Transformers Dealers in Trombay, Mumbai

(123 products available)
  • Power Transformers

    Power Transformers

    Get Price Quote

    • Packaging Type: Wooden Box
    • Speciality: High Efficiency
    • Usage: Industrial, Commercial, Electricity Distribution
    • Type: Step Up Transformer
    • Material: Mild Steel
    • Shape: Racket
    more..
  • 33kV Single & Three Indoor Resin Cast Potential Transformer

    33kV Single & Three Indoor Resin Cast Potential Transformer

    32,500 Per Piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Size: 10cm
    • Thickness: 0.5-1mm
    • Feature: Fine Finished, Light Weight, Long LIfe
    • Finishing: Coated
    • Material: Copper
    • Brand Name: AEL
    • Phase: Single , Three
    more..
  • Best Deals from Transformers

  • Transformer Oil

    Transformer Oil

    90 - 110 Per Litre

    210 Liter (MOQ)

    • Feature: 100% Pure, Quality Tested
    • Application: Transformer
    • Packaging Type: Drum
    • Appearance: Clear and transparent
    • Purity: 100%
    more..
  • Furnace Transformer

    Furnace Transformer

    Get Price Quote

    • Capacity: Up to 2.5 MVA
    • Frequency: 50-60 Hz
    • Input Voltage: Up to 33 KV
    • Output Voltage: As Required
    • Power: 5 to 20,000 KVA
    • Efficiency: 99 %

    If you are looking for a furnace transformer in Mumbai, you are in the right place. Our company Neelkanth based in Maharashtra is the best company for choosing a furnace transformer. By going over the functions, terms and parts of the transformers that we provide to our customers and clients, you will get a closer understanding of the overall use of a furnace. Furnace Transformers The basic function of the furnace transfer is to supply power to the furnace itself. This can reduce the high voltage capacity to a lower voltage output. These furnaces are necessary for the operations of the Arc furnace. This is designed and manufactured to control the furnace such as ignition, timers, circuitry and temperature controls. As the standard voltage out for any residential house is around 120 volts, these transfers will reduce the voltage of the home of the correct amount for use in your furnace. Regulates The Proper Voltage The importance of a transformer in any electrical device is extremely important. If someone fails to regulate the correct voltage according to the circuit breaker or any other type of electrical device, the entire network will start to work improperly. The consequences can result in the tripped breaker, burnt fuses and system shortages. If you keep on forcing the incorrect voltage, the furnace can get damaged and repairing it can be extremely costly. Why Choose Us? We are the best furnace transformer manufacturer in Maharashtra, India. The products that you get in our company are manufactured under the guidance of the experts and professionals of our company. When you are choosing to buy a new furnace, remember to consider the size and where you are installing it like commercial or residential places. If you are installing in a commercial place, you will need a furnace that is large and if you are installing it in your residential area then a standard size furnace is needed. Select carefully and install the furnace of our company in your required area today. If you have any question or query, feel free to call us and speak to our executives.

    more..
  • MAIN TRANSFORMER

    MAIN TRANSFORMER

    Get Price Quote

    DOUBLE WOUND, STEP-DOWN TRANSFORMER MADE FROM HIGH QUALITY ANNAMELED / DPC COPPER WIRE OF CIRCULAR & SQUARE CROSS SELECTION & HAVING CRGO LAMINATION AS CORE. TRANSFORMER CORE IS CYLINDRICALLY DESIGNED TO OVERCOME LOSSES AND ACHIEVE MAXIMUM EFFICIENCY HIGH PACKING FRACTION ENABLES COMPACT TRANSFORMER DESIGN & REDUCES HEATING IN HIGH LOAD CONDITION BALLAST CHOKE IS SINGLE WOUND INDUCTOR MADE OF CRNO LAMINATION &ANAMELED COPPER WIRE SET TO PERFECTION TO CONTROLL CURRENT & VOLTAGE DROP AT PERTICULAR CURRENT LOAD. SETTING ONLY POSSIBLE AT FACTORY.

    more..
  • Transformer Oil

    Transformer Oil

    Get Price Quote

    General Qualities & Characteristics Mex Transformer oil is an uninhibited electrical insulating fluid, for use in electrical systems where rapid heat transmissions and high oxidation stability are required. They meet the specification requirements of IEC 296 class II:1982standard specification.   Applications : Mex Transformer Oil is primarily intended for use in : Transformers, Circuit Breakers, OIl Filed Switches an insulator and are extinguishing agent in switchgear and circuit breakers.    Performance Features Highly resistant to oxidation degradation : It resists the formation of oxidation products that can reduce the ability of the oil to insulate and cool electrical windings   Rapid Heat Transfer- an essential quality in electrical insulating systems.   Compatible with construction materials - Compatible with all common construction materials used in electrical systems.   Outstanding low temperature properties - without the need for pour point depressants.   Available Packaging: 26Ltr, 50Ltr and 210Ltr.

    more..
  • Distribution Transformer

    Distribution Transformer

    Get Price Quote

    • Application: Transfers electrical energy from one circuit to another through inductively coupled conductors the transformer's coils
    • Application: Engineering industry,Medical industry,Infrastructure
    • Brand Name: TRANSPOWER
    • Use: For the electricity distribution at various places
    • Place Of Origin: Pune,Chakan
    • Min. Order Quantity: As Per Client Requirement
    • Condition: Good

    TRANSPOWER SWITCHGEAR INDUSTRIES is the prime manufacturer and exporter of Distribution Transformers, which are worldwide famous for their efficient functioning. Widely used in substations and industrial sectors, our offered Distribution Transformers are highly praised by clients. For that, we are positioned on top among the listed manufacturers and exporters of Distribution Transformers. Used for : Transfers electrical energy from one circuit to another through inductively coupled conductors�the transformer's coils Use : For the electricity distribution at various places Applications : Engineering industry Medical industry Infrastructure

    more..
  • Welding Transformer

    Welding Transformer

    Get Price Quote

    • Application: Welding Metals
    • Weight: 20-30kg
    • Color: Black, Brown
    • Voltage: 440V
    • Automatic Grade: Automatic
    • Power: 3-6kw
    • Driven Type: Electric
    • Warranty: 1year

    We will not let you wait much, as we have trustworthy shipping facilities available to deliver the same in set time. With excellent storage space and shipping facilities, we effortlessly entertain bulk requirements of our respected patrons. We maintain complete records and transactions of the products delivered.

    more..
  • Transformer Oil

    Transformer Oil

    Get Price Quote

    Our well-structured warehouse is properly maintained and equipped with modern amenities, thus assist us wholly in meeting bulk requirements of the customers. Working in close coordination with the genuine logisticians, we dispatch the products in the dedicated time.

    more..
  • toroidal Transformers For Ambilifiers

    toroidal Transformers For Ambilifiers

    Get Price Quote

    5 Piece (MOQ)

    • Country of Origin: India
    • Type: Toroidal Transformers
    • Application: Amplifier, Stabilizer, Voltage Convertor
    • Color: Black, White, Red
    • Feature: Dimensionally Flexible, Energy Efficient, Exsy Mounting, Low Stray Magnetic Fields, Reduced
    • Voltage: 110V, 220V, 230V, 380V
    • Condition: New
    • Power: 1-5kw
    • Driven Type: Electric
    • Phase: Double Phase, Single Phase, Tripple Phase
    • Warranty: 2years
    more..
  • Current Transformer

    Current Transformer

    Get Price Quote

    • Usage: Industrial Use
    • Frequency: 0-50Hz
    • Condition: New
    • Tensile Strength: 0-25Mpa
    • Feature: Easy To Install, Electrical Porcelain, Four Times Stronger, Proper Working, Sturdy Construction, Superior Finish
    • Warrenty: 5yrs

    Located in Maharashtra, India, we are actively functioning as Manufacturer & Supplier of Current Transformers in the nationwide market. These Transformers are precision engineered in line with pre-defined industry standards. Be it small order or a big one, we accomplish safe and swift deliveries. Buyers can rely on us for reasonable prices.

    more..
  • Capacitor In-rush Limiting Reactors

    Capacitor In-rush Limiting Reactors

    Get Price Quote

    The Capacitor In-rush Limiting reactors are used in series with capacitor bank to control the in-rush current and to suppress the harmonics. Normally reactors with 0.2% rating are used for in-rush current limiting on neutral side and 6% for line side. Specific ratings between 0.8% to 13% are used for harmonic suppression.

    more..
  • Digital Tap Position Indicator

    Digital Tap Position Indicator

    Get Price Quote

    neon Digital Tap Position Indicator, type TX-201 is a microcontroller based instrument used to indicate the Tap position of the Power Transformer with On Load Tap-Changer. Microcontroller based design. Automatic detection of Number of Taps. 1 K Ohms / Step Resistance or User defined. Flicker Free and clear Seven segment LED display for long distance viewing. 4-20mA DC Current Single \ Dual Output for SCADA connectivity.

    more..
  • Welding Transformer

    Welding Transformer

    8,000 Per Piece

    1 Piece(s) (MOQ)

    • Warrenty: 1 Year
    • Phase: Three Phase
    • Cooling Type: Dry Type/Air Cooled
    • Output Voltage: 300
    • No of Cylinders: 2
    • Features: Robust, Corrosion resistant, Durable
    more..
  • Crgo Laminations

    Crgo Laminations

    100 - 250 Per kgs

    • Type: Crgo Lamination
    • Shape: Coil, EI Lamination
    • Thickness: 0.10-0.50mm, 0.50-0.80
    • Application: Industrial Transformer, Power Supply Transformer
    • Color: Grey
    • Surface Treatment: Coated
    • Country of Origin: India

    We are manufacturers and dealers ofcrgo and crngo material

    more..
  • Used Transformer Oil

    Used Transformer Oil

    Get Price Quote

    APAR pioneered the manufacture of internationally benchmarked grades of high performance Transformer Oils in India that were more environment friendly and of high performance with higher oxidation stability, lower gassing tendency and non corrosive with ultra low levels of sulphur.

    more..
  • Distribution Transformers

    Distribution Transformers

    Get Price Quote

    A distribution transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. The invention of a practical efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882. If mounted on a utility pole, they are called pole-mount transformers. If the distribution lines are located at ground level or underground, distribution transformers are mounted on concrete pads and locked in steel cases, thus known as pad-mount transformers. Distribution transformers normally have ratings up to 200 kVA, although some national standards can describe units up to 5000 kVA as distribution transformers. Since distribution transformers are energized for 24 hours a day (even when they don't carry any load), reducing iron losses has an important role in their design. As they usually don't operate at full load, they are designed to have maximum efficiency at lower loads. To have a better efficiency, voltage regulation in these transformers should be kept to a minimum. Hence they are designed to have small leakage reactance. A distribution transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. The invention of a practical efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882. If mounted on a utility pole, they are called pole-mount transformers. If the distribution lines are located at ground level or underground, distribution transformers are mounted on concrete pads and locked in steel cases, thus known as pad-mount transformers. Distribution transformers normally have ratings up to 200 kVA, although some national standards can describe units up to 5000 kVA as distribution transformers. Since distribution transformers are energized for 24 hours a day (even when they don't carry any load), reducing iron losses has an important role in their design. As they usually don't operate at full load, they are designed to have maximum efficiency at lower loads. To have a better efficiency, voltage regulation in these transformers should be kept to a minimum. Hence they are designed to have small leakage reactance.

    more..
  • Variable Transformer

    Variable Transformer

    Get Price Quote

    • Application: Power
    • Brand Name: ravistat
    • Certification: ISO 9001 TO 2015
    • Place of Origin: Maharashtra, India
    • Supply Ability: 1000 Piece/Pieces per Month
    • Coil Structure: Toroidal
    • Model Number: 50F-1
    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection. Neutral earthing transformer is having zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply. ONAN /ONAF cooling with conventional pressed steel radiators. The range includes up to 33 KV systems and as per the site requirements. A Earthing ( zigzag) transformer is a special purpose transformer with a zigzag or 'interconnected star' winding connection, such that each output is the vector sum of two phases offset by 120°.  Its applications are for the creation of a missing neutral connection from an un-grounded, 3-phase system to permit the grounding of that neutral to an earth reference pointand also harmonic mitigation, as it can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents, to supply 3-phase power as an autotransformer (serving as the primary and secondary with no isolated circuits), and to supply non-standard phase-shifted 3-phase power. Nine-winding three-phase transformers, typically have 3 primaries and six identical secondary windings which be used in zigzag winding connection as pictured. As with the conventional delta or wye winding configuration three-phase transformer, a standard stand-alone transformer containing only six windings on three cores can also be used in zigzag winding connection, such transformer sometimes being referred to as a zigzag bank. In all cases, six or nine winding, the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core. The second coils are then all tied together to form the neutral and the phases are connected to the primary coils. Each phase, therefore, couples with each other phase and the voltages cancel out. As such, there would be negligible current through the neutral point, which can be tied to ground. Each of the three "limbs" are split into two sections. The two halves of each limb have the equal number of turns and they're wound in opposite directions. With the neutral grounded, during a phase to ground short fault, a third of current returns to the fault current and the remainder must go through two of the three phases when used to derive a grounding point from a delta source. If one phase, or more, faults to earth, the voltage applied to each phase of the transformer is no longer in balance; fluxes in the windings no longer oppose. (Using symmetrical components, this is Ia0 = Ib0 = Ic0.) Zero sequence (earth fault) current exists between the transformer’s neutral to the faulting phase. The purpose of a zigzag transformer in this application is to provide a return path for earth faults on delta-connected systems. With negligible current in the neutral under normal conditions, providing the defective load will be automatically disconnected in a fault condition, an undersized transformer may be used only as short time rating is required (i.e. the transformer can only carry full rated current for, say, 60 s). Impedance should not be too low for desired maximum fault current. Impedance can be added after the secondaries are summed to limit maximum fault currents(the 3Io path). An application example: A combination of Y (wye or star), delta, and zigzag windings may be used to achieve a vector phase shift. For example, an electrical network may have a transmission network of 110 kV/33 kV star/star transformers, with 33 kV/11 kV delta/star for the high voltage distribution network. If a transformation is required directly between the 110 kV/11 kV network an option is to use a 110 kV/11 kV star/delta transformer. The problem is that the 11 kV delta no longer has an earth reference point. Installing a zigzag transformer near the secondary side of the 110 kV/11 kV transformer provides the required earth reference point.

    more..
  • Ultra Isolation Transformer

    Ultra Isolation Transformer

    Get Price Quote

    We are manufacturing & supplying a wide range of ultra isolation transformer in mumbai. All the types of electrical noises, predominantly common mode noises can be eliminated by ultra isolation transformers.

    more..
  • Step down transformer

    Step down transformer

    Get Price Quote

    • Color: Sky Blue, White, Grey
    • Warranty: 1 yr, 2 yr
    • Driven Type: Electrical
    • Packaging Type: Box, Carton
    • Application: Industrial Use
    • Voltage: 0-110 V, 110-220 V, 220-440 V
    • Condition: New, Used
    more..
  • Current Transformers

    Current Transformers

    15,000 Per Piece

    • Type: Current Transformers
    • Usage: Control Panels, Industrial Use
    • Color: Green, Grey, Light Green, Sky Blue
    • Frequency: 0-50Hz, 100-200Hz
    • Operating Type: Fully Automatic
    • Condition: New, Used
    • Feature: Easy To Install, Electrical Porcelain, Four Times Stronger, Proper Working, Sturdy Construction, Superior Finish
    • Current Type: Double Phase, Single Phase, Triple Phase
    • Warrenty: 1yr
    • RATIOS AVAILABLE: 100/5A to 600/5A
    more..
  • Transformer Oil

    Transformer Oil

    Get Price Quote

    • CHARACTERISTICS: Transformer Oil 335
    • Density at 29.5ºC: 0.890
    • Flash Point, ºC (Pensky - Martin closed): 140
    • Pour Point ºC.: Minus 6
    • Kinematic Viscosity at 27ºC, cSt: 27
    • Breakdown Voltage, new unfiltered / after filtration: 30 / 60
    • Corrosive Sulphur: Non-corrosive
    • Oxidation Stability at 100ºC, 164 Hrs.         a) Total Acidity  b) Sludge: a) 0.4  b) 0.1
    • Water Content, ppm: 50
    • Dielectric Dissipation Factor (Tan d) at 90ºC: -
    • Presence of Oxidation Inhibitor.: Nil
    more..
  • K Rated Transformer

    K Rated Transformer

    Get Price Quote

    K Rated Transformer are designed to reduce the heating effect of harmonic currents produced by non-linear loads. A standard transformer is not designed for non linear load and will overheat and fail prematurely when connected to these loads. K- Factor is defined as a ratio between the additional losses due to harmonics and the eddy current losses at 50 Hz.

    more..
  • K Rated Transformer

    Get Price Quote

    Silica Gel Breather, Float Valves, Duplex Plug And Sliding Disc Type Strainer

    more..
  • Oil Cooled Distribution Transformer

    Oil Cooled Distribution Transformer

    5,000 Per Piece

    • Cooling Type: Oil Cooled
    • Power Rating: 1250kVA
    • Number of Phase: 3-Phase
    • Voltage Ratio: 11kV/433V
    more..
  • Power Transformer

    Power Transformer

    Get Price Quote

    • Min. Order Quantity: ,

    Power Transformer is used for isolation between the high voltages to low voltage. Power Transformer may be used for DC Power source, Regulated AC supply for continuous duty. Input may be 600,440,240 or 110V AC, rated up to 10KVA Secondary. The proper size or the VA rating of the Power Transformer is important. Power Transformer will be a determining factor in the life of the transformer, which ultimately will reflect on the proper operation of power devices that it supplies. The methods of selecting transformer VA ratings are applicable to 50 to 10000 VA Power Transformer.Specifications Rating : up to 10KVA Input : 110/230/440 V AC Lamination : CRGO or CRNO

    more..
  • Three Phase Transformer LV Winding

    Three Phase Transformer LV Winding

    Get Price Quote

    • Application: transformer
    • Phase: Three Phase
    • Shape: Round
    • Color: white
    • Brand Name: shankar Brazing
    • Transformer Type: Power Transformer
    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection.Neutral earthing transformer is having zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply.ONAN /ONAF cooling with conventional pressed steel radiators. The range includes up to 33 KV systems and as per the site requirements. A Earthing ( zigzag) transformer is a special purpose transformer with a zigzag or 'interconnected star' winding connection, such that each output is the vector sum of two phases offset by 120�. Its applications are for the creation of a missing neutral connection from an un-grounded, 3-phase system to permit the grounding of that neutral to an earth reference pointand also harmonic mitigation, as it can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents, to supply 3-phase power as an autotransformer (serving as the primary and secondary with no isolated circuits), and to supply non-standard phase-shifted 3-phase power. Nine-winding three-phase transformers, typically have 3 primaries and six identical secondary windings which be used in zigzag winding connection as pictured. As with the conventional delta or wye winding configuration three-phase transformer, a standard stand-alone transformer containing only six windings on three cores can also be used in zigzag winding connection, such transformer sometimes being referred to as a zigzag bank. In all cases, six or nine winding, the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core. The second coils are then all tied together to form the neutral and the phases are connected to the primary coils. Each phase, therefore, couples with each other phase and the voltages cancel out. As such, there would be negligible current through the neutral point, which can be tied to ground. Each of the three "limbs" are split into two sections. The two halves of each limb have the equal number of turns and they're wound in opposite directions. With the neutral grounded, during a phase to ground short fault, a third of current returns to the fault current and the remainder must go through two of the three phases when used to derive a grounding point from a delta source. If one phase, or more, faults to earth, the voltage applied to each phase of the transformer is no longer in balance; fluxes in the windings no longer oppose. (Using symmetrical components, this is Ia0 = Ib0 = Ic0.) Zero sequence (earth fault) current exists between the transformer’s neutral to the faulting phase.The purpose of a zigzag transformer in this application is to provide a return path for earth faults on delta-connected systems. With negligible current in the neutral under normal conditions, providing the defective load will be automatically disconnected in a fault condition, an undersized transformer may be used only as short time rating is required (i.e. the transformer can only carry full rated current for, say, 60 s). Impedance should not be too low for desired maximum fault current. Impedance can be added after the secondaries are summed to limit maximum fault currents(the 3Io path). 

    more..
  • CRGO Assembled Cores

    CRGO Assembled Cores

    Get Price Quote

    we can even provide you built up core / stacked transformer core assembled of mitter as well as rectangular strip cores at our place or even at customers factory as per the requirements. This enables the manufacturer the no wastage and the time saving advantage. crgo core assembly crgo laminations are stacked to form the core assembly as per the design provided by the customer. The core assembly is held rigidly by steel frame clamped together to prevent vibrations. The top and bottom yoke clamping channels are tightened together with tie rods which are duly insulated. The core assembly is provided with lifting lugs suitable for lifting the complete core and coil assembly of the transformer without transmitting stresses to the laminations. features: corrosion resistancea flawless finishoptimum finishdimensional accuracy

    more..
Filter by Locality
top