Ampcontrol Equipments Pvt. Ltd. Chakan, Pune, Maharashtra

  • starting resistors

    starting resistors

    Request for Price

    Manufacturer & Exporter of Starting Resistors. Our product range also comprises of Load Banks and Braking Resistors.   Features : This resistor allows a stepped starting having high starting torque with low and limited starting currents. Suggested for high power motors and to drive equipments with strong inertia and needs of fast accelerations and heavy, long and frequent startings This resistor is used for gradual starting with the possibility to choose the torque in relation with the device to start. Suggested for equipments with low starting torque and increasing advancement

    ...more
    Get Best Price
  • resistive load banks

    resistive load banks

    Request for Price

    Get Best Price
  • Steel Neutral Isolator Panels

    Steel Neutral Isolator Panels

    Request for Price

    We are engaged in offering of Neutral Isolator Panels for Steel Industries. Quality being our priority, we send all our products through a number of quality checks. Features: Vibration Test Rain Test Hygroscopic Test HT indoor isolators of following rating 3.3 KV / 6.6 KV/ 12 KV / 22 KV / 33 KV     400 Amp./630 Amp./1200 Amp./1800 Amp./3200 Amp 

    ...more
    Get Best Price
  • nis panels

    nis panels

    Request for Price

    manufacturer & exporter of nis panels & neutral isolator panels. Our product range also comprises of load banks, starting resistors and braking resistors. features : in electric braking, traction motor acts as a generator. Kinetic energy of a moving train converted into electrical energy is, dissipated in the form of heat. This is called dynamic braking. construction : dynamic braking resistors are manufactured as per customers requirement. testing : all routine tests are conducted in-house. following special tests are also conducted if required: vibration test • rain test • hygroscopic test. • isolators • ht indoor isolators of following rating • 3.3 kv / 6.6 kv/ 12 kv / 22 kv / 33 kv. • 400 amp./630 amp./1200 amp./1800 amp./3200 amp. owing to the high level of performance and sturdy construction, these neutral isolator panels manufactured and supplied by us are one of the highly preferred products in the market. This product is one of the most common, reliable, economical, and efficient solutions for earthing. This product is manufactured using high quality raw materials and modern machinery, under the supervision of trained and experienced professionals. Quality being our priority, we send all our products through a number of quality checks. testing :  all routine tests are conducted in-house following special tests are also conducted if required : vibration test rain test hygroscopic test

    ...more
    Get Best Price
  • ngtr panels

    ngtr panels

    Request for Price

    Features : NGTR Panel/ Cubicle encloses Neutral Grounding Transformer (NGT) and Neutral Grounding Resistor (NGR) for grounding/ earthing of Neutral current during unbalanced three phase load of the generator. This is essentially required for protection of the generator. Neutral Grounding Transformer (NGT) steps down the voltage of neutral bus from 6.6 KV/ 11 KV/ 15.75 KV level to 110 Volt or 220 Volt level. This stepped down voltage is connected to a netral grounding resistance and a ground earth terminal fro bringing the voltage level of neutral bus as close as possible to zero voltage level Manufactured using high quality raw materials, we offer these Neutral Grounding Transformer Resistor Panels. Being processed through a number of quality checks, these products supplied by us are known for their sturdiness and durability. We are one of the leading manufacturers of these products, and we believe quality to be our priority. This product is known for the protection it provides to the generators from an unbalanced, three phase load. These products are made available in the market at very competitive prices, increasing their demand.   Rated Voltage : For neutral grounding or earthing resistor rated voltage means line- to neutral voltage i.e. System Voltage divided by root 3 i.e. 1.732 Rated Current : Means Initial current that will flow through resistor when it is cold. Normally Full load current value is same as Rated current Time Rating : It is length of time for which NGR must tolerate rated voltage Short Time Rating : Normally it is 10 sec. or 30 sec. or 60 sec. depending on design parameters of protection system Continuous Rating : It is normally 10 % of full load current for healthy system neutral grounding resistor to be designed for continuous rating of 5 % to 10 % of full load current Temperature Rise Allowed: Normally Temperature rise is restricted to 375 deg.c. above ambient temperature as per BS-587 Cabling or termination : Suitable arrangement and clearance is provided for termination of cable, flats or bus duct as per requirement with removable gland plate Construction: NGR include resistor assembly, plus required insulators, internal connections and hardware etc Material of Resistance Element: We offer resistor elements made from any stainless steel or Cu-Ni or Ni-Cr or any other resistance material as per requirement. Normally formed stainless steel element are best and economical for NGRS

    ...more
    Get Best Price
  • Neutral Grounding Resistors

    Neutral Grounding Resistors

    Request for Price

    features : neutral grounding resistors are used in star connected systems to protect the transformer / alternator from severe damage caused in event of an earth fault. we manufacture neutral grounding resistors for all current ratings upto 3000a and for a voltage range from 230v to 36kv. the resistors can be designed in cast iron grid, rod formed grid, wire wound and punched grid form. advantages of using a neutral grounding resistor: • reduced operation and • maintenance expenses. • fast isolation of the original fault. • reduced transient over voltages. • reduced physical damage on the • equipment at fault. • simplification of ground fault location. • increased life and protection of • transformers, generators and • related equipment. • reduced frequency of faults. • improved service reliability. • increased protection in the use of lightning arresters. • increased safety for personnel.

    ...more
    Get Best Price
  • Load Banks for Industrial Automation

    Load Banks for Industrial Automation

    Request for Price

      We are engaged in offering of Load Banks for Industrial Automation. Known for its compact structure and high level of efficiency, Load Banks are highly appreciated in the market. What Is Load Bank : Load banks are compact units that are coupled to the output of your power generation system such as diesel generators, gas turbines or UPS and battery systems Load banks are dummy loads, designed to simulate the plant load and prove the design, performance and the capacity of the system, without interruption to the normal running of your plant WHAT DOES A LOAD BANK DO : Generators are usually rated to supply sufficient power to a plant or building, based on the maximum demand required. Sufficient plant loading is not always available to safely load generators. Under loading of the engine will cause a high wear rate due to insufficient fuel combustion and loss of lubrication resulting in cylinder bore glazing and fouling of exhaust ports and valves. Running the generator without load will not prove its performance or power capacity. Proper and controlled loading is therefore essential. It increases diesel engine life by up to four times and improves the efficiency by ensuring that the engine has sufficient loading at all times. It proves the rated power, proves system operation, controls integrity and communications of your power system. It maximize battery life in UPS systems by regular loading and discharging. Specifications : Power ratings available : 1KW / 2KW / 5 KW / 10KW Voltage Primary : 440V AC 3Phase/ 220V AC Single phase /220V DC Enclosed in cabinet with Steps provided for loading, meters provided for each phase & terminations brought out on Banana terminals

    ...more
    Get Best Price
  • Load Banks

    Load Banks

    Request for Price

    Voltage utilized in industry are of either resistive, inductive or capacitive types these provide various types of power factor and the power system behaves accordingly. Resistive load banks are used to provide braking effect or for heat dissipation. These have canthel wires wounded on porcelain tubes through which electricity is passed & current flows, normally for resistive loads the power factor is unity. This model is the industrialeducational model suitable for demonstrating to students the complete know of the basics, loading provided in steps, study of efficiency & maintenance of these loads packaged in small rating. Students can make connections of their own with the help of the terminations provided

    ...more
    Get Best Price
  • LAVT Panels for Hydro Power Industries

    LAVT Panels for Hydro Power Industries

    Request for Price

    We are offering a wide range of LAVT Panels for Hydro Power Industries. With its shock proof body and strong built, theseLAVT Panels manufactured and supplied by us are known for the long operational life. Advantages of using : Installation of NGR in the system reduces mechanical stresses in circuits and equipment subjected to fault currents. This also reduces the electrical-shock hazards to personnel caused by stray ground fault currents in the ground return path Reduction in the momentary line-voltage dip occasioned by the occurrence and clearing of a ground fault To secure control of transient over-voltages while at the same time avoiding the shutdown of a facility circuit on the occurrence of the first ground fault Installation of NGR protects critical and expensive equipment such as Transformers and Generators from damage due to earth faults Specifications : Power Rate: 11 KV Upto 24 KV system Materiel - Surge Capacitor, Surge Arrester Voltage Stroke Potential transfer

    ...more
    Get Best Price
  • Lapt Panel Boards

    Lapt Panel Boards

    Request for Price

    Features : WE HAVE EMERGED AS ONE OF THE TRUSTED ORGANIZATION ENGAGED IN FABRICATING LAPT PANEL BOARDS TO THE CUSTOMERS. OUR RANGE IS WIDELY APPRECIATED BY THE CLIENTS FOR ITS EFFICIENT FUNCTIONING AND APPLICATION IN VARIED INDUSTRIES & SECTORS. MOREOVER, WE CONSIDER THE MARKET DEMAND WHILE FABRICATING THESE PANELS. FOLLOWING ARE THE FEATURES OF THESE PRODUCTS : • Shock-proof exteriors • Sturdy construction • Reliable performance   An LAVT panel is a cubicle which houses a Lightning Arrester (Surge Arrester), Surge Capacitor, and Voltage / Potential Transformers for a Phase Isolated Bus Duct. Lightning arrestor is there to provide protection against any surges in voltage, hence the name lightning arrestor, it is a device that safely diverts any surge in voltage "away" from your plant therefore protecting your equipment against overvoltage conditions. A capacitor is connected in parallel with the lightning arrester for enhanced protection as well. The voltage transformer will probably be for either protection purposes or for some instruments on your system.If you have a voltmeter or wattmeter etc on the panel then it is probable that it's supply is derived from the VT. A VT transforms the primary voltage, in this case 11kV down to a low voltage (probably 110V) to give an accurate representation of the system volts, which can be incorporated into protection devices and measuring devices. LAVT Panels are used in all high voltage power Plants wherein for protection of the Alternator. This unit is phase isolated and is mostly connected to the bus duct.

    Voltage : 110V

    Country of Origin : India

    ...more
    Get Best Price
  • inductive load banks

    inductive load banks

    Request for Price

    Get Best Price
  • high resistivity power resistors

    high resistivity power resistors

    Request for Price

    We are offering high resistivity power resistors

    Get Best Price
  • Electrical Heaters

    Electrical Heaters

    Request for Price

    Manufacturer & Exporter of Electrical Heaters. Our product range also comprises of Load Banks, Starting Resistors and Braking Resistors. Features : The comprehensive range of electric heaters offered by us is manufactured in compliance with the international quality standards We are one of the most well known manufacturers and suppliers of these Electrical Heaters. Manufactured in accordance to international standards and norms, the production process involves using of high quality raw materials and processing the end products through a number of quality checks. These products are known for the efficient heating it provides. This product is highly demanded in the market owing to its high quality and low pricing. Detail : No Thermostat required,virtually unlimited life, it can control the temperature by itself safety due to automatic temperature control it depends on PTC elements as its heating resources Doesn't burn when in contact with paper, matches or clothes No moving parts to wear, Very low cost No electrical noise, the higher temperature, the more electricity efficient Low electricity consumption, efficient heat retaining

    ...more
    Get Best Price
  • Braking Resistors

    Braking Resistors

    Request for Price

    When an induction motor’s rotor is turning slower than the synchronous speed set by the drive’s output power, the motor is transforming electrical energy obtained from the drive into mechanical energy available at the drive shaft of the motor. This process is referred to as motoring. When the rotor is turning faster than the synchronous speed set by the drive’s output power, the motor is transforming mechanical energy available at the drive shaft of the motor into electrical energy that can be transferred back to the drive. This process is referred to as regeneration. Most AC PWM drives convert AC power from the fixed frequency utility grid into DC power by means of a diode rectifier bridge or controlled SCR bridge before it is inverted into variable frequency AC power. Diode and SCR bridges are cost effective, but can only handle power in the motoring direction. Therefore, if the motor is regenerating, the bridge cannot conduct the necessary negative DC current, the DC bus voltage will increase and cause an overvoltage fault at the drive. More complex bridge configurations use SCRs or transistors that can transform DC regenerative electrical power into fixed frequency utility electrical energy. This process is known as line regeneration. A more cost effective solution can be provided by allowing the drive to feed the regenerated electrical power to a resistor which transforms it into thermal energy. This process is referred to as dynamic braking.

    ...more
    Get Best Price
  • low resistance power resistors

    low resistance power resistors

    Request for Price

    Get Best Price
  • temperature coefficient power resistors

    temperature coefficient power resistors

    Request for Price

    Get Best Price
  • corrosion resistance power resistors

    corrosion resistance power resistors

    Request for Price

    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Manufacturers
  • Secondary Business Type Exporters / Wholesale Suppliers

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
AMPCONTROL was formed in 1995 with the backing of over 25 years of experience that its promoters have gained in design and manufacture of various type of resistors.
Today Ampcontrol is one of the leading manufacturers of Power Resistors in India. We are capable of designing and manufacturing all types of electrical resistor with various combinations of punched, formed and wire wound type for all ratings.
A comprehensive quality assurance plan and adherence to international specifications ensures a durable competitively priced product which meets the customer requirements.
Apart from designing complex resistors, positive feedback from customers & our growing list of clients add to our strength and confidence in our field.
Read More »

Contact Information

Ampcontrol Equipments Pvt. Ltd.

  • Mr.. Chetaniya/ C. N. Ghate
  • Gat No. 153 / 5 / 1 / 2, Mahalunge Ingale, Chakan-Talegaon Road, Tal.: Khed, Dist. Pune - 410501, Maharashtra.

Find Popular Electrical Resistance Heater Dealers in Pune

top