Automatic Power Factor Panel
Get Price Quote
We Bajaj Steel Industries Limited, Nagpur take this opportunity to introduce ourselves as a company that has achieved global proportions in Cotton Ginning and Pressing technology
Main Distribution Board Panel
Get Price Quote
1 Piece (MOQ)
Best Deals from Power Panels
Gas Distribution & Selector Panel
2,000 - 3,500 Per Number
1 Piece (MOQ)
LABIN GDP to provide for an equal distribution of each of GC gases like Air, N2, H2, He, Ar. & others. Especially uses for more than one GC Instruments.LABIN Provide 3 types of Model as per below. Model: T, TG, TGR Model: T (Only Shut-Off Valve) Model: TG (Only Shut-Off Valve & Pressure gauge) Model: TGR (Shut-Off Valve, Pressure gauge & Regulator) Gas Selector PanelLABIN Make Gas Selector Panel for changing the outlet carrier gas flow either Nitrogen or Helium gas without halting your analysis.
automatic power factor controller panel
Get Price Quote
1 Piece (MOQ)
Solar Power Panel
29 - 31 Per Watt
12 No (MOQ)
Electric Power Distribution Panels 1
Get Price Quote
With its client oriented service for past several years, our company has gained a renowned name and fame in the market for the manufacture and supply of a wide array of Electric Power Distribution Panels. These Electric Power Distribution Panels are one of the most required and necessary equipment for industrial purposes where there are provisions of complex electrical circuits and costly machinery. Electric Power Distribution Panels are generally connected to the main power source and are meant to control even and regulated power dissipation in the circuits. Electric Power Distribution Panels are available at a very convenient and exiting range of prices at our company.Features Cost effective Reliable work performance Smooth and hassle free functioning Equipped with easy controlling switches and regulators Provided with LED indicators and meters Robust and durable construction
Main LT Distribution Panel
20,000 Per Unit
1 Unit (MOQ)
Real Time Power Factor Control Panel
Get Price Quote
We are engaged in offering technically advanced Real Time Power Factor Control Panel in the market. Real Time Power Factor Control Panel is modern power factor correction system having ability of correcting power factor in real time. Our Real Time Power Factor Control Panel is incorporated with high end measuring and complete harmonics free pollution and isolation circuits that are microcomputer based . We have equipped quickly responsive and advanced computing software in these panels. Our Real Time Power Factor Control is designed the reactive power on real time basis for extremely rapid acquisitions of power factor. Connecting and Disconnecting of capacitor to and from network occurs a zero crossing, which smooth the connections of the circuit . This smooth connection avoids transient effects such as waveform distortions, generating of switching spikes etc. Highlights : Longer service Incorporated with advanced technology Low operating cost Low maintenance Details : Our thyristor switching modules are built with state of the art switching circuits. The switching circuit continuously monitors voltage across thyristor and allows the thyristor to fire only & only if the voltage across the thyristor is zero. Thus the current through the thyristor always starts as if a normal load was switched on, and all the transients & switching pulses associated with other switching systems are totally absent. Because of this we do not use any di/dt reactors. Since the switching is independent of the remnant charge on the capacitor, we do not need any fast discharge resistors or reactors. Since switching in transients & pulses are totally absent, the capacitor life is enhanced several times. The entire system is saved from capacitor switching transients. When harmonics are present, the conventional formula PF=Cos Ǿ is not valid. In such cases PF= Cos Ǿ X Distortion Factor (DF depends on extent of harmonic pollution and is less than 1. Therefore we do not use Cos Ǿ sensing relays. Instead we use KVAR controller. Technical Specification : Operating Voltage For 415V line to line configuration: 300 V~ to 500V~ For 240 V Phase to neutral configuration: 170V~ to 300V~ For 120V Line to Line configuration: 79V~ to 132V~ Current Input: 1A or 5A Capacitor Voltage: 1A or 5A 12V DC/20mA Solid state Output(Open Emitter) or Thyristor Switch Commands. Rating from : 100- 1200 KVAR Standard steps: 6 / 12.5/ 25 / 50 / 75 /100 KVAR System included De-tuned iron core that de-tuned the network to prevent the resonance and absorb the harmonics. Incomer- MCCB/ ACB Capacitor- 450V / 525 V Over temperature protection. Salient Features : The system is maintenance free because it does not use contactors for switching the capacitors. Enhance the capacity of distribution transformer, switchgear and HT cable. Power Factor will maintain almost near to unity so guaranteed P.F. bonus of 4 % to 5 % every month. Capacitors life is enhance minimum 3 to 4 times. Due to electronics switching & rectors available in the system. The reactors will filter the harmonics & prevents the possibility of resonance by shifting resonance frequency below 5th harmonics.
Power Distribution Panel
5,000 - 2,000,000 Per Piece
1 Piece (MOQ)
Distribution Control Panel
Get Price Quote
Power Distribution Panel
Get Price Quote
Our Power Distribution Panel can serve a wide spectrum of applications like power-distribution, control, ground-fault protection and monitoring. Apart from this, Power Distribution Panel also serves as alarm panel for freeze protection, broad temperature-maintenance and heat-tracing applications. These Power Distribution Panels are integrated with ground-fault circuit breakers in an enclosure having assembled circuit-breaker panel board with or without alarms contacts. Furthermore, equipped with the group control package, Power Distribution Panels have the capability of automating operation in conjunction with an ambient-sensing thermostat, individual electronic or duty cycle controller.
Lighting Distribution Panel
Get Price Quote
1 Piece (MOQ)
A distribution board is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.
Distribution Panel
Get Price Quote
10 piece (MOQ)
We provide high quality Distribution Panel that saves a lot of energy of the unit, and hence widely in demand. Design of our Distribution Panel is exclusively developed by talented engineers who have vast industrial experience. Our Distribution Panel needs low maintenance and can withstand extreme wear and tear. We are engaged in offering wide range of Electrical Panels to the customers at industry leading prices. The Electrical Panels offered by us are manufactured as per the varied requirements of the customers, that has further helped us in gaining their trust and confidence. Our team of experts make these products using latest technology and sophisticated equipment. Specification : 415v 3phase Generator and power Supply Attributes Long life High performance Robust construction Energy efficient Size Available : 300X1800X1800mm Applications : Light and power system Material Used : L&T Schneider C&S ABB
Three Phase Automatic Power Control Panel
130,000 Per Nos
1 Nos (MOQ)
Automatic Power Factor Control Panel
50,000 - 70,000 Per Piece
1 Piece (MOQ)
Automatic Power Factor Control Panel
55,090 Per Piece
1 Piece (MOQ)
Solar Power Panel
Get Price Quote
A solar thermal power plant utilizes solar thermal energy as a primary energy source by using solar heat absorbers. Depending on the plant's specific design, solar thermal power plants are generally more efficient than photovoltaic systems and usually require lower specific capital investment. Solar thermal power plants are suitable for use only in very sunny regions.One of the popular technology used for heat and power generation is Parabolic trough technology : In this the sunlight is collected by parabolic-trough mirrors and concentrated in a collector tube that contains a heat transfer fluid (synthetic oil) which is heated at a temperature of around 400°C by the solar energy. This oil is hot enough to generate steam via a heat exchanger; the steam is then used to drive the power plant turbines. We also manufacture all types of panels used in Solar Power plants
Automatic Power Factor Control Panel
Get Price Quote
1 Piece (MOQ)
LT Distribution Panel
Get Price Quote
Power Distribution Panel
Get Price Quote
1 Piece (MOQ)
LT Distribution Panel
45,000 Per Piece
1 Piece (MOQ)
Power Control Panel
Get Price Quote
Power Distribution Panel
25,000 - 500,000 Per Piece
01 Piece (MOQ)
Automatic Power Factor Correction Panel
28,000 - 150,000 Per Unit
1 Box (MOQ)
Power Control Center Panel
Get Price Quote
1 Piece (MOQ)
Description PCC ( Power Control Center ) Panels We manufacture and supply Power Control Centers (PCC) Panels, which are used for diverse industrial applications. These are used to supervise and control the voltage and reactive power of the power system. These panels are made of quality raw material and are extremely sturdy in construction.
Automatic Power Factor Panel
Get Price Quote
We have most up-to-date machines and cutting-edge technologies to make sure that the products are packed accurately. This assures that the products are safe from the external damaging factors. We are backed with advanced logistics services owing to which we are flexible in delivering the product range of time and with utmost safety.
Automatic Power Factor Panel
Get Price Quote
Power factor is the ratio between the KW and the KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively the current is being converted into useful work output and more particularly is a good indicator of the effect of the load current on the efficiency of the supply system. All current flow causes losses both in the supply and distribution system. A load with a power factor of 1.0 results in the most efficient loading of the supply. A load with a power factor of, say, 0.8, results in much higher losses in the supply system and a higher bill for the consumer. A comparatively small improvement in power factor can bring about a significant reduction in losses since losses are proportional to the square of the current.When the power factor is less than one the ‘missing’ power is known as reactive power which unfortunately is necessary to provide a magnetizing field required by motors and other inductive loads to perform their desired functions. Reactive power can also be interpreted as wattles, magnetizing or wasted power and it represents an extra burden on the electricity supply system and on the consumer’s bill. Specifications : A poor power factor is usually the result of a significant phase difference between the voltage and current at the load terminals, or it can be due to a high harmonic content or a distorted current waveform. A poor power factor is generally the result of an inductive load such as an induction motor, a power transformer, and ballast in a luminary, a welding set or an induction furnace. A distorted current waveform can be the result of a rectifier, an inverter, a variable speed drive, a switched mode power supply, discharge lighting or other electronic loads. A poor power factor due to inductive loads can be improved by the addition of power factor correction equipment, but a poor power factor due to a distorted current waveform requires a change in equipment Design or the addition of harmonic filters. Some inverters are quoted as having a power factor of better than 0.95 when, in reality, the true power factor is between 0.5 and 0.75. The figure of 0.95 is based on the cosine of the angle between the voltage and current but does not take into account that the current waveform is discontinuous and therefore contributes to increased losses. An inductive load requires a magnetic field to operate and in creating such a magnetic field causes the current to be out of phase with the voltage (the current lags the voltage). Power factor correction is the process of compensating for the lagging current by creating a leading current by connecting capacitors to the supply. P.F (Cos Ǿ)= K.W / KVA Or P.F (Cos Ǿ)= True Power / Apparent Power. KW is Working Power (also called Actual Power or Active Power or Real Power). It is the power that actually powers the equipment and performs useful work. KVAR is Reactive Power. It is the power that magnetic equipment (transformer, motor and relay)needs to produce the magnetizing flux. KVA is Apparent Power. It is the “vectorial summation” of KVAR and KW.
LT Distribution Panel
Get Price Quote
10 Piece (MOQ)
We AUMTON INDIA fast growing in electrical panel manufacturing industry, we manufacturing and supplying all type of LT distribution panel, APFC, AMF, MCC, And PLC, VFD panels. Our Product we follow quality product for long life and we using as per customer suggest major brand switchgears. We also provide customize industrial automation panels as per customer requirements.
Power Control Centre Panel
Get Price Quote
We are offering the best range of Power Control Centre Panel to our valued buyers. Located in New Delhi, we are a renowned Manufacturer, Exporter and Supplier of Power Control Centre Panel. Available with power stabs, we are capable of customizing the Control Panel to meet the industrial requirement of the customer. Buyers can get their hands on Power Control Centre Panel at the best prices.
lighting distribution board panel
Get Price Quote
1 Piece (MOQ)