HVAC System Dealers in Noida

(95 products available)
  • Cummins Vibration Dampers

    Cummins Vibration Dampers

    1,000 Per Piece

    10 Piece (MOQ)

    • Material: Galvanized Steel
    • Surface Finishing: Polished
    • Shape: Circular
    • Application: Wind-induced Vibrations
    • Size: Customised
    • Feature: Adjustable, Auto Reverse, Durable, High Quality
    • Country of Origin: India
    • Brand Name: Cummins
    more..
  • Slot Diffuser

    Slot Diffuser

    Get Price Quote

    • Size: Standard
    • Material: Metal
    • Shape: Rectangular, Square
    • Thickness: 5-10 mm
    • Color: Grey
    • Finishing: Polished
    more..
  • Best Deals from HVAC System

  • Pre Air Filter

    Pre Air Filter

    Get Price Quote

    We have marked a distinct and dynamic position in the market by providing a high quality array of Pre Air Filter that is widely used in those areas where low resistance & high dust holding capacity is required. At our well established manufacturing unit, our offered filter is quality proven, highly durable & requires negligible maintenance. The provided filter is precisely designed to eradicate the harmful particles, including mold spores, dust, dust mites, pet dander and other irritating allergens from the air. Besides this, our esteemed clients can avail this filter from us at industry leading prices. We are offering our products as per client requirement. Features: Sturdiness Robust design Seamless finish

    more..
  • Modular Air Handling Systems

    Modular Air Handling Systems

    Get Price Quote

    Are you on the lookout for a company that provides HVAC Turnkey solutions? If your answer is an empathic yes, we are the right choice to opt for. We provide complete design and consultation in cleanroom mechanical systems. Our professionals are efficient enough to analyze, modify and retrofit existing cleanroom systems. They use modern techniques and tools in order to execute HVAC Turnkey Projects in an effective manner. Moreover, our experts complete HVAC Turnkey Projects in a time bound manner. One Air Handler can do the work of several motorized filter modules. Air Handlers not only pump cleanroom air, they also offer advanced climate control features not offered by fan filters. Optional capabilities such as air conditioning, humidifying and temperature control make air handling units better suited to precisely control your cleanroom environment. Whether you are building new, or upgrading to a cleaner climate, Air Handlers offer a wealth of performance benefits. Air Handler Features : Pull or produce room air through self-contained units Use a pre-filter to clean and a coil to condition the air Floor mounted outside the cleanroom saving valuable cleanroom floor space

    more..
  • Industrial Ducting

    Industrial Ducting

    Get Price Quote

    We are engaged in manufacturing & supplying of Industrial Ducting. Used in industries and factories to control pollution, the Industrial Ducting are fabricated using superior grade material and latest technology. The complete range of Industrial Ducting is manufactured as per the set industrial parameters for quality. We have a team of strict quality controllers who test the Industrial Ducting to make sure that they are durable, sturdy and reliable. Features : Easy to handle and operateDurableHighly efficientRobust construction

    more..
  • Easyflex Flexible Duct Connector

    Easyflex Flexible Duct Connector

    500 - 10,000 Per piece

    • Type: Flexible Ducts
    • Material: HVAC
    • Diameter: 0-10cm, 10-20cm, 20-30cm, 30-40cm, 40-50cm, 50-60cm, 60-70cm, 70-80cm
    • Shape: Rectangular, Round, Square
    • Certification: ISI Certified, ISO 9001:2008 Certified
    • Length: 0-50cm, 100-150cm, 150-200cm, 200-250cm, 50-100cm
    • Application: Domestic Use, Hotel Use, Industrial Use, Restaurant Use
    • Color: Grey, Metallic, Silver, White
    • Feature: Accuracy Durable, Corrosion Resistance, Dimensional, Hardend & Temper, High Quality, High Tensile
    • Feature: Flexible
    • Brand Name: Easyflex-Clim
    • Thickness: custom
    more..
  • hvac systems

    hvac systems

    Get Price Quote

    HVAC systems can be used in both single-zone and multi-zone buildings. In single-zone buildings, all rooms have the same thermal comfort and indoor air quality variables. In multi-zone buildings, users can control the set points for each zone

    more..
  • Industrial Ducting Systems

    Industrial Ducting Systems

    Get Price Quote

    Our firm holds immense experience in offering an elaborate range ofIndustrial Ducting Systems. These Industrial Ducting Systems are manufactured using high-grade material that determine their durability and flawless finish. Available in varied dimensions and technical specifications, these Industrial Ducting Systems to diverse industrial requirements. Further, we can design a duct system to correspond with the system already in use. Owing to their application specific design & qualitative features, these ducting are in high demand of our clients.

    more..
  • hvac panel

    hvac panel

    Get Price Quote

    1 Piece (MOQ)

    • Country of Origin: India
    • Outlet: Hree1/4 Inch Industrial Interchange Quick Disconnect Sockets
    • Height: 36.2 Cm
    • Depth: 12.7 Cm

    We manufacture and supply a very high-quality HVAC panels which are a fuse-less type two co-ordinated starters for supply air fans. Our HVAC panel is equipped with the facility for remote operations It becomes compatible with BMS through potential free contactsFeatures VFD Bypass provision available on request Electric insulation Facilitates the easy control of machines Longer serviceability It comes with auto-manual, local remote feature for VFD feeders All starters are provided with BMS compatibility as mandatory feature All HVAC panels are provided with one incoming MCB/MCC8 or MPCB as per consultant specifications

    more..
  • Damper Actuator

    Damper Actuator

    Get Price Quote

    SDTORK Flame Proof electric actuators are design to provide reliable and efficient operation of 90 degree quarter turn valves, dampers, etc.Actuator torques ranges from 80Nm to 3,000Nm, currently ten models are available: Compact type actuator, SD-HQ006, is also available separately.

    more..
  • coarse bubble diffuser

    coarse bubble diffuser

    250 - 1,150 Per Piece

    1 Piece (MOQ)

    • Material: Plastic
    • Shape: Round
    • Thickness: 2mm, 3mm
    • Color: Black
    • Feature: Dust Free, Fine Finishing
    • Pack Type: Carton Box
    more..
  • Duct Flange Corners

    Duct Flange Corners

    6 Per Piece

    • Material: Galvanized Iron
    • Thickness: 10-15 mm
    • Finishing: Chrome Finish
    • Rust Proof: Yes
    • Surface Treatment: Polished
    • Operating Temperature: -20 to 180 Degree C
    more..
  • HVAC System - Heating, Ventilating, and Air Conditioning

    HVAC System - Heating, Ventilating, and Air Conditioning

    Get Price Quote

    1) Cleanroom Architecture – Materials of construction and finishes are important in establishing cleanliness levels and minimizing the internal generation of contaminants from the surfaces. 2) Clean Room HVAC System – The integrity of the cleanroom environment is created by the pressure differential compared with adjacent areas through heating, ventilation and air-conditioning system. The HVAC system requirements include: Supplying airflow in sufficient volume and cleanliness to support the cleanliness rating of the room. Introducing air in a manner to prevent stagnant areas where particles could accumulate. Filtering the outside and re-circulated air across high efficiency particulate air (HEPA) filters. Conditioning the air to meet the cleanroom temperature and humidity requirements. Ensuring enough conditioned makeup air to maintain the specified positive pressurization. 3) Interaction Technology – Interaction technology includes two elements: (1) the movement of materials into the area and the movement of people and (2) maintenance and cleaning. Administrative instructions, procedures and actions are necessary to be made about the logistics, operation strategies, maintenance and cleaning. 4) Monitoring systems – Monitoring systems include a means of indicating that the cleanroom is functioning properly. The variables monitored are the pressure differential between the outside environment and the cleanroom, temperature, humidity and, in some cases, noise and vibrations. Control data should be recorded on a routine basis. HVAC SYSTEM DESIGN FOR CLEAN FACILITY HVAC systems in cleanrooms are substantially different from their counterparts in commercial buildings in terms of equipment design, system requirements, reliability, size and scale. A cleanroom differs from a normal comfort air conditioned space, in the following ways.   Increased Air Supply: Whereas comfort air conditioning would require about 2-10 air changes/hr, a typical cleanroom would typically require 20 – 60 air changes and could be as high as 600 for absolute cleanliness. The use of high efficiency filters: The use of high efficiency particulate air (HEPA) filters having filtration efficiency of 99.97% down to 0.3 microns is another distinguishing feature of cleanrooms. The HEPA filters for stringent cleanrooms are normally located at the terminal end and in most cases provide 100% ceiling coverage. Room pressurization: The cleanroom is positively pressurized (to 0.05 in-wc) with respect to the adjacent areas. This is done by supplying more air and extracting less air from the room than is supplied to it.   CHEMPHARM ENGINEERED SYSTEM INCLUDES ENERGY EFFICIENT KEY COMPONENT AS- Reciprocating/Screw/Scroll type Chiller Unit with VFD Controller. DX Unit/VRF unit Built-in PLC System for Low tonnage requirement. Hot Water Generator with Built-in PLC for Winter Heat/ Monsoon Reheat requirement. CHW/CDW pumps with VFD Drive to control the speed as per demand. Air Handler with centrifugal plug fan or DIDW Backward Curve fan has been select for controlled flow air based on the Flow & Static Pressure requirement of Varies application. Dehumidifier/ Humidifier System to Maintain the Inside RH/Tem all-round the Year. Heat recovery System to enhance the power saving. Thermal Filtration System with HEPA (H-13) or ULPA (H-14) filter where ever required as per Clean Room Classification. Factory built Square, Round or Oval Ducts having slip on or TDF type flanges based on the line / system  pressure and requirements – All ducts are built as per ASHRAE 2012 Duct construction Standard. Thermal Insulation are chosen based on Application & ambient condition but fibre free and as per ASTM standards – Standard specification / material are –Nitrile Rubber, XLPE , PU BASED , ROCK WOOL , MINERAL WOOL , GLASS etc 

    more..
  • Fan Coil Unit

    Fan Coil Unit

    Get Price Quote

    • Brand Name: AARKAYS
    • Usage: Industrial Use, Residential Use, Office Use
    • Capacity (In Tons): 1 TR TO 5 TR
    • Minimum Order Quantity: 5 Piece
    more..
  • Fresh Air Louver

    Fresh Air Louver

    Get Price Quote

    We manufacture fresh air louvers which are used for the intake of fresh air. Our air control louvers and dampers are made from extruded aluminum profiles. These louver blades are wrapped up on the main frame of the louver by an appropriate ‘l’ section aluminum filters. As an option for filtering, controlling and protecting the intake of air, we have fixed a bird screen and volume control dampers

    more..
  • Fresh Air Louver

    Fresh Air Louver

    Get Price Quote

    We manufacture fresh air louvers which are used for the intake of fresh air. Our air control louvers and dampers are made from extruded aluminum profiles. These louver blades are wrapped up on the main frame of the louver by an appropriate ‘l’ section aluminum filters. As an option for filtering, controlling and protecting the intake of air, we have fixed a bird screen and volume control dampers.

    more..
  • insulated flexible ducts

    insulated flexible ducts

    Get Price Quote

    We offer best quality of insulated ducts to our clients...  

    more..
  • Split Air Conditioner Filter

    Split Air Conditioner Filter

    Get Price Quote

    5000 Piece (MOQ)

    • Certification: RoHS
    • Efficiency: 99.99%
    • Part Type: Molded air filter,Air Filter
    • Shape: Rectangular
    • Rated Air Flow: 900 m3/h
    • Dust Capacity: 550g
    • Initial Resistance: 220Pa(22.4mmH2O
    more..
  • Pre Air Filters

    Pre Air Filters

    Get Price Quote

    10 Piece(s) (MOQ)

    • Brand Name: Carve EDM

    We present a wide range of Pre Air Filters that fits to distinct industrial applications. These industrial pre filters are used by many reputed clients for various industrial air conditioning & ventilation applications in offices, cinema halls, kitchen paint booth in automobile industries, chemicals & pharmaceutical industries, where low resistance & high dust holding capacity is essential. All pre filters designed and developed by our experts are durable and require negligible maintenance.Specifications Efficiency : standard HDPE pleated type filters have an efficiency of 90% for 10 micron size particles. Pre filters with an efficiency rating of 80 to 90% to capture 10 micron to 25 micron size particles are also available on order. Frame Type :  Available in flange or box type Frame Material standard model is constructed in galvanized steel. Other models with aluminum, anodized stainless steel frame with or without powder coating are also available on order. Filter Media : HDPE and non-woven synthetic. Sealant : PU based epoxy support large frame size models are made wobble resistant using GI, aluminum, and SS support Face Guard : No face guard with standard model is supplied On order request filter can be protected with expanded mesh on both sides Nominal Depth size is available from 1. 0 inches to 6 inches (pre HDPE pleated and rod type) Pressure Drop initial pressure drop ~2. 5mm WG and recommended final pressure drop is 5-10mm WG Operating Conditions filter can withstand temperature up to 80âºc and relative humidity of 100% at 0 condensation. Filter is washable or can be cleaned by applying air pressure and reused.   Applications Air handling units (AHUS) Air-conditioning systems Power plants Chemical and fertilizer complexes Green houses Automatic drain holes Paint shops Textile mills Cement factories Laminar air flow units Bio-safety hoods Fan filter units (FFU) Gas turbine industry Compressor Diesel engines Nuclear power station CD-ROM production industry Picture tube production industry Semi-conductor industry Aeronautical industry

    more..
    Carv Edm
    Noida
    0.0 View Profile
  • Chilled Water Ceiling Concealed Fan Coil Unit

    Chilled Water Ceiling Concealed Fan Coil Unit

    Get Price Quote

    Floor mounted fan section are available from 2000 CFM to 35000 CFM. Ceiling suspended fan section are available from 1200 CFM to 4000 CFM (Direct Driven) and 3000 CFM to 6000 CFM (Belt Driven) Calculations of cooling loads and air flow requirements for each control zone. Psychrometric analysis for critical areas, calculation of reheat figure, selections of apparatus dew points and finalizing air treatment process.     CASING : (DOUBLE / SINGLE SKIN) Rigid corrosion resistant extruded aluminium hollow framework held together with fiber glass corner joints. Double skin sand-witched panels with inner skin of 24 G (0.6 mm) plain galvanized steel sheets & outer skin of 24 G (0.6 mm) pre-coated galvanized steel sheet. Casing Panels are injected with high pressure PUF insulation having density of 38±2 kg/m³. Standard AHU models have 25 mm thick panel. Die cast aluminium hinges and nylon handle on each access door. Assembly is done using self drilling and self tapping galvanized sheet metal screws. Floor mounted Units are skid mounted. The base frame is rugged in construction made from galvanized steel sheet. Ceiling suspended fan section are also available. Double skin casing is standard. SINGLE SKIN casing in 18 / 16 gauge pre-coated GI sheet is also available as an option.     SALIENT FEATURES 200 mm extended insulated drain pan in GI / SS (Optional) 3 rows cooling and 1 row heating coil (Optional) Wide capacity range :2040 CMH to 59500 CMH 4 rows cooling coil (Optional) External static pressure of 0 , 3 , 6 and 8 mm (Optional)

    more..
Filter by Locality
top