Distribution Transformers Dealers in Wadala, Mumbai

(12 products available)
  • Single & Three Out Door Oil Cooled Voltage Transformer

    Single & Three Out Door Oil Cooled Voltage Transformer

    Get Price Quote

    1 Piece (MOQ)

    • Country of Origin: India
    • Weight: 10-20kg
    • Voltage: 110V
    • Power: 1-3kw
    • Power: Ac , DC
    • Material: Copper
    • Phase: Single , Three
    • Brand Name: AEL
    • Secondary Voltage: Na

    Following are main factors for selecting Voltage Transformer. Service Voltage:System Voltage in which V.T is to be installed e.g. 11kv, 22kv, 33kv etc. Installation:Whether OUTDOOR or INDOOR Atmospheric Conditions:Such as condition of Pollution, Altitude, Ambient Temperature etc. Insulation Level:If insulation level other than associated with service voltage is required, it should be specifically mentioned. Rated Primary Voltage:Rated primary voltage is generally rated system voltage for unearthed type V.Ts. and rated system voltage divided by square root of three for earthed type V.Ts. The V.Ts. can be manufactured suitable for more than one system voltage. In such cases, different primary voltages required may be indicated. Rated Secondary Voltage:Standard Values of Secondary voltages are 110v or 110v/\13 depending on application of the secondary winding. V.Ts. with different secondary voltages other than those mentioned above can be manufactured and supplied. Voltage Factor:All V.Ts, are manufactured suitable for continuous voltage factor of 1.2. As per I.S. / L.E.C. Specifications, short time voltage factor is different for different earthing systems. Therefore appropriate system earthing conditions may be specified. Number of secondary windings. Their burdens & accuracy classes:Number of secondary windings, their burdens and accuracy classes are selected on the basis of application. Two types of classes are available, one for metering and other for protection. Unlike current transformers, accuracy of one winding is influenced by loading of other winding. Due to this reason burden of each winding should be correctly mentioned. Accuracy of V.T. is guaranteed at the secondary terminals of the V.T. The impedance of cable connecting secondary terminal to load (Relay or Meter) offers series drop in output voltage. This causes additional errors in secondary winding at the measuring end of cable and is proportional to the load on the secondary. Therefore, it is advisable to select separate metering and protection winding. Alternatively, single winding can be used for metering and protection if separate cables are used for connections. (Cable of 4 sq. mm. cross section offer 2% voltage drop at 100 metres distance will 100 VA burden for secondary voltage of 110v/A).  

    more..
  • Distribution Transformers

    Distribution Transformers

    Get Price Quote

    A distribution transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. The invention of a practical efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882. If mounted on a utility pole, they are called pole-mount transformers. If the distribution lines are located at ground level or underground, distribution transformers are mounted on concrete pads and locked in steel cases, thus known as pad-mount transformers. Distribution transformers normally have ratings up to 200 kVA, although some national standards can describe units up to 5000 kVA as distribution transformers. Since distribution transformers are energized for 24 hours a day (even when they don't carry any load), reducing iron losses has an important role in their design. As they usually don't operate at full load, they are designed to have maximum efficiency at lower loads. To have a better efficiency, voltage regulation in these transformers should be kept to a minimum. Hence they are designed to have small leakage reactance. A distribution transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. The invention of a practical efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882. If mounted on a utility pole, they are called pole-mount transformers. If the distribution lines are located at ground level or underground, distribution transformers are mounted on concrete pads and locked in steel cases, thus known as pad-mount transformers. Distribution transformers normally have ratings up to 200 kVA, although some national standards can describe units up to 5000 kVA as distribution transformers. Since distribution transformers are energized for 24 hours a day (even when they don't carry any load), reducing iron losses has an important role in their design. As they usually don't operate at full load, they are designed to have maximum efficiency at lower loads. To have a better efficiency, voltage regulation in these transformers should be kept to a minimum. Hence they are designed to have small leakage reactance.

    more..
  • Best Deals from Distribution Transformer

  • Compact Sub Station

    Compact Sub Station

    Get Price Quote

    The CSS are designed, manufactured, fully assembled, wired and operationally tested in our workshops, therefore site works are minimal. The CSS are compact and consist of power factor correction equipment, ring main unit / load break switch, circuit breakers, switchboards and dry / oil type transformers encased in robust enclosures with easy access to equipment. The CSS can be ideally installed in residential and commercial complexes, industrial environments, utilities where free space is a major constraint. Features Factory built and testedEasy and simple to install reducing the on-site operationsReady for network connectionDesign complies to IEC 61330Maintenance free SF6 insulated Ring Main Unit for MV networkingSCADA compatible equipmentsAvailable with oil cooled/dry type transformers upto 2500kVARust, corrosion and weather proof enclosureIndependent access for all the compartments for routine maintenance

    more..
  • Compact Substation

    Compact Substation

    Get Price Quote

    he CSS are designed, manufactured, fully assembled, wired and operationally tested in our workshops, therefore site works are minimal. The CSS are compact and consist of power factor correction equipment, ring main unit / load break switch, circuit breakers, switchboards and dry / oil type transformers encased in robust enclosures with easy access to equipment. The CSS can be ideally installed in residential and commercial complexes, industrial environments, utilities where free space is a major constraint. FeaturesFactory built and testedEasy and simple to install reducing the on-site operationsReady for network connectionDesign complies to IEC 61330Maintenance free SF6 insulated Ring Main Unit for MV networkingSCADA compatible equipmentsAvailable with oil cooled/dry type transformers upto 2500kVARust, corrosion and weather proof enclosureIndependent access for all the compartments for routine maintenance

    more..
  • Power Transformer

    Power Transformer

    500 - 2,000 Per piece

    100 Piece (MOQ)

    • Country of Origin: India
    • Voltage: 220 V
    • Finishing: Polished
    • Power: 10 KW
    • Driven Type: Electric
    • Warranty: 1 Year
    • Certification: ISO 9001:2015, ISO 13485:2016, AS 9100 Rev D
    • Packaging Type: Wooden Box
    • Overall Length: 10-15 Inch
    • Speciality: Robust Construction, Easy To Use, High Efficiency
    more..
  • Hermetically Sealed Transformer

    Hermetically Sealed Transformer

    Get Price Quote

    Hermetically Sealed Transformer, Distribution Transformers

    more..
  • Auxiliary Transformer

    Auxiliary Transformer

    Get Price Quote

    The Unit Auxiliary Transformer is the Power Transformer that provides power to the auxiliary equipment of a power generating station during its normal operation. This transformer is connected directly to the generator out-put by a tap-off of the isolated phase bus duct and thus becomes cheapest source of power to the generating station. It is generally a three-winding transformer i.e. one primary and two separate secondary windings. Primary winding of UAT is equal to the main generator voltage rating. The secondary windings can have same or different voltages i.e. generally 11KV and or 6.9KV as per plant layout.

    more..
  • Oil Filled Transformers

    Oil Filled Transformers

    Get Price Quote

    Oil Filled Transformers, Induction Furnace Transformers, lighting transformers

    more..
  • Hermetically Sealed Transformer

    Get Price Quote

    Hermetically Sealed Transformer

    more..
  • Pole mounted Transformer

    Get Price Quote

    Pole mounted Transformer, Power Flow Analysis, ehv cable laying work

    more..
  • Distribution Transformers

    Get Price Quote

    Distribution Transformers, AC Drive > MFDDTB3A2 (5KW), Switch Gear

    more..
  • Ht Substation

    Get Price Quote

    Ht Substation, LT Substation, high voltage motor, Low Voltage Motor

    more..