL Standard 864, Ninth edition. • JumpStart® auto-learn feature reduces installation time and makes programming easy. • Built-in digital communicator. • Two programmable Style Y (Class B) notification appliance circuits (NACs). • Selectable strobe synchronization for System Sensor®, Gentex®, Wheelock® or AMSECO devices. • Two programmable Form-C relays and one Form-C trouble relay. • Automatic detector sensitivity testing (NFPA 72 compliant). • Point status eliminates calibrated smoke test requirements for NFPA 72. • Drift compensation. • Alarm verification per zone of detectors. • Walk-test. • Honeywell Fire Systems detectors and modules are codewheel addressed for faster installation time. • Maintenance alert region. • Uses standard wire (unshielded or twisted pair). • Central Station reporting up to five zones. • On Board Annunciator.
...moreFire Alarm Bell
The innovative and robust KFB6 motor driven fire alarm bell offers excellent sonorous tone, high sound output and proven reliability with some models only drawing 11mA. The 150mm (6 inch) version features the revolutionary aluminium gong offering enhanced acoustics and greater sound output. Improved design means easier and quicker installation. The low profile design meets the aesthetic requirements of architects and specifiers. features • Low current consumption • Quickly and easily installed • Excellent sonorous tone • 95dBA at 1 metre • Slim profile • Fully suppressed and polarised • Multi-fixing base plate SPECIFICATION Part Number KFB6 Rated Voltage + 20% 24 Vdc Rated Current + 20% 11 mA Sound Output @24V 95dBA@1m Temperature Range -10 to +50 Co Humidity Range 45 - 85% Weight 410g Gong Colour Red
...moreBe first to Rate
Rate ThisOpening Hours