Motor protection relay
Get Price Quote
Our range of Motor Protection Relay is used to identify inefficiency in machines and reduce panel space, wiring & installation time. We provide Motor Protection Relay in desired specifications. The range of Motor Protection Relay provided by us is used in major industrial and commercial areas. The Motor Protection Relay provided by us is rich in features. Features State-of-art micro controller-based designRelay output for cutoff / alarmUser programmable alarm set point, time delay & CT ratioTrue RMS measurementAuto-scrolling facilityPassword protectionBar graph indication for loadAlarm / tripUnder voltage Over voltage Over load Phase sequence reversal Phase failure Ideal For Control panelTest benchDistribution systemsAPFC panelGenerator setsEnergy managementMotor controlProcess control & SCADA
Numerical Distance Protection Relay
Get Price Quote
Being a reliable name, we are focused towards delivering exceptional quality range, along with this, we follow strict guidelines and conduct regular quality examinations to ensure quality. We are equipped with the upgraded machines and technology, thus, we are capable of making stern packaging of products. To keep the product safe from external factors, we make use of finest packaging material. Protection Elements for Comprehensive Numerical Transmission Line Protection Relay; Impedance Function : Single Phase Distance Protection Four Independent Groups Five Independent Zones of Protection Permissive Over reach Trip Transfer (Z1ext.) Independent Polygonal/Mho characteristics for Phase to Phase and Phase to Ground Faults Power swing Detection Load Encroachment Detection Settable Switch On to faults and Auto Recloser VT Fuse Fail Circuit Breaker failure(50BF) Disturbance Recorder 16 Red, Green LED for Indications Relay healthy indication (Green). Relay Design Features : Minimum operating time of 1.5 Cycles (30msec). Large 20x4 LCD display for Parameter and setting display. In built Real Time Clock with non-volatile memory for time stamping. Display of various counters Disturbance Recorder - Up to 1sec of actual waveform of current & voltage along with logical and physical status are captured & saved in built-in memory with date time stamping, for analyzing fault condition & fault location. Online display of CB status and other digital and logical status. Continuous monitoring of module’s internal hardware and alarm generation in case of failure of any critical components. 10 Programmable Digital Output contacts. 8 Optically isolated digital status input for monitoring of status and avoid use of external relay logic. 2 dedicated status input for Trip Circuit Monitoring. 100 nos. of event memory, event such CB close, Trip, digital status change, relay pkp etc. All events are with date and time stamped with up to 1ms accuracy. 10 nos. of Fault data stored with keypad interface and time. Display of Voltage, current, frequency, Reactance, Resistance in terms of secondary value. Control Panel: Control Panel suitable for the testing of Numerical Distance protection relay, Mainly consist of Power Input 230V AC 50 Hz, Built in variable current source 0-20 Amp and Variable Voltage source: 0-250V AC, Time interval meter- stop/ start timer digital, Power ON/ OFF mains switch/ MCB, power ON indication, Control circuit for Current injection and voltage injection. Auxiliary power supply for relay 220 or 110 or 48 or 24 Volts AC or DC. Built in digital Ammeter and Voltmeter. With fault simulating switchs.
Best Deals from Protective Relays
Electronic Protection Relay
Get Price Quote
Motor protection relay
Get Price Quote
MPR is an auxiliary relay and it should be used along with the motor starter only. The effective working of MPR will depend on efficient working of electromagnetic motor starter. Before installing MPR check whether the motor starter is operating perfectly by starting the motor with "START" push button and switching it off by "OFF" push button. If motor does not "START" or "STOP" on respective operations, the starter needs to be serviced. Do not install MPR with faulty motor starter.
pump protection relays
Get Price Quote
Phase Failure [Phase LossSingle Phasing] Phase sequence reversal Voltage Unbalance Under Voltage, Over Voltage Overload protection as per motor characteristics No-loaddry running Motor winding overheating Over-currentShort circuitlocked rotor Earth Fault
Protection Relays
Get Price Quote
The material that we make use for manufacturing the offered lot of products is of fine quality and tested prior to production of the offerings. To provide our buyers with premium products, we make sure only superior grade materials are used for manufacturing them. Features : Multifunction Relay Platform Over current and earth fault relay Under voltage and over voltage relay Self powered relay Circuit breaker manager Range Over Current & Earth Fault Relay Under-Over Voltage & Neutral Display Relay Self Powered Feeder Protection Relay Circuit Breaker Manager (CBM) AEGIS - Multifunction Relay Platform
Digital Protection Relay
Get Price Quote
Digital Protection Relay, analog panel meter, Insulation Tester