vpi transformers
Industrial, Substation & Distribution purpose Manufacturing range Upto 2MVA 22 KV naturally air cooled. A dry type transformer has an iron core, vacuum pressure resin impregnated high voltage windings and low voltage windings . The low voltage winding is constructed with conductors. Dupond nomex insulating material includes an apparatus to secure the windings in place during a vacuum and pressure resin impregnation process. The result is a coil that exhibits high short circuit protection due to the tightly bond conductors comparable to completely resin encased molded transformers at a substantially reduced cost.
...moreVoltage Converter
Voltage converter which is without neutral and earth fault protection.Neutral earthing transformer has zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply.
...moreTransformer
200,000 - 2,000,000 Per No
1 No (MOQ)
A distribution transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. The invention of a practical efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882. If mounted on a utility pole, they are called pole-mount transformers. If the distribution lines are located at ground level or underground, distribution transformers are mounted on concrete pads and locked in steel cases, thus known as pad-mount transformers. Distribution transformers normally have ratings up to 200 kVA, although some national standards can describe units up to 5000 kVA as distribution transformers. Since distribution transformers are energized for 24 hours a day (even when they don't carry any load), reducing iron losses has an important role in their design. As they usually don't operate at full load, they are designed to have maximum efficiency at lower loads. To have a better efficiency, voltage regulation in these transformers should be kept to a minimum. Hence they are designed to have small leakage reactance.
Certification : ISI Certified, ISO 9001:2008 Certified
Color : Grey, Light Green
Speciality : Easy To Install
Brand Name : URJA
...moreStep Up Transformer
Step up transformer is connected to the power source and the other windings are known as secondary windings. There is a core with one winding of wire placed close to one or more windings, which can couple two or more alternating-current circuits together by employing the induction between the windings. If the secondary voltage wire is less than the primary wire, the transformer is called a step down transformer. If the secondary wiring is of higher voltage, the transformer is a step-up transformer, which increases voltage input.
...moreStep down transformer
Step down transformer are very easy and required devices. But the step down transformers continue to change with the latest updated technology as per their designs and materials. Step down transformers are electrical devices that change power via coupling. The primary winding is connected to the power source and the other windings are known as secondary windings. There is a core with one winding of wire placed close to one or more windings, which can couple two or more alternating-current circuits together by employing the induction between the windings. If the secondary voltage wire is less than the primary wire, the transformer is called a step down transformer. If the secondary wiring is of higher voltage, the transformer is a step-up transformer, which increases voltage input.
...moreSpecial Purpose Transformer
150,000 - 1,500,000 Per Piece
1 Piece(s) (MOQ)
neutral earthing transformer is having zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply. Cooling with conventional pressed steel radiators. The range includes up to 33 kv systems and as per the site requirements.
...moreSingle Phase Transformer
Single phase transformer are specified with very specific arrangements to suit the bus-bar arrangement and cooling system. Furnace bus-bars are mostly water cooled. Due to the high secondary currents and resistive losses the furnace layout is such as to limit the bus-bar length.
...moreShunt Reactor
We make sure that the offered lot complies with the stated quality norms, thus check the product quality on several stages. We are reckoned amongst illustrious suppliers of Shunt Reactor supplying to purchasers through assorted markets.
...moreRectifier Transformers
We are supplier and exporter of this product.
rectifier duty transformers
This product is used as set up transformer from generator to line voltage. It has a range up to 10 MVA with the voltage capacity of up to 33 KV. It is s very durable and hassle free to be used by desired clients. It comes with an automatic onoff cooling option. We offer these converter duty transformers at a competitive price.
...morereactor transformers
Application : up to 2 MVAR
Power Transformers
Specifications: 'Tap Changer' options available "Off Circuit Manually Operated" and "On Load Tap Changer" (OLTC) with AVR and RTCC panel Prime quality, low loss, high permeability 'Cold Rolled Grain Oriented' silicon steel for core to achieve low no load losses Electrolytic copper with insulating paper multi covered round wires and strips for both the primary and secondary windings to achieve low load losses ONAN /ONAF cooling with conventional pressed steel radiators Terminal arrangement is done for primary and secondary as per site requirements in these power Power Transformers and single phase Power Transformers Low viscosity power distribution transformer oil with in numerous superior grades for specific usage
Voltage : up to 132 KV
Power : 3.15 to 20 MVA
Phase : Single Phase, Three Phase
Usage : Power / Distribution / Furnace etc.
...morePower Distribution Transformers
Power distribution transformers are comprised of a plurality of conductor strands spirally wound for a plurality of coil layers. The low and high voltage winding sections are laterally spaced with the low voltage windings disposed in side-by-side positions and adjacent to the high voltage windings. The high voltage windings have a smaller turn height than the low voltage windings and have conductor strands of smaller gauge than the pancake coils of the low voltage windings.
...morel t transformers
L T transformers the dielectric insulating fluid in the transformer tank is completely sealed and is in zero contact to the atmosphere. The design avoids air in the transformer tank thereby avoiding sludging and oxidation of the dielectric fluid.
...moreIndustrial Transformer
Industrial transformer , they are called pole-mount transformers. If the distribution lines are located at ground level or underground, distribution transformers are mounted on concrete pads and locked in steel cases, thus known as pad-mount transformers.
...moreHermetically Sealed Transformer
Hermetically sealed transformer is a transformer design which has no conservator. Here the dielectric insulating fluid in the transformer tank is completely sealed and is in zero contact to the atmosphere. The design avoids air in the transformer tank thereby avoiding sludging and oxidation of the dielectric fluid. Hermetically sealed transformers are totally maintenance free and are particularly suited for use in exposed outdoor environments such as moisture, salt or dust laden atmospheres. They are used extensively in chemical plants, oil and gas terminals where poor accessibility makes regular maintenance impracticable. Transformers immersed in synthetic coolants are suitable for use indoors with adequate ventilation or near to the load center where oil would not be considered environmentally acceptable. Normally these type of transformers are accommodated by devices that measure heat related volume variations. Gas cushion is used to compensate the volume variation due to heat. Normally the gas is nitrogen. This gas is thermally uncoupled from the dielectric liquid.
...moreHermatically Sealed Transformers
URJA is managed by a group of technocrats having vast and varied experience in transformer design, development, production, quality control and servicing. Its modern manufacturing plant with state-of-the-art manufacturing and testing facilities as per IS, IEC & ANSI standards, accredited to ISO-9001:2008, 14001:2004, 18001:2007 by Moody International, believing in producing excellent quality products to its customers.URJA’s strength lay in good marketing network, stable customer relationship and commitment to the highest levels of service and excellence.Renowned for its flexibility in repair of many different types and brands of transformers URJA has completed a multitude of contract for repairs. URJA’s “e-con.tek Transformers” having Low Loss and High efficiency designs incorporates more copper, resulting into “Less power consumption.”Hermetically sealed transformer is a transformer design which has no conservator. Here the dielectric insulating fluid in the transformer tank is completely sealed and is in zero contact to the atmosphere. The design avoids air in the transformer tank thereby avoiding sludging and oxidation of the dielectric fluid.Hermetically sealed transformers are totally maintenance free and are particularly suited for use in exposed outdoor environments such as moisture, salt or dust laden atmospheres. They are used extensively in chemical plants, oil and gas terminals where poor accessibility makes regular maintenance impracticable. Transformers immersed in synthetic coolants are suitable for use indoors with adequate ventilation or near to the load center where oil would not be considered environmentally acceptable.Normally these type of transformers are accommodated by devices that measure heat related volume variations. Gas cushion is used to compensate the volume variation due to heat. Normally the gas is nitrogen. This gas is thermally uncoupled from the dielectric liquid.
...moreFurnace Transformers
Specifications: "Off Circuit Manually Operated" and "On Load Tap Changer" (OLTC) with AVR and RTCC panel OFWF cooling with ONAN cooling optional ONAN cooling with conventional pressed steel radiators Requisite series reactors for arc furnace transformers to reduce the short circuit stresses generated in transformer during the furnace operation Designed to withstand the harmonics generated due to furnace operation 'Tap Changer' options available in these furnace transformers, arc furnace transformers and electric arc furnace transformers.
Phase : Single Phase
Capacity : 10 MVA
...moreFurnace Transformer
One piece (MOQ)
We are offering furnace transformer. we offer furnace transformers and arc furnace transformers for arc furnace/ submerged arc furnace/ induction furnace applications with capacity of 10 mva and primary voltage up to 33 kv class. The secondary voltages of these arc transformers suit furnace specifications with 6 and 12 pulse operations. specifications: •"off circuit manually operated" and "on load tap changer" (oltc) with avr and rtcc panel •ofwf cooling with onan cooling optional •onan cooling with conventional pressed steel radiators •requisite series reactors for arc furnace transformers to reduce the short circuit stresses generated in transformer during the furnace operation •designed to withstand the harmonics generated due to furnace operation •'tap changer' options available in these furnace transformers, arc furnace transformers and electric arc furnace transformers.
...moreearthing transmitters
Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection. Neutral earthing transformer has zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply. ONAN /ONAF cooling with conventional pressed steel radiators. The range includes up to 33 KV systems and as per the site requirements. A Earthing ( zigzag) transformer is a special purpose transformer with a zigzag or 'interconnected star' winding connection, such that each output is the vector sum of two phases offset by 120°.
...moreEarthing Transformers
We are supplier and exporter of this product.
Phase : Single Phase
Brand Name : Urja Techniques
Earthing Transformer
One piece (MOQ)
We are offering earthing transformer. earthing up to 10 mva – 33 kv - earthing transformers are used to create a neutral point in a three-phase system, which provides possibility for neutral earthing. The earthing can be through an arc-suppression reactor, a neutral earthing reactor or resistor or directly in these earth transformers. Earthing transformers are usually oil immersed and may be installed outdoor. In cases where a separate reactor is connected between the earth transformer neutral and earth, the reactor and the transformer can be incorporated in the same tank. neutral earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection. neutral earthing transformer is having zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply in these earthing transformers. onan /onaf cooling with conventional pressed steel radiators. The range includes up to 33 kv systems and as per the site requirements.
...moreDry Transformers - Vpi
One piece (MOQ)
We are offering dry transformers - vpi. dry type transformers are suitable for indoor installations in explosive atmospheric areas and populated locations such as malls, multiplex etc. These dry type transformers have f or h insulation class with or without enclosure as per the site requirement. dupont nomex insulating material is used to secure the windings in place during vacuum and pressure impregnation process with superior class of resin to suit highly humid / dusty atmosphere & free from fire hazard. The result is a coil that exhibits high short circuit protection due to the tightly bond conductors comparable to completely resin encased molded transformers at a substantially reduced cost. dry transformers are very compact in sizes and hence suitable for basement installations in high rise buildings etc. Dry transformers are available with low losses giving savings over long service periods. Periodical vacuum cleaning of winding surface is the only maintenance. The capacity range of these iron core transformer is up to 2000 kva with primary voltage up to 11 kv class & secondary voltage between 433 to 6600 volts. we offer wide range of dry type transformers, dry transformers, dry type distribution transformers, dry distribution transformers, dry type electrical transformers, iron core dry type transformer, industrial dry type transformers, industrial iron core dry type transformer, dry type transformer, iron core dry type transformers, iron core dry type transformer, compact dry type transformers.
...moreDry Transformers
We are supplier and exporter of this product.
Phase : Single Phase
Type : Indoor/Outdoor-Oil/Dry Type
Voltage : 433 to 6600 Volts
Brand Name : Urja Techniques
...moreOpening Hours