Fire Hydrant System
Get Price Quote
* We Offer Fire Hydrant Valve, Single Oblique Outlet.body / Female Inst. Oblique Outlet (63mm Size) with Pull Out Type Lug Made of Gunmetal / Ss, 75mm N.b. Flanged Inlet, Spindle Made of Brass /ss and Hand Wheel Made of Cast Iron (is: 210), Complete with Abs / Pvc Blank Cap & Chain, Bearing Bis: 5290 Mark, Flange Dimension: O.d. 200mm, Pcd 160mm, Four 19m Dia Holes * Fire Hydrant Valve, Right Angle Type Single Outlet :body Made of Gunmetal, Is: 318 Ltb 2 Grade, 75mm N.b. Flanged Inlet, 63mm Female Inst. Right Angle Type Outlet, Spindle Made of Brass and C.i Hand Wheel, Complete with Abs Blank Cap & Chain, Bearing Is: 5290 Mark, Flange Dimension: O.d. 200mm, Pcd160mm, Four 19mdia Holes * Double Hydrant:fire Hydrant Valve, Double Individually Controlled Outlets. Body/ Female Inst. Outlets (two Nos. of 63mm Size) with Pull Out Type Lug Made of Gunmetal / Ss, with 100mm N.b. Flanged Inlet, Spindle Made of Brass / Ss , Complete with Abs / Pvc Blank Caps and Chains, Bearing Bis:5290 Mark, * Stand Post Type Fire Hydrant – Double / Single Outlet * M.s. Post with Flanged Inlet, with Double Outlets 80mm N.b. Flanged Diagonally Opposite, - Complete with Two / One Fire Hydrant Valve – Single Oblique Outlet, Material Gunmetal ( Is: 318 Ltb2 Grade), 80mm N.b. Flanged Inlet, Brass Spindle, 63mm Female Inst. Oblique Outlet as per Is: 903, Complete with Abs Blank Cap & Chain, Bearing Is: 5290 Mark, - Set of Nut Bolts and Gasket for Each Hydrant Will Be Provided. - Flange Drilling Dimension Will Be as per Ansi B 16.5 Class 150 * Fire Hydrant – Underground : Made of Cast Iron, 80mm N.b. Flange Inlet, Gm 63mms Male Round Threaded Outlet, with C.i. Cover Cap and Chain, Conforming to Is: 909 Type-2, Flange Dimension: O.d. 200mm, Pcd 160mm, Four 19mdia Holes (otherwise as Specified By Client)hydrant Key, Made Out of Al. Alloy * Pressure Reducing (controlled Pressure) Hydrant Valve – Made of Copper Alloy (is:318-ltb Gr.-2) – with 63mm Flanged Inlet Drilled as per Ansi B 16.5 Class 150 & Integrated 63mm Size Female Instantaneous Outlet, Brass Spindle, Cast Iron Hand Wheel, – Duly Hydro-tested At 21 Bar Pressure, Dully Painted – Fire Red Colour, * Pressure Restricting Valve : Made of Copper Alloy(is:318-ltb Gr.-2), Having 50mm Size Nh/nst/bsp (f) Threaded Inlet with 50mm Size Nh/nst(m) Threaded Outlet, Light Alloy Hand Wheel, Natural Finish * Stand Post Type Fire Hydrant – Four Outlet, 600 Mm High X 150 Mm (6”) Nb M.s. Post with Flanged Inlet, Having Four Outlets 75mm N.b. Flanged Type. Complete with Four Nos. Fire Hydrant Valve, Single Oblique Outlet Body, Female Inst. Oblique Outlet (63mm Size) with Pull Out Type Lug Made of Gunmetal, Is: 318 Ltb 2 Grade, 75mm N.b. Flanged Inlet, Spindle Made of Brass (is:319) and Hand Wheel Made of Cast Iron (is: 210), Complete with Abs Blank Cap & Chain, Bearing Bis: 5290 Mark, Set of Nut Bolts and Gasket for Each Hydrant Will Be Provided.flange Drilling Dimension Will Be as per Ansi B 16.5 Class 150.
fire hydrant pumps
Get Price Quote
1 Piece (MOQ)
Fire Hydrants The fire hydrant system is the backbone of the fire fighting systems in a building or premises . The purpose of the fire hydrant system is to provide a readily available source of water to any point throughout the building or premises . This helps in controlling fire during an emergency.
Best Deals from Fire Hydrant Pumps
Fire Hydrant System
Get Price Quote
Fire Hydrant System
2,500,000 Per Unit
1 Piece (MOQ)
Fire Hydrant System
Get Price Quote
Fire Hydrant Pump System
500,000 Per Piece
Fire Hydrant System
Get Price Quote
10 Piece (MOQ)
Fire Hydrant System
Get Price Quote
Fire Hydrant System
Get Price Quote
1 Unit (MOQ)
IS IT ALWAYS NECESSARY TO PROVIDE FIRE PROTECTION WITH FIRE HYDRANT SYSTEMS? Fire Hydrant Systems forms the basis, of Fire Protection Systems, without Fire Hydrant System a Fire Protection System cannot be called a Fire Protection System. It will be a superficial system. (With respect to large areas, in general). Fire Hydrant System installation is relatively easy. HOW DO FIRE HYDRANT SYSTEMS FUNCTION? A special well is dug, called "Fire Well", where water is stored throughout the year for 365days. This water well is connected to the pump room. From the pump room, there are two to three main pipes. These pipes form a network of pipe that cover the factory compound and the factory. The pump has the work, to continuously filling all the pipes connected with water under pressure. The pressure is nearly 7bar to 10bar. When a fire is seen by a person, he activates the hydrant system and points it in the direction of the fire. A very strong flow of water now, attacks the fire and the fire is eventually extinguished. The pump continuously pumps the water to maintain the system pressure. WHAT ARE THE ADVANTAGES OF FIRE HYDRANT SYSTEMS? Fire Hydrant Systems are very strong and can be used from medium to large sized fires. Fire Hydrant Systems, have a long range. Since the Fire Hydrant System is spread out, the fire hydrant can attack fire from different angles. This entire system requires low maintenance and virtually, does not leak water. Besides this, Fire Hydrant Systems have a long life. WHAT ARE THE DISADVANTAGES OF FIRE HYDRANT SYSTEMS? There are few disadvantages. The first is that it has to be manually activated. The flow of Fire Hydrant System is so strong that, there are two men required to hold the water hose. Fire Hydrant System may cause damage to the instruments or machines. Fire Hydrant systems are very popular and hence many, Clients search only for Fire Hydrant Companies or Fire Hydrant System Suppliers; but the important thing to understand is that it may not be the most efficient system.
Fire Hydrant System
Get Price Quote
50 Piece (MOQ)
Fire Hydrant System
Get Price Quote
Based in Faridabad(India), we are listed amidst the most celebrated names offering a spectrum of products. Buyers can place bulk or retail orders with us all year round and expect on time delivery of consignments.
Fire Hydrant System
Get Price Quote
Ours is the name involved in the business of supplying highly efficient Fire Hydrant System. It is widely used for providing protection against fire occurs in the entire plant, building, etc. The system comprises of underground & above ground piping all over the protected area. The entire network is pressurized with water using pumps, which are connected to a water source. Moreover, our Fire Hydrant System is reasonably priced.
Fire Hydrant System
Get Price Quote
Being one of the oldest but yet the most effective and common fire fighting solutions , as well designed and laid out Hydrant system forms the backbone of the entire fire fighting system.We are highly acknowledged as the best Service Provider of Hydrant System Fire. It is highly demanded in various buildings or premises, widely used for fire fighting solutions and helps in controlling fire during an emergency. This system is designed to suppress the fire and provide a readily available source of water to any point. Under the supervision of our team of well-trained professionals, the offered system is installed by using the modern tools & techniques and quality-tested components. Apart from this, we are offering the Hydrant System Fire in different specifications at affordable prices.The fire hydrant systems are access points that allow fire authorities to connect hoses and quickly disperse large amounts of water to extinguish flames.The system mainly consists of by a number of components & accessories like Fire pumps ( Jockey Pump, Electric Driven Pump, & Stand-by Diesel driven pump) Fire pumps are usually housed in a pump room very close to the fire tanks. The key thing is that the pumps should be located at a level just below the bottom of the fire tank, so that all the water in the tanks can flow into the pumps by gravity.Like all important systems, there must be backup pumps in case the main pump fails. There is a main pump that is electric, a backup pump that is electric, and a second backup pump that is diesel-powered, in case the electricity fails, which is common. Each of these pumps is capable of pumping the required amount of water individually - they are identical in capacity.There is also a fourth type of pump called a jockey pump. This is a small pump attached to the system that continually switches on to maintain the correct pressure in the distribution systems, which is normally 7 Kg/cm2 or 100 psi. If there is a small leakage somewhere in the system, the jockey pump will switch on to compensate for it. Each jockey pump will also have a backup., The capacity of the pumps is decided by considering a number of factors, some of which are:the area covered by hydrants / standpipes and sprinklers The number of hydrants and sprinklers The assumed area of operation of the sprinklers The type and layout of the building Dry Rising Main (Dry Riser). A vertical pipe installed in a building for fire fighting purposes, fitted with inlet connections at fire engine access level and landing valves on various floors, which is normally dry but is capable of being charged with water usually by pumping from fire engine pumps. Dry rising mains are basically dry water pipes. The empty mains need to be charged with water through the breeching inlets by fire appliance. The dry rising mains should not exceed 60m to avoid excessive pumping pressure.Wet Rising Main (Wet Riser). A vertical pipe installed in a building for fire fighting purposes and permanently charged with water from a pressurized supply, and fitted with landing valves on various floors. Wet rising mains are constantly charged with water that provide the required flow rate and pressure for fire fighting and equipped with water storage capacity for a given duration of 60 minutes. The breeching inlets, which are usually provided at ground level, are meant for replenishing the water tank.The distribution system consists of steel or galvanised steel pipes that are painted red. These can be welded together to make secure joints, or attached with special clamps. When running underground, they are wrapped with a special coating that prevents corrosion and protects the pipe. External (Stand Post Type Or Underground Type – Sluice Valve, Water Monitor)The amount of water in the fire storage tanks is determined by the hazard level of the project under consideration. Most building codes have at least three levels, namely, Light Hazard (such as schools, residential buildings and offices), Ordinary Hazard (such as most factories and warehouses), and High Hazard (places which store or use flammable materials like foam factories, aircraft hangars, paint factories, fireworks factories). The relevant building code lists which type of structure falls in each category. The quantity of water to be stored is usually given in hours of pumping capacity. In system with a capacity of one hour, the tanks are made large enough to supply the fire with water for a period of one hour when the fire pumps are switched on. For example, building codes may require light hazard systems to have one hour’s capacity and high hazard 3 or 4 hours capacity. The water is usually stored in concrete underground tanks. It is essential to ensure that this store of water always remains full, so it must have no outlets apart from the ones that lead to the fire pumps. These tanks are separate from the tanks used to supply water to occupants, which are usually called domestic water tanks. Designers will also try and ensure that the water in the fire tanks does not get stagnant and develop algae, which could clog the pipes and pumps, rendering the system useless in a fire.Guidelines and approval for hydrant system are available from various national and international organizations like NBC, NFPA,TAC,IS,FM & Local Authorities.
Fire Hydrant System
1,850 Per Mtr
1 Mtr (MOQ)
Fire Hydrant System
Get Price Quote
Equipped with the exceptional machines and leading technologies, we are instrumental in offering the best in class products that are stringently packed under the supervision of experts. We are immensely accredited for delivering the orders within the stipulated time frame as we have the latest transportation facilities.
Fire Hydrant System
Get Price Quote
We are offering a wide range of premium Fire Hydrant System. Fire Hydrant System is used in various industries, owing its outstanding performance and high speed. Fire Hydrant System is useful for facilitating workers to work safely and effectively. It is offered at reasonable prices.
Fire Hydrant System
Get Price Quote
We offer a range of FIRE HYDRANT SYSTEM and YARD HYDRANTS with all required accessories. Some of the feature of this systems are as follows - HYDRANT SYSTEM The Hydrant System comprises of AC motor driven pump sets with all required accessories including valves, instrumentation and controls etc. Complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent. Pipe work from the fire water pump set. The hydrant pipe work is remaining pressurized through the proposed jockey pump taking care of any leakages in the system pipe lines, valves and fittings. The hydrant system is kept charged by pressurized water at approx. 7 Kg. Cm. Sq. at all times. In the event of fire when any of the hydrant valves in the net work is opened,the resultant fall in pressure system is enabling starting the AC MOTOR driven fire water pumping set through pressure switches automatically. One diesel engine pump shall be standby pump serving hydrant system. Apart from the automatic starting of the pump sets,provision shall be kept for manual starting also. Shutting down of the pump sets shall be manual. YARD HYDRANTS Hydrants inside the building is furnished with required accessories such as hose pipes with instantaneous gun metal couplings and g.m branch pipes located in hose cabinets. The hose cabinets is wall / column mounting type, constructed out of 18 gauge mild steel sheets. The internal hydrants ( Landing valves) is single headed type taken out from 150/100 mm dia riser through suitable reducer. The outlets is gun metal and confirm to IS : 5290. HT Hose reels is firmly held against the wall by suitable heavy brackets and supports. The hose reel is swinging type ( 180 deg.) and the entire Dum reel etc. is as per IS : 3876. The rubber tubing is best quality ( Dunlop ) and the nozzle is 6 mm dia. Shut off type. The equipment shall be out of one of the approved makes. The hydrant main is laid in the form of ring main. The hydrant risers is terminated with air release valves at the highest points to release the trapped air in the pipe work.
Fire Hydrant Pump System
Get Price Quote
Fire Hydrant System
Get Price Quote
Fire Hydrant System
Get Price Quote
Fire Hydrant System, Sprinklers System, Water Spray System (HVW / MVW), CO2 Flooding System, Wet Riser System, Foam Monitor System and water mist system. We are Authorized Dealer of all kind of Fire Fighting Equipment’s & Accessories like:- Sprinkler, Hydrants, Fire Extinguishers, Hose Box, Water Monitor, SS Flexible Hose, spray nozzles, Hose Pipe, Hose