  • FIVE PASS Design Thermic Fluid Heaters

    FIVE PASS Design Thermic Fluid Heaters

    Get Price Quote

    This design gives highest efficiency ever. The Thermic fluid heater is of VERTICAL construction with Two concentric large diameter helical coil & shell assembly, placed directly on top of the combustion furnace. This ensures that the intense luminous heat of the flame is fully utilized. This is the first, Radiative section comprising of the first 3 passes of hot flue gases.   These gases from radiant coil are then made to pass through a second, convective heat exchanger. This is again made of twin concentric helical coils, placed inside a sturdy M.S. shell having two more distinct passes of hot gases, making the total passes of Flue gases inside the TFH to FIVE. Thus maximum amount of heat is extracted from the flue gases. The gases are then made to pass through the Air prehater & Mechanical dust collector, on way to the chimney through I.D.Fan. A generously designed refractory lined external furnace is provided to ensure high furnace volume and grate area and can ensure rated output on low-grade coal and can easily burn most other fuels such as Lignite, Paddy husk, Fire wood, Bagasse, etc, without any modifications.   The Safety controls and instrumentations provided ensure completely safe operation and provide Audio Visual Alarm and cuts off the combustion in case of abnormal operating Conditions.

    more..
  • Thermic Fluid Kettle

    Thermic Fluid Kettle

    250,000 - 900,000 Per piece

    • Material: Stainless Steel
    • Driven Type: Thermic fulid
    • Automatic Grade: Automatic, Fully Automatic, Semi Automatic
    • Application: Machinery
    • Feature: Durable, Easy Installation, Fully Insulated, Minimal Maintenance, Noiseless Operation, Stable Performance
    • Type: Thermic Fluid Heater
    • Weight: 100-1000kg
    • Temperature: 100-150°C, 150-200°C, 200-250°C, 250-300°C, 50-100°C
    • Capacities: 100 Litters / 150 Litters / 200 Litters Brimful
    • Diameter: 1300mm,
    • Height: 1800mm
    more..
  • Best Deals from Thermic Fluid Heater

  • AUTOMATIC THERMIC FLUID HEATER

    AUTOMATIC THERMIC FLUID HEATER

    Get Price Quote

    TECHNICAL SPECIFICATION i - Type – Vertical/Horizontal, 3 pass, Coil Type Thermic Fluid Heater ii - Capacity – 50000 kcal/hr to 2500000 kcal/hr and above iii - Temperature - Up to 300°C and above iv - Fuel - Gas / Diesel/Heavy Oil/ Dual Fuel v - Thermal Efficiency - 88% + 1% based on N.C.V. of Fuels vi - Heat Recovery Unit – Economiser (Optional) vi - Air Preheater - In-built     OPERATION i - Fully automatic operation with BURNER ON-OFF modulation for units up to 40 Lac kcal/hr and HIGH-LOW ON-OFF modulation for higher capacity units keeping FUEL CONSUMPTION in proportion with heat demand in the plant ii - The Burner is pressure atomizing type and is centrally located at the top of the unit iii - Burner is self igniting and maintains CLEAN and SMOKELESS COMBUSTION all throughout the operation iv - Preheated combustion Air gives highest Combustion efficiency maintaining high CO2 % and Low Smoke Index v - Hot Oil circulation pump is of centrifugal type maintaining the circulation of Hot Thermic Fluid through heating coil vi - A Digital Temperature Controller senses the heat demand in the plant and controls the Burner ON-OFF/HIGH-LOW modulation maintaining minimum fuel consumption vii - In case of any abnormal operating condition the SAFETIES provided stop the unit and put the same to SAFETY LOCKOUT CONDITION by giving AUDIBLE ALARM and VISUAL INDICATION     SAFETY FEATURES i - Flame failure device ii - Thermic Fluid low flow tripping iii - Overriding temperature tripping iv - Blow down valve v - Single phasing prevention cum over load for control circuit vi - Miniature Circuit Breaker for control circuit vii - Thermic Fluid level switch on expansion tank (optional) viii - High stack temperature Annunciation/Alarm (optional) ix - Fail Safe Instrumentation x - Control circuit logic ensures Heater going to lock out safety in case of any abnormality in operating condition as well as monitoring instrument failure