RETRO FITTING SWITCHGEAR
RETROFITTING OF OLD EXISTING SWITCHGEAR WITH NEW BREAKERSWith Today's latest innovations, which are changing everyday, the power requirements of the industry are increasing day by day. Thus, equipment is subjected to loads beyond their rated value. The equipment is also required to perform reliably, meet the necessary standards, sustain increasing fault levels and be compatible with the latest communication systems. In many cases, it is economically more cost effective to undergo retrofit solutions rather than replacing the existing breakers. The key value proposition of Retrofit solutions is the optimization of performance and investment. Basically, it means replacement of the equipment having the same or more advanced features to give advanced functionality and reduced maintenance. Overall it increases the system reliability, personnel safety and long term availability of spares. Thus, reducing the investment and down time.
...moreIndoor VCB Panel
Panels are designed in accordance with ABB’s guidelines and as per IEC IS Standards. Compact and Robust Cassette mounted CB of ABB make with draw out feature with cubicle front door closed Complies Complies to latest standards standards of IEC 62271‐200 Modular structure with metal clad design with inter panel metal segregation Lockable Automatic Safety Shutters for Breaker Compartment Mechanical indication of test and service positions Long mechanical life with sturdy and proven operating mechanism Electrical anti‐pumping
...moreindoor panels
Features :Indoor Panels / Outdoor Kiosks Panels are designed in accordance with ABB's guidelines and as per IEC / IS Standards. Compact and Robust Cassette mounted CB of ABB make with draw out feature with cubicle front door closed Lockable Automatic Safety Shutters for Breaker Compartment Mechanical indication of test and service positions Long mechanical life with sturdy and proven operating mechanism Electrical anti-pumping Fully Compartmentalized construction with IP4X degree of protection externally and IP2X between compartments for Indoor Type Bus Riser is provided in bus coupler panel itself for panels rated upto 12KV 2000A, leading to floor space saving. Emphasis on Operator's safety by: Foolproof mechanical interlock to prevent rack-in and rack-out of closed breaker Independent exhaust vent for all HT compartments Multiple guides for safe, sure and enduring self aligning power contacts Live parts are covered by automatic shutters when breaker is racked out Integral Earthing switch (optional)
...moreHt Panels
Load Break Switch
Switchgear Panels
Ht Panel
Be first to Rate
Rate ThisOpening Hours