Rtd Cables
Get Price Quote
Ptfe insulated rtd cables rtd cables manufactured by bhuwal cables are used as connecting lead wire between rtd sensor and temperature indicator device. Rtd cables are made in 2 core, 3 core, 4 core and 6 core configurations, 3 cores being the most commonly used configuration. Construction: - rtd cables are made in three common constructions for making them suitable for different situations. These are ptfeptfe = this is the most common construction. In this the cores are insulated with ptfe and then cores are twisted and jacketed with ptfe. Ptfefg = in this construction cores are of ptfe and jacket is of fiber glass braid. This is used when rtd cable has to be installed in high temperature environment. Ptfespcptfe: - in this construction a spc wire braid shield is provided between twisted cores and jacket. This type of cable is used where higher accuracy is required. The current and voltage signals in rtd cables are of very small magnitude and can get affected by external electromagnetic noises produced by external devises such as motors, electronic equipments etc near the cable. The spc shield is grounded from one end and this protects the signals in the cable from these external noises.
Thermocouple Compensating Cables
Get Price Quote
Thermocouple wire allow temperatures to be measured electronically. A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, the thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions. We differentiate between thermocouple cable and compensating cable. Cables made of original materials are called extension or thermocouple cables, whereas conductor materials made of substitutes are known as compensating cables.
Best Deals from Thermocouple Cables
Thermocouple Extension Cables
Get Price Quote
These cables can also be termed as instrumentation cables, since they are used for process temperature measurement. The construction is similar to paired instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometers are electrically conducted by thermocouple extension/compensating cables. The conductors used for these cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature. The cables are manu-factured as per IS:8784, ANSI-MC 96. 1, B.S., ENI, DIN and customers specification.
Compensating Cables
Get Price Quote
These cables can also be termed as instrumentation cables, since they are used for process temperature measurement. The construction is similar to paired instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometers are electrically conducted by THERMOCOUPLE EXTENSION/COMPENSATING CABLES. The conductors used for these cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature. The cables are manufactured as per IS:8784, ANSI-MC 96. 1, B.S., ENI, DIN AND CUSTOMERS SPECIFICATION.
Thermocouple and Compensating Cables
Get Price Quote
Different metal pairs generate different emfs which is proportionate to the hot junction and the point where it is measured. Common combination of thermocouple metals and their applicabtions are 1. K-ChromeVAlumel-Most commonly used 2.T-Copper/Constantan-for low temperature & cryogenic applications 3.J-iron/Constantan-Used in reducing atmosphere. 4.E-Chromel/Constantan-Highest EMF output. 5.R-(Platinum-13% Rhodium) / Platinum & S-(Platinum-10% Rhodium) / Platinum-Very High Temperature measurements. 6. B--(Platinum - 30% Rhodium) / Platinum-Mainly used in glass industry. Different colour codes of cores and sheathing as per international practices are used to denote the various thermocouple cables. . COMPENSATING CABLES Extention Leads of different metals but having similar EME output between 0°C to 100°C connected between Thermocouple metals junction and the measuring instruments arc called Compensating Cables which are generally recommended as solid conductor leads.
Thermocouple Compensating Cables
Get Price Quote
In the cables, varied EMFs are generated with different metal pairs that are further proportional to hot junction and the point where it is measured. All these cables are available in different color codes or cores and sheathing as per the international standards.. Description:- Extension leads of different metals but having similar EMF output between 0°c to 100°c connected between Thermocouple metals junction and the measuring instruments are called compensating cables which are generally recommended as solid conductor leads. Application:- Different metal pairs generate different EMFs which is proportionate to the hot junction and the point where it is measured. Common combination of thermocouple metals. Available Range:- K-Chromel/AIumel-Most commonly used. T-Copper /Constantan- for low temperature & cryogenic applications. J-Iron/ Constantan-Used in reducing atmosphere E -Chromel/ Constantan-Highest EMF output. R-(Platinum-13% Rhodium)/ Platinum & S-(Platinum-10% Rhodium) / Platinum-very High temperature measurements. R-(Platinum-13% Rhodium)/ Platinum & S-(Platinum-10% Rhodium) / Platinum-very High temperature measurements. B- (Platinum-30% Rhodium)/ Platinum mainly used in glass industry. Different color codes of cores and sheathing as per international practices are used to denote the various thermocouple cables.
Thermocouple Wire
Get Price Quote
PTFE Thermocouple Wire
Get Price Quote
Thermocouple Cables
Get Price Quote
Thermocouple cables consist of the same element material as the thermocouple and are tested for the same temperatures. These BHUWAL special cables are manufactured on customer request. Silicon , fibre-glass, and Stex insulated or sheathed compensating and extension cables are not suitable for outdoor use.
thermocouple power cables
Get Price Quote
We are offering thermocouple power cables.compensating & original wire thermocouple cables pvc, fibre glass, asbestos, teflon silicon rubber, neoprene rubber, shielded and metal braided varieties of j.k.t. And rtd types, fibre glass and asbestose covered cables. Teflon sleeves 0.5 mm dia to 6 mm dia for different wall thickness and different colors.
Compensating Cables
Get Price Quote
Compensating Cables, Temperature Instrument
thermocouple extension wire
Get Price Quote
thermocouple extension wire, Porcelain Ceramic Connectors, diesel glow plugs
K Type Compensating Cable
Get Price Quote
K Type Compensating Cable, Thermocouple Compensating Wire, ptfe cable
Platinum-rhodium Thermocouple Wire
Get Price Quote
Platinum-rhodium Thermocouple Wire, Wires And Strips, thermocouple bare wire
Compensating Cable
Get Price Quote
Compensating Cable, fibre glass, Computer, Power Cables
platinum thermocouple wire
Get Price Quote
platinum thermocouple wire, research service, iridium foil, Iridium Strips
Thermocouple Cables
Get Price Quote
Thermocouple Cables, insulating materials, RODS, Sleeves, Tapes, Silicone
heat tracing cables
Get Price Quote
heat tracing cables, Cerawool Band Heaters, Straight Air Red Heater
heat tracing cables
Get Price Quote
heat tracing cables, Kettle type elements with ejection device
Thermocouple Wire
Get Price Quote
Thermocouple Wire, Sensors, Frp Electric Insulation Material, ss wire
Compensating Cables
Get Price Quote
Compensating Cables, Super Enamelled Copper Winding Wires, Bakelite Rods