Current Transformers Dealers in Sector 10, Noida

(8 products available)
  • Current Transformer

    Current Transformer

    Get Price Quote

    We are offering current transformer. Current transformers are used between ammeter and current carrying wire to measure high currents.

    more..
  • Insulated Current Transformer

    Insulated Current Transformer

    500 Per Piece

    • Features: Minimum maintenance, Superior functionality, Robust design
    more..
  • Best Deals from Current Transformers

  • CURRENT TRANSFORMER / SHUNTS

    CURRENT TRANSFORMER / SHUNTS

    Get Price Quote

    VAISHNO CFG" Make low voltage current transformers as per IS standard of IEC 60044-1(BSEN 60044-1). CT's convert an alternating current usually high into a proportional lower one, depending on their use. The design of the Current transformer requires the inclusion of a core and winding which will when connected to its rated burden."VAISHNO CFG" Make CT's are broadly classified into the three groups as per their requirement as under:   Current Transformer: An instrument transformer in which the secondary current, in normal condition is use, subsequently proportional to the primary current and differs in phase it by an angle which is approximately zero for an appropriate directions of correction. Measuring Transformer: A current transformer intended to supply indicating instruments integrated meter, relay and similar apparatus. Protective current transformer: A current transformer intended to supply protective supply. Technical Specification Connection: Two connections on each side. M4 screws with self lifting clamp strap assembly. Insulation Class: E (120*C Max.). Operating frequency: 50Hz. Rated Burden: 1, 1.25, 1.5, 2.5, 3.75, 5, 7.5, 10, 12.5, 15, 20, 30, 45, 60, 100VA. Ambient Temperature: -20*C to +45*C. Thermal short circuit current: 40XIn for wound type CT and 60XIn for bus bar type CT. Instrument security factor: 2.5, 5, 10. Accuracy Class: 0.1, 0.2, 0.5 and 1.0.   DC SHUNTS   "VAISHNO CFG" Make DC Shunts are available for current ratings from 5A to 15000A with mV drops of 50-150mV. DC shunts are manufactured with Stringent Quality Control confirming to IS: 1248. Shunts consist of manganin rods/wire/strips soldered or silver brazed to Brass/Copper Blocks. The Shunts are artificially aged after manufacturing, and then tested on full load.    Technical Specification   Accuracy Class: 1 or 0.5. Over Load: Shunts are capable of withstanding temperatures up to 120*C without any permanent alteration in physical or electrical properties. Over loads and faults which results in temperature of this magnitude can be safety handled. Temperature Coefficient: 0.002% per degree centigrade, above ambient temperature in still air, with free ventilation, temperature not exceeding 120*C at the centre and 90*C at the ends. Insulation: Shunts are supplied un-insulated and protection against contact should be installed where applicable. Over Loads (Brass Ended): Continuous 1.2X Rated Current, 5seconds 4X Rated Current up to 30Seconds.5Seconds: 10X Rated Current up to 5Seconds Ambient Temperatures- Calibration- 20*C Working Range-20*C+60*C.   Application   Shunts are used for measuring current in DC Applications by connecting them to moving coil panel meters, Digital meters or other measuring device. Shunts can also be used in control devices such as power supplies and battery chargers or for load protection.

    more..
  • Resin Cast Current Transformers

    Resin Cast Current Transformers

    Get Price Quote

    • Brand Name: KVA Power Equipments LLP
    • Phase: Power Transmission Equipments
    • Model Number: KVA Power - Resin cast Current Transformer
    • Place of Origin: Noida
    • Application: Metering/ Protection

    Epoxy Resin Cast Current Transformer (CT) Resin cast current transformers are available for metering and protection application. These current Transformers are mainly fabricated according to clientÃ�¢Ã¯Â¿Ã‚½ÃƒÃ‚¯Ã‚¿Ã‚½s specification. CT coils are encapsulated in cast resin (Polyester Epoxy). Secondary terminals are provided with either screws or studs. Terminal cover & CT mounting clamps are made available on request. Resin Cast Transformers are dry type transformers the active part of which is completely embedded in quartz loaded Epoxy Resin by using vacuum molding technique. After molding the resin is hardened by polymerization. The main insulation between Primary and Secondary and Earth is obtained by this epoxy resin. These transformers are of compact design with high mechanical and electrical properties. These are non-hygroscopic and hence give very good insulation properties even in given humid conditions.

    more..
  • oil cooled current transformers

    oil cooled current transformers

    Get Price Quote

    • Brand Name: Kapco
    • Place of Origin: India

    The current transformers from Kapco have been deployed by some of the biggest names in the industry. The state-of-art range of current transformers offered by Kapco range from 12KV to 245KV. They utilize oil cooled system, hence are suitable to function outdoors. With both live tank and dead tank options, this range of current transformers are robust and extremely reliable ensuring complete satisfaction of its users.

    more..
  • Current Transformers

    Get Price Quote

    Drum Core Inductors

    more..
  • Current Transformers

    Get Price Quote

    Voltage Transformers, CT PT Combined Metering Unit

    more..
  • Current Transformer

    Get Price Quote

    Current Transformer, Digital Panel Meter, Digital Energy Meter

    more..
Filter by Locality
top