Portable Light Tower
300,000 - 350,000 Per Piece
Tower Light - 4*1000W Winch - Manual Outriggers - 4 Fuel Tank Capacity in Lits - 45 Spark Arresters - Nil Lifting Eyes - 9 Meter Dry weight in Kgs - 875 Operating Weight in Kgs - 920 Mast Stowed (LXWXH) without light & its bracket in mm - 4200*1400*1550 Mast Stowed (LXWXH) with light & its bracket in mm - 4400*1600*1700 Engine Make - Mitsubishi Model - MVL3E-63 JGSB Cooling - Liquid Aspiration - NA No. of Cylinders - 3 RPM - 1500 Compression Ratio - 23:01 Bore Stroke(mm) - 76*70 Cubic Capacity(Its) - 0.952 Power(HP) - 9.4 Governing* - Mechanical Starting System - 12V Electrical Lube Oil Specification - SAE 20/40 Lube Oil Sump Capacity in lIts - 4.7 Fuel Consumption on Lighting per Hrs - 1.5 Fuel Consumption on Aux Power Drop per Hrs - 1.2 Fuel Consumption on both Lighting & Aux Power per Hrs - 2.6 Fuel Consumption on 75 % load per Hrs - 2 Max Operating ambient temp - 0- 45 Degree Celsius Generator Make - Lerry Somer Model - LSAP 40 C1 Power Rating(KVA/KW) - 7 KVA/5.6 KW No. of Phases - 1 Power factors - 0.8 Current@0.8(Amps) - 28.7 Amps Battery Rating - 12V-65AH Alternator - 7KVA Voltage - 240 Frequency - 50 Voltage Regulation (max.) - ± 1% Insulation - Class H Enclosure - IP23 Lights Lumens - 4,20,000 Protection - IP55 Type - Metal Halide Auxiliary Power Power Out - 1.6 Kw Running Gear Tyre size - 185/70-R14 Max Hub/ Axial Rating Capacity - 1530 Kg Max Towing Speed - 40 KM/HR Sound Level - 70 Dba Mast Rotation - 0 TO 355 degree ADVANTAGES Fuel tank is easily removable at the time of engine and alternator service. Usage of derlin sheet to reduce the friction between the sliding towers. Better structural design for tower rest. Compact control panel design. Silencer exhaust is provided near the bottom of canopy to avoid hot air exhaust direct to the operating person. Tower self lock is available at vertical position to reduce the roop stress Jack height from floor level is 10 inch while other suppliers are using 6 inch jack only. Cost of Door hinges are less and easily available in market. Larger doors provide for better space and easy service. Engine safety is indicated by lamp. We provide voltmeter to measure voltage which is not available in other supplier Models We provide ammeter to measure amps which is not available in other supplier models. We provide door lock key to ensure the safety of Machines Easy and trouble free control panel. We provide identification marks for switches in each light. We provide knob lock for tower pivot it is easily handled. Usage of MCB switch trip Prevent the short circuit damege if any .
Application : Park, Sports Ground, Weddings
...moreLT-400 Light Tower
300,000 - 350,000 Per Piece
1 Piece (MOQ)
Tower Light - 4*400W Winch - Manual Outriggers - 4 Fuel Tank Capacity in Lits - 45 Spark Arresters - Nil Lifting Eyes - 9 Meter Dry weight in Kgs - 860 Operating Weight in Kgs - 905 Mast Stowed (LXWXH) without light & its bracket in mm - 4200*1400*1550 Mast Stowed (LXWXH) with light & its bracket in mm - 4350*1600*1700 Engine Make - Mitsubishi Model - MVL3E-63 JGSB Cooling - Liquid Aspiration - NA No. of Cylinders - 3 RPM - 1500 Compression Ratio - 23:01 Bore Storke(mm) - 76*70 Cubic Capacity(Its) - 0.952 Power(HP) - 9.4 Governing* - Mechanical Starting System - 12V Electrical Lube Oil Specification - SAE 20/ 40 Lube Oil Sump Capacity in lIts - 4.7 Fuel Consumption on Lighting per Hrs - 1.2 Fuel Consumption on Aux Power Drop per Hrs - 0.9 Fuel Consumption on both Lighting & Aux Power per Hrs - 2 Fuel Consumption on 75 % load per Hrs - 1.4 Max Operating ambient temp - 0- 45 Degree Celsius Generator Make Lerry Somer Model - LSAP 40 C1 Power Rating(KVA/KW) - 5KVA/4KW No. of Phases - 1 Power factors - 0.8 Current@0.8(Amps) - 20.5 Amps Battery Rating - 12V-65AH Alternator - 5KVA Voltage - 240 Frequency - 50 Voltage Regulation(max.) - ± 1% Insulation - Class H Enclosure - IP23 Lights Lumens - 1,40,000 Protection - IP55 Type - Metal Halide Auxiliary Power Power Out - 2.4 Kw Running Gear Tyre size - 185/70-R14 Max Hub/ Axial Rating Capacity - 1530 Kg Max Towing Speed - 40 KM/HR Sound Level - 70 dBA Mast Rotation - 0 TO 355 degree ADVANTAGES Fuel tank is easily removable at the time of engine and alternator service. Usage of derlin sheet to reduce the friction between the sliding towers. Better structural design for tower rest. Compact control panel design. Silencer exhaust is provided near the bottom of canopy to avoid hot air exhaust direct to the operating person. Tower self lock is available at vertical position to reduce the roop stress Jack height from floor level is 10 inch while other suppliers are using 6 inch jack only. Cost of Door hinges are less and easily available in market. Larger doors provide for better space and easy service. Engine safety is indicated by lamp. We provide voltmeter to measure voltage which is not available in other supplier Models We provide ammeter to measure amps which is not available in other supplier models. We provide door lock key to ensure the safety of Machines Easy and trouble free control panel. We provide identification marks for switches in each light. We provide knob lock for tower pivot it is easily handled. Usage of MCB switch trip Prevent the short circuit damage if any .
...moreLT 1000 Light Tower
300,000 - 350,000 Per Piece
1 Piece (MOQ)
Tower Light - 4*1000W Winch - Manual Outriggers - 4 Fuel Tank Capacity in Lits - 45 Spark Arresters - Nil Lifting Eyes - 9 Meter Dry weight in Kgs - 875 Operating Weight in Kgs - 920 Mast Stowed (LXWXH) without light & its bracket in mm - 4200*1400*1550 Mast Stowed (LXWXH) with light & its bracket in mm - 4400*1600*1700 Engine Make - Mitsubishi Model - MVL3E-63 JGSB Cooling - Liquid Aspiration - NA No. of Cylinders - 3 RPM - 1500 Compression Ratio - 23:01 Bore Stroke(mm) - 76*70 Cubic Capacity(Its) - 0.952 Power(HP) - 9.4 Governing* - Mechanical Starting System - 12V Electrical Lube Oil Specification - SAE 20/40 Lube Oil Sump Capacity in lIts - 4.7 Fuel Consumption on Lighting per Hrs - 1.5 Fuel Consumption on Aux Power Drop per Hrs - 1.2 Fuel Consumption on both Lighting & Aux Power per Hrs - 2.6 Fuel Consumption on 75 % load per Hrs - 2 Max Operating ambient temp - 0- 45 Degree Celsius Generator Make - Lerry Somer Model - LSAP 40 C1 Power Rating(KVA/KW) - 7 KVA/5.6 KW No. of Phases - 1 Power factors - 0.8 Current@0.8(Amps) - 28.7 Amps Battery Rating - 12V-65AH Alternator - 7KVA Voltage - 240 Frequency - 50 Voltage Regulation (max.) - ± 1% Insulation - Class H Enclosure - IP23 Lights Lumens - 4,20,000 Protection - IP55 Type - Metal Halide Auxiliary Power Power Out - 1.6 Kw Running Gear Tyre size - 185/70-R14 Max Hub/ Axial Rating Capacity - 1530 Kg Max Towing Speed - 40 KM/HR Sound Level - 70 Dba Mast Rotation - 0 TO 355 degree ADVANTAGES Fuel tank is easily removable at the time of engine and alternator service. Usage of derlin sheet to reduce the friction between the sliding towers. Better structural design for tower rest. Compact control panel design. Silencer exhaust is provided near the bottom of canopy to avoid hot air exhaust direct to the operating person. Tower self lock is available at vertical position to reduce the roop stress Jack height from floor level is 10 inch while other suppliers are using 6 inch jack only. Cost of Door hinges are less and easily available in market. Larger doors provide for better space and easy service. Engine safety is indicated by lamp. We provide voltmeter to measure voltage which is not available in other supplier Models We provide ammeter to measure amps which is not available in other supplier models. We provide door lock key to ensure the safety of Machines Easy and trouble free control panel. We provide identification marks for switches in each light. We provide knob lock for tower pivot it is easily handled. Usage of MCB switch trip Prevent the short circuit damege if any .
Application : Park, Sports Ground, Weddings
...moreDiesel Light Tower
300,000 - 350,000 Per Piece
Tower Light - 4*1000W Winch - Manual Outriggers - 4 Fuel Tank Capacity in Lits - 45 Spark Arresters - Nil Lifting Eyes - 9 Meter Dry weight in Kgs - 875 Operating Weight in Kgs - 920 Mast Stowed (LXWXH) without light & its bracket in mm - 4200*1400*1550 Mast Stowed (LXWXH) with light & its bracket in mm - 4400*1600*1700 Engine Make - Mitsubishi Model - MVL3E-63 JGSB Cooling - Liquid Aspiration - NA No. of Cylinders - 3 RPM - 1500 Compression Ratio - 23:01 Bore Stroke(mm) - 76*70 Cubic Capacity(Its) - 0.952 Power(HP) - 9.4 Governing* - Mechanical Starting System - 12V Electrical Lube Oil Specification - SAE 20/40 Lube Oil Sump Capacity in lIts - 4.7 Fuel Consumption on Lighting per Hrs - 1.5 Fuel Consumption on Aux Power Drop per Hrs - 1.2 Fuel Consumption on both Lighting & Aux Power per Hrs - 2.6 Fuel Consumption on 75 % load per Hrs - 2 Max Operating ambient temp - 0- 45 Degree Celsius Generator Make - Lerry Somer Model - LSAP 40 C1 Power Rating(KVA/KW) - 7 KVA/5.6 KW No. of Phases - 1 Power factors - 0.8 Current@0.8(Amps) - 28.7 Amps Battery Rating - 12V-65AH Alternator - 7KVA Voltage - 240 Frequency - 50 Voltage Regulation (max.) - ± 1% Insulation - Class H Enclosure - IP23 Lights Lumens - 4,20,000 Protection - IP55 Type - Metal Halide Auxiliary Power Power Out - 1.6 Kw Running Gear Tyre size - 185/70-R14 Max Hub/ Axial Rating Capacity - 1530 Kg Max Towing Speed - 40 KM/HR Sound Level - 70 Dba Mast Rotation - 0 TO 355 degree ADVANTAGES Fuel tank is easily removable at the time of engine and alternator service. Usage of derlin sheet to reduce the friction between the sliding towers. Better structural design for tower rest. Compact control panel design. Silencer exhaust is provided near the bottom of canopy to avoid hot air exhaust direct to the operating person. Tower self lock is available at vertical position to reduce the roop stress Jack height from floor level is 10 inch while other suppliers are using 6 inch jack only. Cost of Door hinges are less and easily available in market. Larger doors provide for better space and easy service. Engine safety is indicated by lamp. We provide voltmeter to measure voltage which is not available in other supplier Models We provide ammeter to measure amps which is not available in other supplier models. We provide door lock key to ensure the safety of Machines Easy and trouble free control panel. We provide identification marks for switches in each light. We provide knob lock for tower pivot it is easily handled. Usage of MCB switch trip Prevent the short circuit damege if any .
Application : Park, Sports Ground, Weddings
...moreBe first to Rate
Rate ThisOpening Hours
We, Sunbeam Generators are renowned as one of the manufacturers and leading suppliers of Mobile Lighting Towers. With our advanced approach, we can suppose the ever-changing market supplies and deliver products that are following the exact requirements of clients. We have been at the front of the industry by using innovative engineering ideas and the newest technology.
Our establishment
Established in the year 1996 we are a renowned name in the market offering premium quality lightening towers like LT 1000 Light Tower, LT-400 Light Tower, Diesel Light Tower, Portable Light Tower etc. created a reliable and firm position in this business domain. We have the ability in supplying industrial uses trade and other machines.
Our quality policy
Our team of specialists keep a firm vigil on the whole obtaining procedure that allows us to deliver quality products. We also have complete testing facilities that authorize us to guarantee the performance and service life of our lightning towers. We continually endeavor to offer our customers with seamless range along with actual after-sales service
Why us?
Supplying best quality products
Tried and tested products
Offering multiple ranges of products
Safe and secure packaging
Able to deliver anywhere in the country
Transparent pricing policy
Reliable after-sales services