Ultrasonic Level Sensor
10,000 Per Piece
Twilight Switch
Twilight Switch works on Twilight principle which automatically switches the lights ON in the evening upon sensing darkness and switches the lights OFF in the morning after sensing daylight. Hence Lamp is ON only when it is required resulting in considerable saving in electricity cost and optimal electricity consumption. It has a by-pass switch with which lights can be switched ON and OFF manually as may be required. Sensor can be removed from the enclosure and can be placed any suitable place outside enclosure (cable length of sensor can be extended to required length). Sensitivity adjustment is provided inside the unit. Unit works on 220 volts AC and offers potential free relay contact
...moreSlot Sensor
offers Fork Slot Sensor with 10 mm slot width. Units operates on 10 - 30 V DC supply. Sensitivity adjustment pot provided for adjusting the sensitivity of the sensor.
...moreSensor Based Lighting System
Safety Light Curtains
Electronic switches manufacturers safety light curtains for finger and hand safety used on hydraulic and pneumatic machines. These are international standards ce approved products used for safety purposes.
Lighting Type : LED
Color : Yellow
Power Source : Electric
Application : Industrial
...moreSafety Barriers
Safety light curtains for blow moulding machines. Safety light curtains are also called as safety barriers or safety guards which are used for finger and hand safety on machines
...moreRudder Angle Indicator
13,000 Per Units
10 Units (MOQ)
Material : PVC
Country of Origin : Made in India
Pull Cord Switch
5,000 Per Number
programmable digital timer
2,000 Per Piece
Display Type : Digital
Voltage : 230 VAC
production counter display
Event Counter with 4 inch seven segment LED display. Units operates on 220 Volts AC supply and accepts input from various sensors. Reset is available as on terminal strip on back
...morePreset Counter
Manual Reset Mode : When preset count is reached the relay status is changed. Counting stops at the preset value. To start the counting from zero, press switch 'E' on the front paneI. The counter resets to '000000' and starts counting. Here resetting is done manually. 2. Auto Reset Mode: When preset count is reached the relay status is changed. Counter will reset automatically to '000000' after a specific preset time & start counting again. Resetting is automatic. The time for which relay status should remain unchanged is settable 3. Up Down Mode: In Up Counter, counting will start from '000000' and increment by one digit for every input pulse. In Down Counter, counting will start from the PRESET value and decrement by one digit for every input pulse. Down Counting will not count below zero. 4. Relay ON OFF Mode : The status of relay can be selected ON OFF during counting. 5. Division Factor Mode: This mode is to set the division factor. Eg: Suppose division factor = 4. i.e. count will increment after every 4 input pulses. 6. Selection of Speed :This mode is to select slowfast speed
...morePick to Light System
50,000 Per unit
Magnetic Reed Switch
400 Per Piece
Switch Configuration : SPST
Current Rating : 10 A
Usage : Used to control the flow of electricity in a circuit
Output : Switching Transducer
Brand Name : Electronic Switches
...moreMagnetic Float Level Sensor
2,000 Per Piece
Material : Stainless Steel
length counter
Manual Reset Mode : When preset count is reached the relay status is changed. Counting stops at the preset value. To start the counting from zero, press switch 'E' on the front panel. The counter resets to '000000' and starts counting. Here resetting is done manually. 2. Auto Reset Mode: When preset count isreached the relay status is changed. Counter will reset automatically after a specific preset time & counter resets to '000000' & starts counting. Resetting is automatic The time for which relay should remain unchanged is settable. 3. Selection of Counting ONOFF: This is applicable to Auto Reset mode only. This is to select whether counting should be ON or OFF during the output relay ON period. This means counting for next cycle can be started a) Immediately after Preset value is reached or, b) After a time period for which Relay is ON
Power Supply : 230 V AC
...moreinfra red sensors
Electronic Switches (I) P. Ltd; offers Diffuse Scan Sensor in 18 mm dia; Brass housing with 100mm / 300mm range. Units operates on 10 - 30 V DC supply. Sensitivity adjustment is available in the unit to adjust the required range. Range of the sensor is 100 mm or 300mm. It is 4 wire type sensor with output NPN and PNP with NO or NC selectable.
...moreHopper Level Sensors
1,000 Per Piece
Ambient Temperature : -20 to 60 deg C
Fork Sensor
1,000 Per Number
Material : ABS Plastic
Electronic Switches Beam Sensor
1,500 Per Piece
Material : Stainless Steel
Digital Temperature Scanner
20,000 Per Piece
Weight : 5 kg
Capacitive Proximity Sensors
1,000 Per Number
Material : Stainless Steel
Belt Sway Switch
Belt Sway switch is mounted on the walkway side of the conveyor belt, preferably at about every 20-25 meters. These Switches are designed for Man and Machine Safety, to avoid accidents, and for stopping the Machine in case of Emergency. In Belt Conveyors, belt swaying occurs due to uneven loading, misalignment of the idlers & due to worn surfaces. Belt Sway Switches are useful to restrict belt sway within the tolerable limits.
...moresensor controller
sensor switches
SAFETY BEAM BARRIERS
Safety Light Curtains
Safety Beam
Sensors
Be first to Rate