voltage relays
Operations of the relay can be tested by means of a test, button which energies the output relays & LED’s after set time delay with the channels set to underover frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated, ARMO UFT frequency relays are used to monitor the frequency of an electrical system. Due to inadvertent splitting of inner connection in power system, isolated areas of the system may become deficient in the generation & frequency of the same may drop considerably giving rise to emergency conditions.
...moreUninterruptible Power Supply
1:1 1-6 KVA 1:1 & 3:1 10-20KVA UPS SYSTEMS ARMO Green power is an ideal solution for IT systems, Telecommunications equipment & mission critical systems such as safety devices, ensuring maximum power reliability. ARMO green power is designed & built using state-of-the-art technology & components to provide maximum protection to the powered loads with no impact on downstream systems & optimised energy savings. Green power UPS includes 6 KVA single/single-phase & Three/Single-phase models. With online double conversion technology the load is powered continuously by the inverter which supplies a Sinusoidal voltage, filtered & stabilized in terms of form & frequency. Input & output filters provide significant further immunity from mains disturbances & lightning strikes. In terms of technology & performance, ARMO green power is one of the best UPS available on the market today: custom diagnostics LCD display, RS 232 & USB interfaces with software, ESD input, Interface slot with optional boards. Highlight ( 1:1 1-6 KVA ) Small Footprint Power Factor 0.9 High Efficiency 96-97% Parallel able 1+1 Simplified Installation High Quality Output Voltage Application ( 1:1 1-6 KVA ) Data Centres E-Medical Industry Transport Emergency House hold appliances
...moreUndervoltage Relay
Internal event recording of last three event. The values of parameters at the moment of tripping are recorded on the display.Internal timers are provided for each operating circuits & separate aux. Relays ensure maximum flexibility of operation.ARMO UFT relay is used to detect such condition & initiate load shedding to prevent complete system collapse.
...moreTripping Relay
We already have a wide network of Distributors & Dealers all over the country. They all have sufficient trained manpower with them which ensures best support to our customer. The process of appointing dealers distributors in unrepresented areas is on and continuous efforts are made to expand our base on this line.
...moreTransformer terminal
It prevents transfer of RF and HF disturbances with extensive insulation between primary and secondary. The insulation levels withstands HV breakdown strength of 2.5 KV and gives a DC galvanic isolation of above 1000 mega ohms.Isolation Transformer shall invariably be in one air cooled section.
...moreTransformer enclosures
The enclosures are constructed from MS angles and CRCA MS sheets of best quality of reputed make only. This is ensured by an Ultra Isolation Transformer (UIT). It provides for total electrical and electro static isolation with most effective screening of spikes, surges and transients. Further, it gives a true isolated local neutral and dedicated earth which are very essential for modern machines.
...moreStep Up-Step down
These transformers steps down or steps up voltage viz. 230 to 110 V or 440 to 220 V etc. They are available in auto wound or double wound constructions and in rating up to 500 KVA (for Single phase and three phase)
...moresinewave inverter
Unreliable Power supply should not damage your costly equipments. ARMO the leaders in power protection bring you India’s most reliable inverter. Get an ARMO Inverter today and say goodbye to power cuts! Pure sine wave technology One year on site comprehensive warranty including battery. Compact and aesthetic design. Child and shock proof features offering complete safety. Acid resistant body and battery cabinet optional. SALIENT FEATURES Spike Protection - MOV (Metal oxide Varistor) spike suppressor mounted on the AC input damps any spike over 200% of nominal input voltage with transit response time of 25ns.(A standard surge voltage measures 40 micro sec. in width.) Battery Low Protection and Auto Restart - The invertor supplies when line power is not available. To avoid battery Damage from over discharge, the generator shuts down automatically. The unit automatically restarts when the AC line is normal. Overload /Short Circuit Protection - The inbuilt electronic sensing circuitry gets activated when the generator is on backup & overload or short circuit occurs. The Overload condition is latched till the mains resumes or is manually reset. The internal fuse protects the wall outlet from damage due to overload or short circuit when generator is on mains. Charger Trip Protections - If no Battery or dead battery is connected, generators will check for voltage at battery connectors. If it is less than specified voltage (i.e. 4 volts x no. of batteries) Charger will be Tripped to avoid over loading and charger trip light on front panel will glow. Charger - Sophisticated Constant Voltage current limit (CVCL) charger to avoid over charging is also provided. This also assures full charging within expected time, even when mains supply is very low (170V).This assures full backup.
...morePure Sine Wave Power Inverter
Charger Trip Protections - If no Battery or dead battery is connected, generators will check for voltage at battery connectors. If it is less than specified voltage (i.e. 4 volts x no. of batteries) Charger will be Tripped to avoid over loading and charger trip light on front panel will glow.One year on site comprehensive warranty including battery.Compact and aesthetic design.
...morePhase Conversion
These transformers are used for connecting heavy Single phase load from three phase supply. Winding are Open Delta or Inter Star connected.
...moreOpen delta transformer
These transformers are used for connecting heavy Single phase load from three phase supply. Winding are Open Delta or Inter Star connected.
...moreNumerical under frequency relay
A switch is provided to select either an independent made of operation of three or four channels or select the under/over frequency made of operation. The test switch, tripping indications & reset button are provided on the front of Relay. The relays are suitable for any application in industrial plants & to generators where definite time under/over frequency protection is required Internal timers are provided for each operating circuits & separate aux. Relays ensure maximum flexibility of operation. Internal event recording of last three event. The values of parameters at the moment of tripping are recorded on the display. Two terminals are provided for the voltage input to the frequency sensing circuit the measurement of the frequency is digital for which only the zero crossing of the system voltage & not its amplitude are of consequence the relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs. Operations of the relay can be tested by means of a test, button which energies the output relays & LED’s after set time delay with the channels set to under/over frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated Features Low Burden Wide operating voltage range Wide frequency setting range 39. 00 to 70. 00 Hz Independently adjustable tripping stages. Consistent accuracy (± .03 Hz) Unaffected by voltage fluctuations Insensitive to harmonics & transient Built in timer(.1 to 99.9 Sec.) Built in event recorder for last three events. Under frequency & over frequency relay with 2 to 4 frequency stages. Adjustable under voltage blocking level. Field Adjustable relay rated frequency One operate time can give to each frequency stage. Protection stages can be separately blocked via internal blocking inputs.
...moreNumeric Servo Stabilizer
The Performances of any electrical equipment is optimum at its rated Voltage. Both, over Voltage and under-voltage produce harmful effects .Under-Voltage generally reduces efficacy. Whereas over voltage Shortens life. The ARMO Numerical Servo controlled Voltage Stabilizers have been specially designed incorporating the latest in solid state Technology to protect your equipment from harms caused by undesirables Voltage Fluctuations. Salient Features No Wave form distortion. Low internal impedance. High Speed correction rate. Especially numerical Designed Voltage Sensing circuit. Output Independent of nature of load, Value of load Q power Factors. Under and over voltage cut. Special Features Alphabetical LCD display for displaying parameters & messages. Load on & Mains on indication. Inbuilt Phase sequence detector Alarm for fault occurrences. Protection against Over Voltage, Under Voltage, Overload Condition. Enhanced voltage Correction rate Controlled by micro controller. Settable required voltage within range of 380V-420V factory setting. Equipped with advance data logger for storage of fault history.
...moreLow Voltage Transformer
These are used for the inspection of hand lamps etc. and are preferably for low voltages. ARMO manufactures transformers for stepping down the 230 volts line supply to 24 V, suitable for hand lamps. These transformers are of single phase double wound construction.
...moreLighting Transformer
These transformers rectify the fluctuation in line voltage. They are available for both single and three phase supplies and in any capacity up to 500 KVA. For single phase supply the normal input is between 180 to 250 V, output being 240 V. For three phase supply the input is between 380 to 440 V, and output 415 V. They are also custom manufactured as per the specifications and needs.
...moreIsolation Transformer
Any Double Wound Transformer is inherently an ISOLATION TRANSFORMER as the primary and secondary are isolated from one another through insulation. However, modern machines and systems need a truly isolated, clean and stable power requirement. This is ensured by an Ultra Isolation Transformer (UIT). It provides for total electrical and electro static isolation with most effective screening of spikes, surges and transients. Further, it gives a true isolated local neutral and dedicated earth which are very essential for modern machines. Ultra Isolation Transformer attenuates common mode noise and transverse mode noise and provides for noise or interference free power. In principle, UIT only transfers 50 Hz power by transformer action through mutual inductance. It prevents transfer of RF and HF disturbances with extensive insulation between primary and secondary. The insulation levels withstands HV breakdown strength of 2.5 KV and gives a DC galvanic isolation of above 1000 mega ohms.
Voltage : : 415 V AC +/- 10%
Voltage : : 415 V AC, 3 PHASE
Enclosure : : ENCLOSED IN SHEET METAL STRUCTURE OF ADEQUATE THICKNESS WITH LOUVRES FOR VENTILATION AND WHEELS FOR MOBILITY
...moreInverter Cabinet
Charger Trip Protections - If no Battery or dead battery is connected, generators will check for voltage at battery connectors. If it is less than specified voltage (i.e. 4 volts x no. of batteries) Charger will be Tripped to avoid over loading and charger trip light on front panel will glow.Child and shock proof features offering complete safety.Acid resistant body and battery cabinet optional.
...moreInverter Battery Charger
Spike Protection - MOV (Metal oxide Varistor) spike suppressor mounted on the AC input damps any spike over 200% of nominal input voltage with transit response time of 25ns.One year on site comprehensive warranty including battery.
...moreIndustrial Battery Chargers
Free standing steel cabinet 1.62.0 mm gauge sheet steel or as per customer requirement.Programmable Timer for 7153045 days with selectable Time of 15304560 mins. for automatic charge and discharge cycle.Cubical lamp, voltmeters, control ckt, condenser protection by HRC fuses.
...moreFrequency Trend Relay
ARMO-UFTR Frequency relays are used-to monitor the frequency of an electrical System. Due to inadvertent splitting of inner connection in power system. Isolated areas of the system may become deficient in the generation and frequency of the same may drop considerably giving rise to emergency conditions. In order to maintain control of system under this low frequency emergency,some form of graded load shedding is needed. ARMO-UFTR relay is used to detect such conditions and initiate load shedding to prevent complete system collapse. Type UFTR-41 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage. Type UFTR-51 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage. Separate Auxiliary relays are provided which get energized after the respective time delays (In case of df/dt the tripping frequency gradient). Tripping indications and reset push button are provided on the front of the relay. The relays are suitable for any application in industrial plants and to generators where definite time under over frequency protection with df/dt stage is required. Internal timers are provided for each operating circuits and separate aux relays ensure maximum flexibility of application. Two terminals are provided for the voltage input to the frequency sensing circuit. The measurement of the frequency is digital for which only the zero-crossing of the system voltage and not its amplitude, are of consequence. The relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs Silent Features Low burden Wide operating voltage range Wide frequency setting range 39.00 to 70.00 Hz Independently adjustable tripping stages two of which have a rate of change of frequency function. Consistent accuracy = +-0.03 Hz at 50 Hz Unaffected by voltage fluctuations Insensitive to harmonics & Transient Built in self-test mode Built in timer .02 to .18 sec.
...morefrequency relays
Operations of the relay can be tested by means of a test, button which energies the output relays & LED’s after set time delay with the channels set to underover frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated, The relays are suitable for any application in industrial plants & to generators where definite time underover frequency protection is required.
...moreFloat Cum Boost Charger
Right from the starting, we have been growing remarkably owing to our policy of incorporating the latest technology into manufacturing of our product line. Uninterrupted Power supply (UPS) systems, Battery Chargers, Static Relays, and Servo Stabilizers. With our independent and creative R&D capability and customer-oriented and market-driven strategy, we have started offering Software interface, remote monitoring, redundant systems, etc. In short for all these years ARMO has always been ahead in offering latest technology, best quality, highest engineering standards & ultimate reliability in the products manufactured & supplied.
...moreFerroresonant Transformer
This energy storageco-operates in conjunction with mains capacitors to produce self-generated AC flux fields which is indirectly excited from the input winding.This results in instantaneous voltage regulation,no transient,no spikes,sine wave output,noise less operation and high isolation between inputs and outputs.Zero Voltage Potential between Output, neutral and ground.
...moreelectronic inverter
Unreliable Power supply should not damage your costly equipments. ARMO the leaders in power protection bring you India’s most reliable inverter. Get an ARMO Inverter today and say goodbye to power cuts!Sophisticated Constant Voltage current limit (CVCL) charger to avoid over charging is also provided. This also assures full charging within expected time, even when mains supply is very low (170V).This assures full backup.
...moreBe first to Rate