Wolters Kluwer India Pvt. Ltd. Marol, Mumbai, Haryana

  • Urine rim Test

    Urine rim Test

    Request for Price

    The hemogram suggested mild leukocytosis with neutrophilia and the urine showed red blood cells, some of which were sickled. The patient was advised hemoglobin electrophoresis which suggested sickle cell trait (Hb-AS). We conclude that sickled erythrocytes should not be ignored in a sample of urine as it may serve as an important clue to the diagnosis of sickle cell trait or disease.

    ...more
    Get Best Price
  • SALACIA OBLONGA

    SALACIA OBLONGA

    Request for Price

    We can provide desired results with guaranteed correctness only to humans. Therefore, we need to verify that you are a human and not a computer. This website has been inundated with requests from remote servers instead of people, which caused a high load. By forcing this captcha on you, we can ensure that we offer you desired results.

    ...more
    Get Best Price
  • nasogastric tube

    nasogastric tube

    Request for Price

    Levins tube is used for Gastro intestinal drainage.Manufactured from non toxic, medical grade PVC compound.Distal end is coned with four lateral eyes for efficient drainage. The tube is marked at 45, 55, 65 and 75 cm from the distal end for accurate placement into the abdomen.

    ...more
    Get Best Price
  • kidney pills

    kidney pills

    Request for Price

    The journal publishes original papers and reviews on cell therapy and islet transplantation, clinical transplantation, experimental transplantation, immunobiology and genomics and xenotransplantation related to the kidney. The journal also publishes short communications, case studies, letters to the editors, an annotated bibliography and a column on news and views.Journal is published Bimonthly.

    ...more
    Get Best Price
  • Iron Folic Acid Tablet

    Iron Folic Acid Tablet

    Request for Price

    Backed by rich professionals, we have established ourselves as a trustworthy manufacturer of a qualitative assortment of Elemental Iron Folic Acid And Zinc Tablets.

    ...more
    Get Best Price
  • ILizarov External Fixator

    ILizarov External Fixator

    Request for Price

    Ilizarov External Fixator offered provides usage as most stable external fixation for distal tibial fractures.Solutions comprise fully circular rings with 3 or 4 connecting rods between each rings, The ring with tensioned wires comes attached to distal tibial articular segment.

    ...more
    Get Best Price
  • humerus nail

    humerus nail

    Request for Price

    Segmental fractures of humerus are difficult to treat. Various options exist for treating ipsilateral metadiaphyseal fractures of humerus but have their own set of complications. Management of these fractures with long angular stable plates gives us an advantage of treating these two level fractures simultaneously thereby reducing complications and postoperative morbidity. Applying minimally invasive plate osteosynthesis (MIPO) principles helps in the biological healing of fracture by being minimally invasive and preserving blood supply to the soft tissues. We are presenting a small series of ipsilateral metadiaphyseal fractures humerus using long angular stable plates in an MIPO fashion.

    ...more
    Get Best Price
  • femoral nails

    femoral nails

    Request for Price

    The patients were followed regularly for a period of two years. These fractures were fixed with proximal femoral nail. The final outcome measurement was done according to Harris hip scoring (HHS) method of functional assessment. Results: Sixty three percent of cases of our study presented with non union and 37% showed osseous union of which three were of basal type and five were of transcervical type. Out of the 22 patients assessed according to Harris hip score only 27.24% cases showed good result whereas 63.56% cases showed poor results. Results based on the anatomical type of fracture showed basal type of fractures with good results of union while 73.68% of the transcervical type of fractures showed poor results. Fair results were seen in 10.25% while only 15.26% of the patients showed good results in transcervical type of fractures. Good results obtained in transcervical type of fracture were the ones associated with subtrochanteric fracture femur. The purely transcervical type of fracture showed fair results in only two patients while the rest showed non union. Conclusions: After conduction of this study on results of the treatment of intracapsular fracture neck of femur by proximal femoral nailing we conclude that (A) proximal femoral nail is useful in basal type of fracture and in those types of transcervical fractures which are associated with ipsilateral subtrochanteric fracture. (B) Proximal femoral nail should be avoided in pure transcervical fracture neck of femur.

    ...more
    Get Best Price
  • Fan Retractor

    Fan Retractor

    Request for Price

    In few centers, LLDN, particularly on the right side, is performed through retroperitoneal approach but working space is limited and sub-capsular hematomas may occur due to prolonged pressure by fan retractor. [15]

    ...more
    Get Best Price
  • dialysis fluid

    dialysis fluid

    Request for Price

    dialysis fluid we need to verify that you are a human and not a computer. This website has been inundated with requests from remote servers instead of people, which caused a high load. By forcing this captcha on you, we can ensure that we offer you desired results.

    ...more
    Get Best Price
  • Cystoscope Sheath

    Cystoscope Sheath

    Request for Price

    We have been counted amongst the most trusted names in this domain, engaged in providing Cystoscope Sheath.

    ...more
    Get Best Price
  • Cystoscope

    Cystoscope

    Request for Price

    We are offering an extensive range of Cystoscopes is made of optimum quality stainless steel by our esteemed vendors.

    ...more
    Get Best Price
  • cranial mesh

    cranial mesh

    Request for Price

    Using premium packaging materials, we secure our products properly for transportation and label it properly to provide information such as address of manufacturerdistributors, MRP, quantity, etc. We follow stringent quality measures to ensuring the product quality so as to attain maximum client satisfaction.

    ...more
    Get Best Price
  • Bone Cement

    Bone Cement

    Request for Price

    Chronic osteomyelitis is a dreaded sequel to acute haematogenous osteomyelitis. It is also more frequent following open fracture and orthopedic surgeries. Principle in treatment of chronic osteomyelitis based on removal of devitalized tissue and filling up of dead space. Systemic antibiotic therapy may not provide minimum inhibitory concentration for prolong period. Antibiotic laden bone cement can be used in adjunct to usual treatment of debridement and systemic antibiotic therapy for local antibiotic delivery and filling dead space temporarily. Material and Method: 32 cases of chronic osteomyelitis (7 haematogenous and 25 exogenous following trauma or surgery) were included in our study which included 21 male and 9 female, age ranging from 18 to 55 year. Pre-operative culture from sinus tract, ESR, and CRP were done. All patient were treated with debridement and removal of implant if present, followed by filling the dead space by antibiotic laden bone cement beads or antibiotic laden bone cement coated nail. Control of infection was assessed by laboratory parameter. Antibiotic cement was removed at an average of 10.62 weeks. All patients were followed up for at least 2 years. Result: Infection was controlled in 28 patients out of 32 patients at the time of cement removal, secondary procedure was done in all patients of infected non union in the form of bone grafting and definite fixation except 3 patients where antibiotic cement coated nails are retained till union as there was callus formation at the end of three month. Conclusion: Antibiotic laden cement is an effective method in local control of infection in chronic osteomyelitis without any systemic side effect.

    ...more
    Get Best Price
  • Biopsy Gun

    Biopsy Gun

    Request for Price

    To determine the diagnostic quality and complication rates of 16G and 18G needles in biopsy of the kidney, we performed renal biopsy using a biopsy gun under ultrasound guidance in 50 patients who were prospectively and evenly assigned to one of the two needle biopsy

    ...more
    Get Best Price
  • Benzocaine

    Benzocaine

    Request for Price

    The objective of this study was to determine the pain produced from needle insertion at bilateral labial site prepared with topical application of 2% lidocaine gel, 20% benzocaine gel, and placebo paste at subsequent visits in a same patient.

    ...more
    Get Best Price
  • Apex Locator

    Apex Locator

    Request for Price

    The apical constriction where the pulp is linked to the apical periodontal tissue referred to as the minor diameter is recommended by many as the appropriate landmark where root canal preparation and obturation should terminate.

    ...more
    Get Best Price
  • Antiviral Drugs

    Antiviral Drugs

    Request for Price

    Hepatitis C virus (HCV) is a significant problem among hemodialysis population, especially in India where renal transplant often gets delayed in the presence of live-related donors. An acceleration of liver cirrhosis and poor renal allograft outcomes are often witnessed in allograft recipients with high viral load. Use of interferon in the postrenal transplant setting for the treatment of hepatitis C viral infection was limited to a few grave situations, fearing the precipitation of allograft rejection and poor efficacy for sustained virological remission. However, the availability of newer direct-acting antivirals has opened a new tool box in the management of HCV in the postrenal transplant setting and in reducing the pretransplant waiting period.

    ...more
    Get Best Price
  • Antiviral Agents

    Antiviral Agents

    Request for Price

    We can provide desired results with guaranteed correctness only to humans. Therefore, we need to verify that you are a human and not a computer. This website has been inundated with requests from remote servers instead of people, which caused a high load. By forcing this captcha on you, we can ensure that we offer you desired results.

    ...more
    Get Best Price

Services

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Service Providers / Wholesale Suppliers
  • Year of Establishment 1998
  • Ownership Type Professional Association

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Cch ifirm is software based on advancement in technology innovations and ideas this concept is very much a reality nowadays with numerous document management software’s for chartered accountants. Soft copies have many advantages over physical files and document folders. In present day and age, the benefits of electronically document management for accountants are far too many and far too evident. the prime concept of overall document management for accountants is to provide and entrust you with the power to easy access from anywhere and anytime. The software enables you to access your valuable clients’ files through a simple click on the contact record. 70% of cch ifirm’s chartered accounting and management practice consulting firms who used the software at least two to three times per week reported improved internal teamwork and communication.
the business will be more profitable when you maintain existing customers while looking for new ones. When you have workflow management software installed, the job becomes easier. You will able to manage your clients’ information and data more effectively and establish proper uninterrupted communication with them and building customer loyalty in the process.
Read More »

Contact Information

Wolters Kluwer India Pvt. Ltd.

  • Ms. Wolters Kluwer India Pvt. Ltd.
  • A-202, 2nd Floor The Qube, C.T.S. No.1498A/2 Village Marol, Andheri (East), Mumbai, Maharashtra

Find Popular Cystoscope Dealers

top