Welding Water Cooler Dealers in Noida

(2 products available)
  • InRow Chilled Water Cooling

    InRow Chilled Water Cooling

    Get Price Quote

    Close-coupled, chilled water cooling for medium to large data centersExplore InRow RC in 3D animation.The InRow Chilled Water unit closely couples the cooling with the IT heat load. This prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available with and without humidity control, these products are intended to meet the diverse requirements for medium to large data centers. Data center operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow Chilled Water products. The intelligent controls of the InRow Chilled Water products actively adjust fan speed and chilled water flow to match the IT heat load to maximize efficiency and address the dynamic demands of today's IT environments. Serviceability Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors. Agility Casters Provides flexibility to move the unit to wherever cooling is required. Scaleable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures. Modular design Modular design provides scalable solutions to add cooling as demand increases. Total Cost of Ownership Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods. Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures. Availability Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy. Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment. Manageability Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system. Real-Time Capacity Monitoring Real-time display of current and available cooling. Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.

    more..
  • Chilled Water Ceiling Concealed Fan Coil Unit

    Chilled Water Ceiling Concealed Fan Coil Unit

    Get Price Quote

    Floor mounted fan section are available from 2000 CFM to 35000 CFM. Ceiling suspended fan section are available from 1200 CFM to 4000 CFM (Direct Driven) and 3000 CFM to 6000 CFM (Belt Driven) Calculations of cooling loads and air flow requirements for each control zone. Psychrometric analysis for critical areas, calculation of reheat figure, selections of apparatus dew points and finalizing air treatment process.     CASING : (DOUBLE / SINGLE SKIN) Rigid corrosion resistant extruded aluminium hollow framework held together with fiber glass corner joints. Double skin sand-witched panels with inner skin of 24 G (0.6 mm) plain galvanized steel sheets & outer skin of 24 G (0.6 mm) pre-coated galvanized steel sheet. Casing Panels are injected with high pressure PUF insulation having density of 38±2 kg/m³. Standard AHU models have 25 mm thick panel. Die cast aluminium hinges and nylon handle on each access door. Assembly is done using self drilling and self tapping galvanized sheet metal screws. Floor mounted Units are skid mounted. The base frame is rugged in construction made from galvanized steel sheet. Ceiling suspended fan section are also available. Double skin casing is standard. SINGLE SKIN casing in 18 / 16 gauge pre-coated GI sheet is also available as an option.     SALIENT FEATURES 200 mm extended insulated drain pan in GI / SS (Optional) 3 rows cooling and 1 row heating coil (Optional) Wide capacity range :2040 CMH to 59500 CMH 4 rows cooling coil (Optional) External static pressure of 0 , 3 , 6 and 8 mm (Optional)

    more..
  • Best Deals from Welding Water Cooler

Filter by Locality
top