Variabox
The new VARIABOX from NEPTUNE bals meets all requirements for a modem distributor housing and can be individually configured in 5 different sizes with versions S, M, L, XL, XXL as surface mounting or mobile combination. Category: Variabox DESCRIPTION We have the right distributor for every user. Configuration according to individual specifications on the basis of pre-defined, encoded flanges, which offer a maximum level of safety during the initial installation & / or maintenance. With their robust design in a high grade & durable , quality plastic, their good seal, the modular expansion options & many innovative extra features, the new VARIABOX proves itself even under the most adverse conditions Ready wired for installation Housing made of high-grade, impact-resistant plastic Top and bottom can be sealed together Permanently attached cover screws All CEE socket outlets with screwless,maintenance-free QUICK-CON N ECT connection technology Colours, bottom-black. top-electro grey (Housing top optionally available in the colours yellow, red, blue or silver) With high quality handle Coded flange system for maximum safety during initial installation and maintenance Fuse elements arranged below transparent, lockable operating window with user friendly OTC mechanics (one touch close) Top straight
...moreUltimate Capacitors
5KVAr, 10KVAr, 12.5 KVAR & Above Categories: PF Correction, Capacitors DESCRIPTION The Three-phase Ultima Capacitors are latest from Neptune has been designed for power factor correction in networks with high harmonic current content. They are capable of withstanding 4xIn which is Maximum in comparison to other technologies offered in the market with very low losses. The capacitor has been made by three elements connected in a delta configuration with metalization done in special profile to allow high voltage stress on the film. The elements are housed into an aluminium can and finally impregnated by resin oil. The impregnation technology allow: To treat the capacitor in a vacuum To eliminate gas and humidity from the active area – impregnate the element To control the “partial discharge effect” which is one of the reason to have precocious ageing (life longer than 200,000 operating hours)
...moreThyristor Switching Module
Thyristor Switches for Dynamic Power Factor CorrectionSystem with Harmonic Block Reactors.~ Transient Free Switching~ Used forTuned and DetunedAPFCSystems~ Compact with inbuilt Axial Fan~ High temperature protection~ Copper Busbar type Links for easy connection for all ratings~ Indications andAlarms Signals for : Power “ON” Controller Signal Capacitor Bank Firing Signal OverTemperature Fan On
...moreTariff Meter
All the success that we have made in the business remains our status as trader and supplier of Dual Tariff Meters. These offered tariff meters are specifically manufactured according to the market standards by using best material for its processing at our vendors end. We offer these tariff meters in specific stipulations accordingly the details given by our clientele. Apart from this, we provide these tariff meters in modification options at suitable rates.
...moreSurface Mounting Socket
Voltage : 200/346 up to 240/415V
Frequency : 50 and 60Hz
Socket Outlet
RM Series with Dual Setting Controller
Intelligent RM Series P.F. Controllers are used for measurement and control of P.F. control units for central reactive power compensation. The P.F. measured by Neptune RM Plus is compared with the set values and in order to provide necessary compensation. P.F. Controller switches capacitor banks ON & OFF automatically. RM Plus is Single Phase CT Sensing micro controller relay, designed for above application in 144×144 case for flush mounting with rear plug-in connectors. Microcontroller based programmable RM Plus series relays are manufactured with 8 & 12 capacitor steps. It can work either in automatic or manual mode. Features Intelligent Switching for Balanced Load Compensation Dual Target Cos Phi (For Mains & Generator PF Compensation) Password Protection Internal Temp. Control Automatic Setup Measures and displaying upto 19th harmonics for voltage & current Programmable discharge time Automatic calculation of power values for each capacitor step Auto / Manual mode selection 10 different programs C+ / NORMAL / C- condition light Automatic calculation on C/k value Automatic calculation on C/k value Optional temperature control with J type T/C input Insufficient compensation alarm Over compensation alarm Programmable over voltage protection and alarm for capacitors Automatic disconnection of all capacitor steps in case of Mains failure over 20 sec. Programmable CT and PT ratio setting Non-flammable enclosure
...morereal time power factor correction system
Real Time Thyristor Switched Dynamic Power Factor Correction System & Harmonic Filtration System Categories: Power Factor Improvements, Power Quality Fast Real Time Transient-Free switching of Capacitor Banks Prevents damage to sensitive electronic equipment in notwork Highly intelligent micro processor based 3 phase P.F. Controller with Dual P.F. Setting and Master Slave modes LCD Controller has inbuilt with Load Manager with front optical port Optional plugable Data Logger, Ethernet, USB, Rs485, GSM modern and capacitor protection modules Saves Energy with P.F Control and Harmonic Filtration Extremely long life expectancy Integral 3 phase Power Quality Analyze showing upto 31st Harmonics Voltage & Current Waveforms Unique Self Testing and Comprehensive reporting and event logging The compensation is based on averaging the FFT analysis of each cycle, resulting in more accurate compensation, even in the presence of harmonic Available with Tuned, 7%, 5.6%, 4% or any other Tuning frequency as per customer request System is available with Contactor switching for non-dynamic and normal loads – Ratings and Dimensions are same as Activcomp System
...moreReactive Energy Management
REM-308/REM-C-312 Available in 8 Stages and 12 Stages Categories: PF Correction, Power Factor Controller
...morePower Factor Controller
PM-108/PM-112 Available in 8 Stages and 12 Stages Categories: PF Correction, Power Factor Controller
...morePower Factor Improvement
Higher KVAR Ratings are also available on demand. Power Factor APFC (With capacitor / With capacitor & Line Reactor) SKU: N/ACategories: PF Correction, Power Factor Improvements Available from 25 KVAR TO 325 KVAR in Series-I and Series-II Heavy Duty 3 Phase Cylinderal Capacitor Expandable Intelligent PF Control for small medium load networks Ultimate solution for compensation of unbalanced loads Measure the reactive power of the system through 3CT’s from all 3 phase Highly intelligent Micro processor baseed 3 phase P.F. Controller with optional Dual P.F. Setting LCD Controller with inbuilt Load Manager with front optical port Optional Plugable Data logger, Ethernet, USB, RS485, GSM modern and capacitor protection modules Powder Coated-Structure finish with altractive Deep Orange and Dark Blue finish Incomer TPMCCB HRC/HCB’s are used for backup protection
...morePlug water tight
passive harmonic filters
Helps meet IEEE-519 requirements Gurantees THDi performance of 8% Max at 50% load, 5% Max at full load Meets the voltage and current distortion limits of IEEE-519 Saves energy by eliminating the wasted energy associated with harmonics, therefore reducing the true RMS KVA demanded from your power source. Suitable for speed controllers or inverters Reduces energy costs Increases equipment reliability by absorbing transients and voltage surges Increases equipments life by reducing heat associated with harmonic currents Improves power factor Reduces THD-V to meet power quality standards. Categories: Power Quality, Power Quality Solutions Most of the mentioned filtering techniques have common drawback of higher cost compared to Passive Filtering techniques. Consequently, the harmonic filtering techniques to a large extent are still the most commonly used techniques for current harmonics mitigation of 6-pulse front-end diode rectifier application. We have developed an efficient Passive Filter, which can suit many such similar loads. Since all filter components are passive they are rugged, maintenance free, reliable and low cost. Moreover, the filter implementation procedure is relatively easy. With simple structure, our Passive Filters have been extensively used for VFD harmonic mitigation. No involvement of electronic circuits, hardware and complicated control algorithms. Hence, our Passive Harmonic Filters are relatively inexpensive means for eliminating current harmonics distortion and improving the system power factor. Because of these two in one improvement our broad band filters usually have edge over the other effective filtering methods.
...morePanel Mounting Socket
Panel Mounting Appliance
Appliance Inlet IP-44: 32 Amp 5 Pin SKU: 2600Categories: Industrial Plug & Sockets,Domestic/Industrial AC Outlet
Voltage : 200/346 up to 240/415V
Frequency : 50 and 60Hz
...moreModular Distribution Board
Our Modular Distribution Board Provides optimum security to both operations and equipment because they feature total insulation and protection degree IP 65 according to IEC 60529 and EN 60529. DESCRIPTION Impact resistant modular polycarbonate distribution boards Chemical resistant Solid and Stable Self-extinguishing Weather Resistant Corrosion free screws
...moreJunction Boxes
Our Modular Distribution System Provides optimum security to both operations and equipment because they feature total insulation and protection degree IP 65 according to IEC 60529 and EN 60529. DESCRIPTION Impact resistant modular polycarbonate enclosures Chemical resistant Solid and Stable Self-extinguishing Weather Resistant Corrosion free screws Self internal fixing centre / fixing centre outside Cable entry to client’s specifications
...moreHybrid Filters
Rating (Dynamic Reactive Compensation + Active Filter)300 KVAR + 60A400 KVAR + 100A500 KVAR + 150A600 KVAR + 200A800 KVAR + 300AAny other rating on request Categorie DESCRIPTION Hybrid Power conditioning system is a combination of Dynamic Activcomp Thyristor based Power Factor Correction System and IGBT fired Active Harmonic Filtration System offers most viable and economical solution for both Power Factor Compensation and Harmonic Mitigation. The designs offered by us are installed for compensation and Harmonic compliance of main transformer or at major load feeders. Though there are standard ratings but any design can be offered as per customer load characteristics and level of harmonic distortion.
...moreHeavy Duty Capacitor
The capacitors making up the POWER-9 series are used for static power factor correction of a wide range of motors and transformers. This series share the same internal configuration, with three capacitor elements wired internally in a delta connection. The overpressure protection system is specifically dimensioned so as to constantly ensure maximum safety in terms of ground protection and protection against the risk of arcing, even in conditions where there is a high energy density. In these series HEAVY DUTY of resin-impregnated capacitors, the three elements are housed in a plastic container which, together with the impregnating agents, assures dual insulation between the wound cores and metal enclosure. To guarantee perfect filling during the resin impregnation process, the process itself is carried out prior to the elements being placed in the enclosure; in this way the distribution and uniformity of the impregnation can be subjected to a complete visual and dimensional inspection.
...moreHarmonic Block Reactors
Design Features Neptune filter circuit are designed as three-phase reactors with an iron core and air gap. Harmonic Filter Reactors are made out of highest quality material and very stringent quality control. It has been designed with properties like low temperature rise and lower flux density so that it can operate in worst conditions of ambient and harmonic overloads. They offer very good degree of linearity. Cheaper and non-linear reactors may trigger undesirable chain phenomena during periods of operation with high harmonic values, such as reducing in the inductance with consequent increase in the resonance frequency of the LC group, which would drain off more harmonic current, further reducing its inductance and overload the reactor more and more. Reactors are available with filtering factor of 7% and 14% in 12.5, 25, 50 and 100 KVAR rating. Any other filtering factor and rating can be made on request.
...moreDual Energy Meter
VL-L, VL-N Phase wise & Avg.Ampere phase wise & Avg. Hz,PF Phase wise & system, Active,Reactive & ApparentPower phase wise & Total,Active energy, Reactive inductive energy,Energy 0.1 kWh, PF 0.001, Hz 0.01 & Auto ranging for Voltage, Current & Power.
...moreactive harmonic filters
Active filters are power electronic devices connected in parallel with the load to be compensated. The device can be thought of as a controlled current source, which provides any kind of current waveform in real time.When connected in parallel with the nonlinear load, its harmonic currents are compensated and the network is loaded with fundamental current only. The control system monitors the relevant parameters of the network and is capable of detecting and instantaneously reacting to any disturbance in the load current. Our AHF series is an advanced modular Active Harmonic Filter (AHF) system. The AHF system is constructed of one or several filter modules with system controller. Filter modules and controller, both are embedded in our standard cabinets. CT terminations are fixed in a standard cabinet, and the AHF capacity can be configured accordingly to user requirement. The filter capacity can be easily expanded at the user’s site by adding extra filter modules as per site requirement. Flexibility: Designers have more choices with flexible configuration Capability to expand vertically as well as horizontally Higher operating temperature up to 50 Deg. C. Reliability: IGBT paralleling technology Intelligent air cooling technology High quality components of international brands Advanced production technology
...morelt power capacitors
Capacitor Panel
Be first to Rate
Rate ThisOpening Hours