Farmson Solar Water heater 250 Liter
24,000 - 25,500 Per units
500 500 (MOQ)
Off Grid Solar Power Plant
65,000 Per Unit
1 Unit (MOQ)
Best Deals from Water Heaters
Solar Water Heater
12,000 - 100,000 Per LPD
10 LPD (MOQ)
Solar Water Heater
19,000 Per Piece
Solar Water Heater
Get Price Quote
Water Heater
6,073 Per Units
Shop Water Heater/Geysers online in India from top brands on Frikly. Buy Water Heater/Geysers by comparing price, brands, capacity, energy efficiency, and smart features (Touch Control, Digital Display) on Frikly. Offer on bulk purchases, wholesale rate. Upto 60% OFF!
Electric Water Heater
4,000 Per Piece
We make sure that the packing of our products is done using quality materials and advanced machines. Our packaging experts handle the entire task of packaging keeping in mind the requirements of the clients. Our team makes it possible to carry out online transactions, keeping the details confidential. Our payment procedures and the transactions we make are completely transparent and thus, clients can trust on us.Features : ABS body Shock proof Instant hot water supply No maintaince Warranty - 1year
Solar Water Heater
Get Price Quote
We are a popular Supplier of Solar Water Heater. The Heater is the most favorite among customers for its enhanced functionality and unbeatable performance. The packaging is done properly before dispatch. The Water Heater can be obtained from us in bulk or in small quantities as per the needs of the clients. Customers can procure the Heater at pocket friendly rates.
Solar Water Heater
40,000 - 46,000 Per Piece(s)
1 Piece(s) (MOQ)
Electric Geysers
2,400 Per Piece
1 Piece (MOQ)
Gas Geyser
Get Price Quote
Industrial Solar Water Heater
Get Price Quote
SYSTEM OPERATION SOLAR THERMAL: There are two types of solar water heating systems, based on type of circulation; 1. Thermosyphon 2. Forced circulation All domestic and industrial systems upto 4000 LPD (liters per day) @ 60 deg.C,; works on the principle of thermosyphon. Industrial systems beyond 4000 LPD to any capacity will work on forced circulation principle. Thermosyphon system:: The system works on a principle called "THERMOSYPHON" (Natural circulation).Due to density difference between the cold & hot Water, the lighter hot water flows up into the tank and the heavier cold water enters the collector. Solar radiation incident on the collector panels heats the absorber. This heat is transferred to the water contained in the absorber & becomes less dense than the water in the storage tank. Hot water starts rising and settles at the top of the storage tank. Simultaneously cold water descends to the collector absorber tubes, gets heated up and the cycle repeats. The circulation in the system during the heating process is purely due to the difference of density only. There is no other mechanical moving part, hence the system reliability is very high. At the end of the day when radiation is zero (after dark / sun set) the collector will contain heavier cold water and the tank will have lighter hot water. This will ensure that there will be no circulation during night & hence no conduction losses on account of this. The hot water storage tank is well insulated to retain the hot water temperature and to minimize the overnight temperature drop / heat losses. The Sacrificial Anode (Only for SS tank) prevents the tank from galvanic corrosion. For the monsoon / cloudy days the system is-fitted with Electrical back up heater with thermostat. Forced circulation system: In forced circulation systems, two pumps in tandem are used for circulation of water between collector bank & system insulated tank. The pump operation is controlled by OTC (Differential Temperature Controller), which is fitted Inside the Control panel. OTC senses the cold & hot water temperature through two sensors, one fitted at the bottom of the tank to sense cold water temperature & the other fitted at the top of the last collector of the row in the collector bank, to sense the hot water temperature inside the collector The difference in temperature between the two sensor points is the criteria for the operation of the pump that is controlled through DTC. This temperature difference can be set between 0 to 10 deg, C. Solar radiation falling on the collector heats up the water inside the absorber. The temperature of water starts gradually increasing compared to the water temperature inside the tank. When this temperature difference between the sensor points reaches the preset temperature difference in DTC, the pump is switched "ON". This will result in entry of cold-water form the system-insulated tank into the collector bank & discharge of hot water from the collector bank to the system insulated tank. The process of switching ON & QFF of the pump & circulation of water continues till the end of the day. By the end of the day, the entire quantity of water in the tank reaches the system-designed temperature, provided the radiation level is at minimum of 800 watts per sq.mtr. The process of switching ON & QFF of the pump & circulation of water continues till the end of the day. By the end of the day, the entire quantity of water in the tank reaches the system-designed temperature, provided the radiation level is at minimum of 800 watts per sq.mtr.
Solar Water Heater
15,000 Per Piece
1 Piece (MOQ)
Evacuated Tube Solar Water Heater Hot Max
Get Price Quote
Avail the Evacuated Tube Solar Water Heater HOT MAX model that is offered to the clients at affordable rates. The Evacuated Tube Solar Water Heater HOT MAX is high on demand in the market for high performance and durability. Standard Collector Size Flat Plate Collector (9 fin)Width - 1150mm (East -West)Length -2080mm (South -North)Evacuated Tube-Glass Tube, Collector (for 500 ltr)Width - 3100mm (East -West)Length - 2200mm (South-North) Weight of the Collector with water & legs Flat Plate collector - 46 Kgs.Evacuated Tube-Glass Tube, Collector (for 500 ltr) - 310 Kgs In domestic systems to heat water @ 60 deg C per day One Flat Plate collector is used per 100 lit.For 100 LPD system - 1 collectorFor 200 LPD system - 2 collectorsOne Evacuated Tube Collector assemlyFor 100 LPD system - 15 nos evacuated glass tubesFor 200 LPD system - 30 nos evacuated glass tubes In Industrial systems (above 500 LPD) to heat water @ 60 deg C per day One Flat Plate collector is used per 125 lit.For 1000 LPD system – 8 collectors,For 2000 LPD system – 16 collectorsOne Evacuated Tube Collector (assembly of 70 tubes each) is used per 500 ltr.For 1000 LPD system – 2 manifolds collectors,For 2000 LPD system – 4 manifolds collectors The systems can be designed to heat water at temperature up to 80deg. C Area required for installation per 1000 LPD System @ 60 deg. C is For Flat Plate collector systems - @ 32 sq.mFor Evacuated Tube Collector systems - @ 24 sq.m. Systems are available for pressures >1.0 bar
Domestic Solar Water Heater
15,900 Per Piece
We at eminent organization, is engaged in offering Domestic Solar Water Heater. The offered water heaters are developed using superior-grade components that are checked on various parameters. Hi-Tech Solar technicians can Manufacture & Install Solar Water Heater as per Roof top constraints. We develop Standard & Proven benchmark for Solar Thermal Technology in Domestic area.Model : Premium -Specialized GI Heavy Tank For Hard water: Heavy Water Storage tank made from finest Hot Dip Galvanized mild & low carbon steel. Tank is coated with Ultra heat resistance modified food grade coating protects against corrosion and ensures very long life. Outer cover is 7 tank processed PEF Metallic powder coating, which is highest UV resistance and protect against corrosion and ensure longer, service free life.-Hi-efficient Three Layer Conductive Evacuated Glass Tube Collectors: Hi-efficient three layer conductive Evacuated glass tube collectors are coated with three layers Cu/SS/Al – N with high power MFMS coating ensures highest heat absorption. Hi-Tech Solar comes with more conductive glass tubes which provide more and more hot water.-Stand: Specially designed super solid stand made of GI using welding less technology. In house 7 tank process and PEF Metallic powder coating which is highest UV resistance and protect against corrosion and ensures longer life.-Insulation: Hot water storage tank is insulated by automatic machine injected high pressure and high density 50mm thick superior quality PUF which keeps water hot for longer time.:Available Capacities-100 LPD150 LPD 200 LPD250 LPD 300 LPD500 LPD 1000 LPD-Silent Features: . Tank Suitable For Hard Water • Best Performance in Cloudy Season. Easy installation• Longer service life • High performance• Very less Payback Period • Wear and tear resistance • Robust construction
Powermax Solar Water Heater
Get Price Quote
Electric Water Geyser
4,599 Per Piece
2 Piece (MOQ)
Split solar heating system
14,000 Per Set
Solar Water Heater
Get Price Quote
20 Set(s) (MOQ)
This is solar water heater from which you can get hot absolutely free for long life.Life of this heater will 15-20 years.Maintenance is zero.From this you can save electricity as well as Nature.
Integrated and solar water heater
Get Price Quote