Syringe Pump Dealers in Panipat

(6 products available)
  • Syringe Infusion Pump

    Syringe Infusion Pump

    19,000 Per Piece

    10 Piece (MOQ)

    • Type: Infusion Pump
    • Weight: 3 Kg
    • Usage/Application: Bulk Fluid Injection
    • Number Of Syringes: 1
    • Infusion Mode: Rate Mode
    • Display Type: Digital
    • Power Source: Electric
    • Dimension: 10 x 8 x 3 inch (W x L x H)
    more..
    Yes Medi Pulse
    Panipat
    0.0 View Profile
  • Syringe Pump

    Syringe Pump

    Get Price Quote

    2 Piece(s) (MOQ)

    • Brand Name: globalmedicare
    • single channels: white

    We offer Syringe Pump. Additional Info. Packing: Paper Box Standard: ISO9001; ISO13485; CE Origin: China Company: Beijing Xin He Feng Medical Technology Co., Ltd. Product Description Model FA312 Syringe Selection: 10ml 20ml 30ml 5060ml Infusion volumn: 0-999.9ml, 0.1 step Display volumn infused: 0-999.9ml Accuracy: ± 2%; Eliminate the mechanical clearance according to appendix C and calibrate the accuracy to ensure the normal running. Infusion rate: 0.1-200ml, 0.1 step; Using 50ml60ml Syringe 0.1-200ml, 0.1 step; Using 30ml Syringe 0.1-200ml, 0.1 step; Using 20ml Syringe 0.1-99.9ml, 0.1 step; Using 10ml Syringe Highest infusion rate: 200ml Purge rate: 200ml; Using 50ml Syringe 200ml; Using 30ml Syringe 200ml; Using 20ml Syringe 99.9ml; Using 10ml Syringe Alarms: Syringe installed failure alarm, Ocllusion alarm, infusion approaching--empty alarm, pause overtime alarm, low-battery alarm, completion of presetting volumn alarm, power intermitting alarm, motor failure alarm, incorrect spec alarm, electricalcircuit jam alarm Power Consumption: 19VA Occlusion alarm pressure: High: 20ml30ml50ml60ml Syringe Spec: 90Kpa± 30Kpa; 10ml Syringe Spec: 100Kpa± 30Kpa Occlusion alarm pressure: Low: 20ml30ml50ml60ml Syringe Spec: 50Kpa± 30Kpa; 10ml Syringe Spec: 70Kpa± 30Kpa KVO Rate: 0.1mlh ± 0.02 mlh Pause overtime alarm: 1min50s_2min Automatic recovery time after releasing the alarm if it's erasable: 1min50s_2min Power: AC: 100V-240V 50Hz60Hz Battery Type: Ni-MH DC12V--14V Working environment: A) Operating Temperature: +5 degree centigrade ~+40degree centigrade; B) Ralative Humidity: 20%~90%; C) Atmospheric pressure: 700hPa~1060hPa; D)Avoid strong vibration or corrosive air in the operating environment Dimention: 290× 130× 130mm Wight: 2.0Kg

    more..
  • Best Deals from Syringe Pump

  • Syringe Pump

    Syringe Pump

    25,000 Per Piece

    1 Piece (MOQ)

    • Type: Infusion Pump
    • Weight: 2.25 kg
    • Voltage: AC 220 V
    • Model Name/Number: SN-50C6
    • Brand: SINO MDT
    • Syringe Size: 10ml, 20ml, 30ml, 50ml
    • Number Of Syringes: 1
    • Battery Type: inner NiMH battery:DC 12 V
    • Alarm Type: 'Occlusion', 'Nearly empty' ,'Battery low', 'Finish', 'over flow rate ', 'Syringe dislocated'
    • Certification: ISO13485
    • Purge Rate: 1500ml/h, 900ml/h, 600ml/h 400ml/h
    • Operating Ambient Temperature: 40 Degree Celsius
    • Relative Humidity: 80 %
    • Storage Ambient Temperature: -20 to 55 Degree Celsius
    • Storage Relative Humidity: Less Than 95 %
    • IP Rating: IPX4
    • Dimensions: 306 x 135 x 127 mm
    • Frequency: 60 Hz
    more..
  • Syringe Pump

    Get Price Quote

    • Brand Name: Global Medicare

    We are offering Syringe Pump. Product Description Model FA312 Syringe Selection: 10ml 20ml 30ml 5060ml Infusion volumn: 0-999.9ml, 0.1 step Display volumn infused: 0-999.9ml Accuracy: ± 2%; Eliminate the mechanical clearance according to appendix C and calibrate the accuracy to ensure the normal running. Infusion rate: 0.1-200ml, 0.1 step; Using 50ml60ml Syringe 0.1-200ml, 0.1 step; Using 30ml Syringe 0.1-200ml, 0.1 step; Using 20ml Syringe 0.1-99.9ml, 0.1 step; Using 10ml Syringe Highest infusion rate: 200ml Purge rate: 200ml; Using 50ml Syringe 200ml; Using 30ml Syringe 200ml; Using 20ml Syringe 99.9ml; Using 10ml Syringe Alarms: Syringe installed failure alarm, Ocllusion alarm, infusion approaching--empty alarm, pause overtime alarm, low-battery alarm, completion of presetting volumn alarm, power intermitting alarm, motor failure alarm, incorrect spec alarm, electricalcircuit jam alarm Power Consumption: 19VA Occlusion alarm pressure: High: 20ml30ml50ml60ml Syringe Spec: 90Kpa± 30Kpa; 10ml Syringe Spec: 100Kpa± 30Kpa Occlusion alarm pressure: Low: 20ml30ml50ml60ml Syringe Spec: 50Kpa± 30Kpa; 10ml Syringe Spec: 70Kpa± 30Kpa KVO Rate: 0.1mlh ± 0.02 mlh Pause overtime alarm: 1min50s_2min Automatic recovery time after releasing the alarm if it's erasable: 1min50s_2min Power: AC: 100V-240V 50Hz60Hz,Battery Type: Ni-MH DC12V--14V Working environment: A) Operating Temperature: +5 degree centigrade ~+40degree centigrade; B) Ralative Humidity: 20%~90%; C) Atmospheric pressure: 700hPa~1060hPa; D)Avoid strong vibration or corrosive air in the operating environment Dimention: 290× 130× 130mm Wight: 2.0Kg.

    more..
  • Syringe Pump

    Syringe Pump

    Get Price Quote

    Para Monitor

    more..
  • Syringe Pump

    Get Price Quote

    We are offering a wide range of quality syringe pumps in India.

    more..
Filter by Locality
top