Vertical Electrophoresis Equipment
Leak Proof ● No leakage of upper tank buffer as silicone gasket is tough and resilient.● Buffer leaks from plastic joints prevented as sticking is done with special glues.● Leak-proof sealing using agarose in lower tank trough and slotted spacers Economical ● Run upto two gels per side● Short and defined run times as gels can be run at constant current.● Can be run in the refrigerator due to its small footprint. ● Saves reagent and operator cost as leakage and errors are prevented.
...morespecial equipment
Power Supply
Economical ● Four apparatus of similar resistance can be run simultaneously● Reduced maintenance and repairing cost as low probability of burnouts and short circuits ● Less than 10% dissipation of energy as heat. ● No active cooling needed, hence no moving parts which may need to be replaced. Safety ● No shock from accidental contact with single output due to high insulation between primary and secondary windings of transformers● Short circuit proof due to special motherboard design
...moreHorizontal Electrophoresis
Leak Proof � Buffer does not leak from plastic joints as sticking is done with special glues.� Crazing of plastic is minimized as high quality plastic tolerates short exposure to cleaning reagents used in RNA analysis. � Electrodes do not break as they are thick and platinum is > 99.9% pure.� No electrolytic corrosion of male connector as base is resin filled. � Metal screws do not break with extensive usage. Convenient � Multichannel pipetter compatible combs available.� Comb height can be adjusted.� Gels do not slip out in gel gripping tray. Economical � Saves reagent and operator cost as leakage and errors are prevented.� Run larger number of samples per gel.� Can be run at higher voltages for faster separations
...moreGel Viewing equipment
High Sensitivity Visual detection limit is one ng per compact band of EtBr stained dsDNA due to high intensity of UVA tubesUV-transparent diffuser window allows 85-90% of the UV to pass through Safe No skin burns or damage to retina as UVA tubes emit light similar to light found outdoorsNegligible photo-nicking or photo-bleaching of DNA due to use of lower energy UVA lightsDual (Hi-lo) mode for viewing. Go to high mode only when required
...moreCA Strip/ Slide Electrophoresis
Leak Proof ● Buffer does not leak from plastic joints as sticking is done with special glues.● Crazing of plastic is minimized as high quality plastic tolerates short exposure to cleaning reagents Economical ● Saves reagent and operator cost as leakage and errors are prevented.● Run larger number of samples per strip.● Can be run at higher voltages for faster separations
...moreBlotting apparatus
Efficiency of Transfer Hi-fidelity of transfer as large open surface areas in cassette frame allows unhindered passage of currentShort transfer times as low resistance to passage of current due to cassette frame design and sponge quality Economical Less requirement of bufferShort run times as better efficiency of transfer currentNo cold room required as it can be run in the refrigerator due to its small foot printSaves reagent and operator cost as leakage and errors are prevented
...moreBe first to Rate
Rate This