Power Transformers
4,000 Per Piece
10 nos (MOQ)
Power Transformer
Dry Type Transformer
Get Price Quote
Leveraging upon our experienced team of professionals, we are able to offer a gamut of Dry Type Transformer. The offered range of transformers offers high efficiency up to 200 KVA and is manufactured using premium quality lamination and electrolytic grade super enameled/DFGC copper wire. Additionally, we provide the entire range of products in various technical specifications, as per the ever-evolving requirement of our clients. Features: Excellent voltage regulation High performance Durable frequency
Best Deals from ABB Distribution Transformer
Power Transformers
Get Price Quote
Single Phase Transformer We are Leading Manufacturer and Supplier of Power Transformers such as Single Phase Transformer
Distribution Transformers
Get Price Quote
Distribution Transformers It is the transformer which brings final voltage down and distributes the electrical power to the power lines through distribution poles. It helps the electricity to reach our home. This kind of power distribution requires various transformers with different sizes and proficiencies. So People select as per their budget and requirements.
Distribution Transformers
Get Price Quote
Lamco Transformers Pvt. Ltd. is a prominent manufacturer and supplier of distribution transformers that are specifically used for converting and distributing electrical energy with high voltage to lower voltages. This distribution transformer is made at ultra-modern unit using the premium quality components and advanced technology in conformance with defined quality standards. We are consistently manufacturing high quality distribution transformer at affordable prices. Ranging From 25KVA, 63KVA, 100KVA, 200KVA, Upto 1MVA For Line Voltage 11kv, 22kv and 33kv.
Power Transformers
Get Price Quote
Power Transformers
Get Price Quote
Our products have the largest satisfied customer base. Dedicated to providing environment friendly quality solutions and commitment to delight customers with unique value propositions.
Distribution Transformers
Get Price Quote
Distribution Transformers usually use copper or aluminum conductors and are wound around a magnetic core to transform current from one voltage to another. Distribution transformers come in two types; dry-type and liquid. The Distribution Transformers are usually smaller and do not generate much heat and can be located in a confined space at a customer's location. The liquid type usually have oil which surrounds the transformer core and conductors to cool and electrically insulate the transformer (see also Oil Filled Transformers). The liquid distribution transformer types are usually the larger and need more than air to keep them from overheating thus the oil insulator. Distribution transformers can vary in size, with the most common ranging in size from 5 KVA single phase to 2500 KVA. They come in single phase and three phase and can be pad mounted or pole mounted. The three phase Distribution transformers are used with an underground primary circuit and three single-phase pole type transformers for overhead service. Where large concentrations of businesses or large cities they are usually installed in an underground vault. Power is then sent via underground cables to each customer. One of the main advantages of distribution transformers are that they can usually withstand overloads.
Current Transformer
Get Price Quote
Starlit Electricals is counted among the leading manufacturers of Current Transformers that are broadly used to produce electric current. We manufacture a comprehensive range of standard C.Trs. There are following types and subtypes of Current Transformers. 1) L.T Tape wound/Cast Resin type CT. i. Ring/window type and ii. Wound primary type 2) L.T/ H.T Cast Resin CT. i. Ring/window type and ii. Wound primary upto 33 KV with Indoor/ Outdoor application. 3) H.T Indoor / Outdoor Oil Immersed type C.T/ P.T upto 66KV. Function of Current Transformer The main function of the Current Transformer is to reproduce the Primary current on its secondary side. The Current Transformer isolates the devices connected to their secondary circuit from the network system. Current Transformers are specially designed for measuring and protection applications. Standard Terminology used for CT: Rated primary current: The Current to be measured and transformed to lower value Rated secondary current: The current on the secondary side of the CT Typical values of secondary current are 1A or 5A. For WTI Current Transformers 3 A secondary current is also specified. For special differential protection, secondary currents of 1/ Rt 3 A and 5/ Rt 3 A are also specified. Accuracy class: For metering CT s, accuracy class is typically 0.2, 0.5,1 or 3. This means that the errors have to be within the limits specified in the standards for that particular accuracy class. The metering CT has to be accurate from 5% to 120% of the rated primary current at the specified power factor. Class PS/ PXCT: In balance systems of protection, CT s with a high degree of similarity in their characteristics is required. These requirements are met by Class PS /PX CT s. Their performance is defined in terms of a knee-point voltage (KPV), the magnetizing current (Imag) at the knee point voltage or 1/2 or 1/4 the knee-point voltage, and the resistance of the CT secondary winding corrected to 75C. Accuracy is defined in terms of the turn’s ratio. Knee point voltage: That point on the magnetizing curve where an increase of 10% in the flux density (voltage) causes an increase of 50% in the magnetizing force (current). Exciting Current: The current measured in mA@ Knee point Voltage Secondary Resistance: The secondary resistance of C.Tr generally measured @ 75 deg C. A General table indicating the Application of Tests A number of routine and type tests have to be conducted on CT s before they can meet the standards specified above. The tests can be classified as: Accuracy tests to determine whether the errors of the CT are within specified limits. Composite Error Test: To verify whether the Trs comply with the accuracy limit factor indicated on the nameplate Knee Point Voltage Test: To verify that the knee point is equal to or greater than the knee point indicated on the nameplate Inter turn insulation Test: To check the insulation between winding Dielectric insulation tests such as power frequency withstand voltage test on primary and secondary windings for one minute, Impulse tests with 1.2u/50 wave, Temperature rise tests. Short time current tests Verification of terminal markings and polarity. The routine tests are carried out in the test lab located in our factory premises itself. The type tests are conducted at NABL accredited labs such as ERDA or CPRI located in India.
Power Transformers
Get Price Quote
We are the main supplier of this product.
Current Transformer
350 Per Units
Current Transformer
190 Per Piece
100 Piece (MOQ)
Power Transformers
Get Price Quote
No Load losses minimized by using CRGO steel. The Core assembly of step lap construction has minimum losses. Core is tightly pressed and bound by glass reinforced resin tapes. Proper insulation is provided between clamping channels and the entire assembly is insulated from tank by insulating packing. Prime CRGO lamination is used. Cut and assembled to achieve a near perfect-circle core cross section, resulting in the efficient use of materials plus a lighter, more compact, high performance transformer Welding process produces deep penetration welds, virtually eliminating leakage from welded tank joints. Inside tank surfaces are sand blasted and painted with heat resistant paint. Transformer exterior coated to a minimum thickness of 3 mils; this coating has superior endurance characteristics. Detachable radiators with/without fansPressed and vacuum treated coils. Welding process produces deep penetration welds, virtually eliminating leakage from welded tank joints. Inside tank surfaces are sand blasted and painted with heat resistant paint. Transformer exterior coated to a minimum thickness of 3 mils; this coating has superior endurance characteristics. Detachable radiators with/without fansPressed and vacuum treated coils of prime quality are used and duly pressure tested. OLTCs and OCTCs are of Easun MR/CTR. Recently for an export order, dry type OLTCs were used.the right of this text. Key Customers • Steel industries• Sugar Factories• Auto Industries• Military engineering services• All HV & EHV consumers• State electricity boards• Co-genertion plants
Distribution Transformers
Get Price Quote
We are counted among the top companies, which are engaged in supplying Distribution Transformers from Maharashtra, India. We come up with well-tested Distribution Transformers that deliver optimum performance. When it comes to packing Distribution Transformers, we use high quality packaging material that ensures their safety during transit. One can place retail as well as bulk orders for Distribution Transformers with us.
Distribution Transformers
Get Price Quote
We have specialized in manufacturing optimum quality distribution transformers. The distribution transformers offered by us are capable of handling 2000kva and 33kv range. Designed by experts, these distribution transformers are made following is standards meeting specifications laid by tata electricity board. We can also produce distribution transformers as per specifications laid by the clients.
Power Transformers
Get Price Quote
(for Power applications except Distribution Transformers):-HIGH VOLTAGE transformers used in equipment's requiring very high secondary power rating of upto 10 KV Designs can be customized upto 300 kVA (Standard designs available in 25, 50, 100, 200 KVA) Copper or Aluminum winding Rectangular or step core designs
Current Transformer
Get Price Quote
Electrical Cable, Extension Roller, Nylon Cable Tie, Cable Ties
Transformer
Get Price Quote
Transformer, Cable Termination
Power Transformers
Get Price Quote
transformer repair services, Flameproof Lighting, prepaid meter
Current Transformer
21 - 50 Per piece
r core transformer, EDR25, 20 transformer, EE4215