Two Wire Temperature Transmitter
Get Price Quote
We are engaged in offering Two Wire Temperature Transmitter. Which are designed to fit inside many compact thermo well protection heads. These products are in huge demand all over the world due to compact sizes.
2 Wire Temperature Transmitter
Get Price Quote
Isolated transmitters 1000/1500 VRMS isolation 12-36 VDC power supply True 2-wire transmitter Ground loop elimination DIN RAIL Mounting : 75H x 46W x 110D, mm.
Best Deals from Transmitter Device
Pressure Transmitters
Get Price Quote
Low Cost - High Performace Model +/- 0.25% upto 0.1% F.S. Accuracy All Ranges from 1 bar upto 1000 bar / -1 to 0 /& -1x1, -1x3, -1x5, -1x6, -1x9, -1 to 10, -1 to 20 bar Operating Temp upto +125 deg C Available Ex-stock MAKE : GEMS / MEAS / AST / PRIGNITZ Application Pressure Transmitter is widely used for industrial automation applications. The transmitters gives output of 4-20mA current signal which can be connected to a Controller / PLC for control/monitoring of pressure. We also offer customized solutions for applications like hygenic
Pressure Transmitters
Get Price Quote
we are offering pressure transmitter is widely used for industrial automation applications. the transmitters op's a 4-20ma current signal which can be connected to a controller plc for controlmonitoring of pressure.
Pressure Transmitter
Get Price Quote
Offering Pressure Transmitter with various diaphragm seals. We also undertake job of attaching diaphragm seals to your pressure transmittersgaugesswitches.
Toxic Gas Transmitter
Get Price Quote
We are one of the leading Manufacturers and Suppliers of Toxic Gas Transmitters in Mumbai. Toxic Gas Transmitter 1000D is a series of direct use sensor-transmitter combination units housed in weatherproof (IP65) enclosures. Alternately, Toxic Gas Transmitter is also available in FLP version suitable for hazardous areas (IIA/IIB). Toxic Gas Transmitters are designed for standard two wire operation where the output is supplied via the same wire pair as the power supply. The external circuit loop is connected to the Toxic Gas Transmitter through a screw terminal connector. The units are supplied pre-calibrated for the specified range, and the sensitivity of the device should not drift by more than 2% of full signal per month. Some sensors have cross interference effect of other gases. It is important to specify air composition to help choose appropriate sensor for the Toxic Gas Transmitter. Features Of Toxic Gas Transmitter Can be operated over a wide power supply range (Nominal 24 V DC) Total loop resistance in external circuit depends upon the operating voltage Maximum loop resistance includes measuring resistor at the remote receivers and any series meters for calibration Sensors require just few seconds to settle after start-up Some models (analog type) provided with potentiometers for routine span and zero adjustment Except requiring periodic recalibration, transmitters are maintenance-free Provide faultless service throughout the working life of the sensor Circuit uses SMD and microcontroller based design to provide excellent linearity, accuracy and stability Circuit imposes no constraints on the sensor Performance characteristics of sensor are unaltered by addition of circuit board Optional Enhancements For Toxic Gas Transmitter 4 digit LCD display Multi-parameter back lit LCD display HART protocol output Modbus protocol PC calibration Programming facility Highlights Very low maintenance 4 digit LED display Microcontroller SMD components Weather proof dust tight IP 66 enclosure Aesthetical looks 2 wire 4-20 mA output Compatible : DCS, PLC, PRISM Monitors Loop powered wide OPTG voltage High sensitivity sensor Connections To Controller Use Positive and Signal terminals of the controller Controller must have a loop shunt resistor Max. Loop resistance with 24 V supply is 500 ohms including cable resistance Do not connect ´N ´terminal. This is for service personnel only
Intelligent Pressure Transmitter
Get Price Quote
Product Description ± 0.04% high performance option; ± 0.2% of URL stability; 120:1 rangeability; Span as small as 50 Pa (0.2 inH2O) up to a range limit of 40 MPa (5800 psi); Up to 52 MPa static pressure (7500 psi); Direct digital capacitance sensing (no A/D conversion); True non-interactive zero and span; Local zero and span adjustment; Remote calibration and parameterization; Transfer functions: linear, V x, V x3 e V x5 ; Tank linearization; Alphanumerical LCD indication; Small and lightweight; Explosion proof and weather proof housing approved (IP66/68 or IP66/68W); Intrinsically safe certification; Signal simulation for loop tests; Non-volatile flow totalization; Configurable user unit; Configurable local adjustment; EMC (Electromagnetic Compatibility) according to IEC61326-1:2006, IEC61326-2-3:2006, IEC61000-6-4:2006, IEC61000-6-2:2005; Write protection function; HART – 4 to 20 mA Update output current in 100 ms with 0.75 μA resolution; Improved performance due to dedicated math co-processor; Multidrop operation mode; PID control function; Supports DTM and EDDL; Bi-directional flow measurement; With FMEDA analysis and MTBF of 244 years.
Temperature Transmitters
Get Price Quote
Digital Temperature Controller, Digital Counter, Digital Timers