Flame Photometer Dealers in Noida

(2 products available)
  • Digital Flame Photometer

    Digital Flame Photometer

    Get Price Quote

    • Display: 128 X 64 GRAPHICAL LCD DISPLAY
    • Display: 128 X 64 GRAPHICAL LCD DISPLAY
    • RESOLUTION: 0.1PPM/ MEQ
    • REPRODUCIBILITY: ± 2 % OF RANGE ± 1 DIGIT.
    • CURVE FIT ACCURACY: ± 2 % OF RANGE ±1 DIGIT.
    • CALIBRATION: UP TO 5-POINT CALIBRATION WITH CURVE FITTING SOFTWARE .
    • DETECTOR: SILICON PHOTODIODE
    • FILTERS: NA & K INCLUDED. LI & CA AT AN EXTRA COST
    • IGNITION: AUTO IGNITION
    • GAS CONTROL: FULLY ADJUSTABLE
    • ATOMIZER: BLACK BACK ELITE , AXIAL FLOW TYPE
    • POWER SUPPLY: 230 V + 10% AC, 50/60 HZ
    • DIGITAL OUTPUT: RS 232 C PC SOFTWARE
    • DIMENSIONS: 365 X 245 X 220 MM (L X B X H)(APPROX.), WEIGHT : 8 KGS
    more..
    Amaze Instruments
    Noida
    0.0 View Profile
  • Flame Photometer

    Flame Photometer

    Get Price Quote

    • Response Time: <8 sec
    • Suction Jet of Samples: <6ml/min
    • Dimension: 380 x 770 x 570 mm
    • Weight: 18 Kg

    Dual channel, LCD display Pre-selection of flame sizes A flameout protection device K and Na testing at the same time Applications: Flame Photometer is used for analyzing & measuring the content & concentration of K, Na elements Testing cement, glass, ceramics, refractory materials and other construction materials Testing fertilizers and soil Testing products of mining, petroleum, metallurgy, and chemicals Testing pharmaceutical, beverages and other foodMSW testing Various laboratory tests for scientific research, health, education and other fields Technical Specifications: SFP-40: With air-compressor.Measurement Range: K: 0-15, 0-40 μg/ml; Na: 0-40, 0-80 μg/ml SFP-60: With air-compressor. Measurement Range: K: 0-15, 0-40, 0-60 μg/ml; Na: 0-40, 0-80, 0-120 μg/ml SFP-100: With air-compressor, micro-printer or PC software. Measurement Range: K: 0-15, 0-40, 0-60, 0-100 μg/ml; Na: 0-40, 0-80, 0-120, 0-160 μg/ml Linearity Range K: detection limit ≤ 0.004 mmol/lt.; Na: detection limit ≤ 0.008 mmol/lt.Linearity Error K: ≤ 0.005 mmol/lt. (0.0100-0.0800) mmol/lt.; Na: ≤ 0.03 mmol/lt. (0.0500-0.400) mmol/lt.Repeatability: Conduct 7 consecutive independent tests for one standard solution, the relative standarddeviation: ≤ 3%.Stability: Continuous sampling of standard solution, the biggest change in the relative volume in 15 sec: ≤ 3%; Test once every minute, and test 6 times in total, the biggest change in the relative volume: ≤ 15%.

    more..
  • Best Deals from Flame Photometer

Filter by Locality
top