Scroll
Get Price Quote
1 Piece (MOQ)
WAE Energy Saving Remote Chiller
Get Price Quote
1 Piece (MOQ)
Remote water chillers convert standard drinking fountains into a water cooler.Fully enclosed for safe mounting anywhere. Ideal for permanently wired applications.
Best Deals from Commercial Air Conditioner
Multiple Compressor Air Cooled Scroll Chiller
500,000 - 1,000,000 Per
1 Piece (MOQ)
Collar Damper
Get Price Quote
air cooled scroll chiller
200,000 Per Piece
ALUMINIUM GRILLS, DIFFUSERS, DAMPER
Get Price Quote
airconditioning plant accessories grill, diffusers, dampers etc. .
commercial chillers
Get Price Quote
Specialized in offering quality products to our clients, our organization is presenting a wide assortment of Commercial Chillers. Relying on its quality characteristics, these chillers are used in different industries including commercial, industrial, military and laboratory applications. These are packed with advanced control circuitry along with compressor saver technology that makes it highly recommended among others. The innovative design of these chillers allows quick cooling without making any noise. As the available range does not require any kind of electrical mechanism, thus enhances the life of a compressor. This cooling system act as refrigeration a system that cools down the process fluid and dehumidifies air in both commercial and industrial facilities.
HVAC System - Heating, Ventilating, and Air Conditioning
Get Price Quote
1) Cleanroom Architecture – Materials of construction and finishes are important in establishing cleanliness levels and minimizing the internal generation of contaminants from the surfaces. 2) Clean Room HVAC System – The integrity of the cleanroom environment is created by the pressure differential compared with adjacent areas through heating, ventilation and air-conditioning system. The HVAC system requirements include: Supplying airflow in sufficient volume and cleanliness to support the cleanliness rating of the room. Introducing air in a manner to prevent stagnant areas where particles could accumulate. Filtering the outside and re-circulated air across high efficiency particulate air (HEPA) filters. Conditioning the air to meet the cleanroom temperature and humidity requirements. Ensuring enough conditioned makeup air to maintain the specified positive pressurization. 3) Interaction Technology – Interaction technology includes two elements: (1) the movement of materials into the area and the movement of people and (2) maintenance and cleaning. Administrative instructions, procedures and actions are necessary to be made about the logistics, operation strategies, maintenance and cleaning. 4) Monitoring systems – Monitoring systems include a means of indicating that the cleanroom is functioning properly. The variables monitored are the pressure differential between the outside environment and the cleanroom, temperature, humidity and, in some cases, noise and vibrations. Control data should be recorded on a routine basis. HVAC SYSTEM DESIGN FOR CLEAN FACILITY HVAC systems in cleanrooms are substantially different from their counterparts in commercial buildings in terms of equipment design, system requirements, reliability, size and scale. A cleanroom differs from a normal comfort air conditioned space, in the following ways. Increased Air Supply: Whereas comfort air conditioning would require about 2-10 air changes/hr, a typical cleanroom would typically require 20 – 60 air changes and could be as high as 600 for absolute cleanliness. The use of high efficiency filters: The use of high efficiency particulate air (HEPA) filters having filtration efficiency of 99.97% down to 0.3 microns is another distinguishing feature of cleanrooms. The HEPA filters for stringent cleanrooms are normally located at the terminal end and in most cases provide 100% ceiling coverage. Room pressurization: The cleanroom is positively pressurized (to 0.05 in-wc) with respect to the adjacent areas. This is done by supplying more air and extracting less air from the room than is supplied to it. CHEMPHARM ENGINEERED SYSTEM INCLUDES ENERGY EFFICIENT KEY COMPONENT AS- Reciprocating/Screw/Scroll type Chiller Unit with VFD Controller. DX Unit/VRF unit Built-in PLC System for Low tonnage requirement. Hot Water Generator with Built-in PLC for Winter Heat/ Monsoon Reheat requirement. CHW/CDW pumps with VFD Drive to control the speed as per demand. Air Handler with centrifugal plug fan or DIDW Backward Curve fan has been select for controlled flow air based on the Flow & Static Pressure requirement of Varies application. Dehumidifier/ Humidifier System to Maintain the Inside RH/Tem all-round the Year. Heat recovery System to enhance the power saving. Thermal Filtration System with HEPA (H-13) or ULPA (H-14) filter where ever required as per Clean Room Classification. Factory built Square, Round or Oval Ducts having slip on or TDF type flanges based on the line / system pressure and requirements – All ducts are built as per ASHRAE 2012 Duct construction Standard. Thermal Insulation are chosen based on Application & ambient condition but fibre free and as per ASTM standards – Standard specification / material are –Nitrile Rubber, XLPE , PU BASED , ROCK WOOL , MINERAL WOOL , GLASS etc
Segregated Bus Duct
Get Price Quote
Looking for premium quality Segregated Bus Ducts in India? Then you are at right place. Bamaa Group is a very popular name in the electrical goods and accessories market and we specialize in production and supply of advanced Segregated Bus Ducts. Designed by our expert team, these Segregated Bus Ducts have all stage conductors in the same cabinet or alternatively can also be provided with each conductor alienated by a grounded enclosure from near phases. The unique designs of Bamaa’s Segregated Bus ducts make them stand out and apart from other similar products on offer in the market. Furthermore, we also ensure that each Segregated Bus Duct produced by us meets internationally accepted quality and performance norms. In order to do so, we subject our Electrical Segregated Bus Duct to series of quality checks on different factors such as thermal effects, heating effects, voltage drop, electro dynamic force and so on. Premium quality and unique design of our product has helped us earn Kenya,Nigeria,Qatar,Zealand,Taiwan among the topmost Segregated Bus Ducts Manufacturers, suppliers and Exporters from India. FEATURES Low maintenance Highly power efficient Excellent durability Pocket friendly prices Ampacity studies Made from industrial grade materials Reliable operational efficiency WIDELY USED IN Electrical wiring Multiphase power plugs & sockets Building wiring Electric power transmission Industrial power plugs & sockets
Laboratory Water Chiller
195,000 Per Piece
1 Piece (MOQ)
Water And Syrup Chiller Machine
Get Price Quote
Suitable for bringing down the temperature of water / syrup below 4 c. This facilitates mixing and absorption of CO with water / syrup. It is available in two 2 models: Batch Type Incorporates insulated stainless steel holding tank connected to compressor. Water / syrup is by means of chilled gas running inside copper tubes in the tank. Available from 200 to 10,000 LPH capacities. Continuous Type This incorporates online chiller connected with PHE. The online chiller chills the glycol which in turn chills water / syrup in the PHE. Capacity: 500 - 5,000 ltr/hr.
White Fan Coil Units
Get Price Quote
Clean Room HEPA Fan Filter
Get Price Quote
HEPA Fan Filters :Designed to maximize contaminant reduction and operating efficiency, and minimize sound output, HEPA filters are a critical feature in larger cleanrooms with semi to full ceiling fan coverage. The type of HEPA filter to use is determined by the design approach of the cleanroom. Motorized HEPA filters are typically utilized in negative pressure plenum designs for dual-ducted designs. Non-motorized, ducted HEPA filters are utilized with a central air handler providing temperature and humidity control.HEPA Fan Filter : Air velocity of 90 fpm Air flow of 650 cfm 99.99% operating efficiency Removes micron particles 0.3 and larger RSR HEPA Fan Filter : Room Side Replaceable HEPA FilterULPA Fan Filter : Air velocity of 90 fpm Air flow of 650 cfm 99.999% operating efficiency Removes micron particles 0.12 and larger
Damper Actuator
Get Price Quote
SDTORK Flame Proof electric actuators are design to provide reliable and efficient operation of 90 degree quarter turn valves, dampers, etc.Actuator torques ranges from 80Nm to 3,000Nm, currently ten models are available: Compact type actuator, SD-HQ006, is also available separately.
air cooled scroll chiller
Get Price Quote
MAC / McSMART: 2.0 ~ 45 TR Model: Scroll Chiller SALIENT FEATURES Available with heat pump application Better part load efficiency with multiple compressor Brazed Plate Evaporator Ozone friendly refrigerant Compact modular design
Collar Damper
Get Price Quote
Collar Damper
Water Cooled Chiller
Get Price Quote
Water Cooled Chiller, Cooling Towers, Air Cooled Heat Exchanger
Industrial Chiller
90,000 Per Piece
Long Distance Piping Packaged AC
Get Price Quote
Long Distance Piping Packaged AC, distance education, Distance Estimator
ducted split air conditioners
Get Price Quote
ducted split air conditioners, Packaged Air Conditioner