Analytical Instruments Dealers in Aundh, Pune

(12 products available)
  • On line Automatic Water Hardness Monitor

    On line Automatic Water Hardness Monitor

    Get Price Quote

    The PL101 Hardness Monitor continuously analyzes water from Softener output line to detect crossing of pre-set Hardness limit in water. It gives an audio-visual alarm when Hardness level exceeds the pre-set Hardness limit. This signal can actuate Softener regeneration or stop flow of hard water to utility equipment, such as boiler. Also, the test interval is user-selectable from 1- 99 minutes and instant test can also be performed at the push of a button.  

    more..
  • PH INDICATORS / PH TRANSMITTERS

    PH INDICATORS / PH TRANSMITTERS

    Get Price Quote

    GENERAL DESCRIPTION Analogik PH meter and transmitter incorporates the latest high technological advancements. It has very stability, reproducibility & contineous duly cycle. The instrument having very high input impedance advanced (MOS-FET butter OP-AMP) The instrument accepts all types of PH electrode. Auto / manual temp, compensation facility is available. The instrument indicates PH by 3 1/2 digit LED / LCD display. FEATURES Manual / Auto temp, compensation by pt-100 sensor. Direct indication of PH/ mV and temp, by LED/LCD displays. Slope control for correcting electrode slope. Asymetry control to eliminate ageing offect. 0 / 4 to 20 mA output into 500 V incase of PH transmitter. CONSTRUCTION & OPERATION The glass epory, green masked, PCB with high quality components soldered gives the drift free performance. The mV signal from PH electrode is directly given to high I / P impedance buffer amplifier and then this signal is processed. The auto/manual temp, compensation circuit is added at this stage & signal is given to DPM / V to I connector. Thus we get PH indication or 0 / 4 to 20 mA signal proportional to input pH. APPLICATIONS pH meter and PH transmitter are commonly used in many industries & plants. Used in water treatment plants, Power Station, Sugar Mills, Steel Plant, Paper Industry, Chemical, Petro Chemical, Food, Fertiliser, Soft Drink Industries. SPECIFICATIONS pH INDICATOR pH TRANSMITTER RANGE O to 14H. 1999 mV Oto14PH. DISPLAY OUTPUT 3 1/2 digit LED or LCD 3 1/2 digit LCD-local indication optiona 0/4 to 20mA proportional to 0 to 14 PH. ACCURACY 0.25% of F. S. 0.25% of F. S. TEMP.Compensation Automatic with pt -100 manual by pot Oto130°C. 0 to 130 °C. Automatic only. INPUT IMPEDANCE SUPPLY >1012Ohms. 9 VDC, 230 V AC, 50 Hz 1 PHASE >1012Ohms. 9 VDC, 230 V AC, 50 Hz 1 PHASE SLOPE ADJUSTMENT 90 to 110% at 25 °C. 1 90 to 110% at 25 °C. 1 ASYMETRY ADJUSTMENT 1 PH. 1 PH. OUTPUT LOAD - 500 V Max. RECORDER OUTPT  

    more..
  • Best Deals from Analytical Instruments

  • Particle Image Velocimetry

    Particle Image Velocimetry

    Get Price Quote

    • Features: High power LED Volume or light sheet Synchronization PIVTecILA software Easy setup Background illumination ILA.PIV.Nano Camera Also suited for MicroPIV Etc
    • Specifications: Pulses 0...200A Power 0...47mW/ cm2 Colours green, blue, red, white, UV Length 120mm (without op

    Particle Image Velocimetry is a non-intrusive laser optical technique used for determination of the velocity distribution in fluids. The complexity of a system can strongly vary depending on the type of application, however the basic principle of PIV stays the same. For the purpose of PIV, the fluid is seeded with light scattering particles, which are believed to follow the flow dynamics. The flow is illuminated by a concentrated light source, normally a laser, where as a special camera is acquiring the reflected light from tiny particles in the flow. The camera takes two consecutive images which are synchronized with the two light pulses. The light pulse is very short such that single particles can be identified in the images without blurring effects. The cross correlation software then calculates the displacement of the particles between the first and second image. Since the time between the two light pulses is known, the velocity field can be calculated.

    more..
  • Blood Gas Analyzer

    Blood Gas Analyzer

    1,000,000 Per Piece

    • Instrument Name: Biochemistry Analyzer
    • Application: Hospital
    • User Input: Touch
    • Brand Name: OPTI Medical
    • Dimensions: 124 x 362 x 230 mm (4.7 x 14.2 x 9.1 in)
    • Weight: 5.5 kg (12 lb)
    • Display: Digital
    • Model: OPTI CCA-TS
    • Voltage/Frequency: 120 or 240 AC, 50–60 Hz
    • Power Consumption (max.): 110 VA
    • Operating Temperature: 10–32°C (50–90°F)
    • Sample Volume: 125 µL (60µL for B60 cassette)
    more..
  • Power Quality Analyzer

    Power Quality Analyzer

    Get Price Quote

    The UMG 511 power quality analyser is particularly suitable for monitoring power quality according to standards such as the EN 50160. All power quality parameters are collected and analysed e.g. flicker, short term interruptions with fault recorder function, transients, harmonics up to the 63rd and inrush currents etc. Extensive communication possibilities e.g. RS 485 Modbus, Profibus, Ethernet (TCP/IP), BACnet, http, FTP, SMTP, SNTP, DNS ... allow cost effective and rapid integration in existing communication networks. Worldwide access to the embedded web server can be gained through a web browser. The GridVis software included in the content of delivery allows extensive analysis just by the click of a button.

    more..
  • Particle Size Analyser (PSA)

    Particle Size Analyser (PSA)

    Get Price Quote

    • Benefits: Real-time analysis,High accuracy, measuring up to microns etc.

    Particle size can influence the processability of powders, both API and excipient, and affect the final formulation. In order to maintain uniformity and obtain maximum efficacy from product, particle size distributions need to be studied, with quality control at key stages in production. The PSA is a powerful tool for research and development and quality control, determining size promptly, accurately and conveniently.

    more..
  • protein analyzer

    protein analyzer

    235,000 Per Piece

    1 Piece (MOQ)

    • Weight: 7.5 kg
    • Battery Back: 30 min
    • Memory: 1000 Patient
    • Sample Size: 80 ul
    • Display: Digital
    • Analysis Principle: Dual Test Method Nephelometry & Photometr y
    • Usage/Application: Laboratory Use
    • Model Name/Number: Mispa I3
    more..
  • Flue Gas Analyzer

    Flue Gas Analyzer

    67,000 - 67,909 Per Piece

    • Storage temperature: -20 to +50 C
    • Operating temperature: -5 to +45 C
    • Power supply Battery: 1500 mAh, mains unit 5V/1A
    • Display: Backlit 2-line display
    • Weight with probe: Approx 700 g
    • Dimensions: 201 x 83 x 44 mm
    more..
  • Carbon Silicon Analyser

    Carbon Silicon Analyser

    Get Price Quote

    This Controller Specially Designed To Measure %CE, %C & %SI For CI SG MALLEABLE Iron And Temperature Of Molten Metal, Also Controller having inbuilt Peak Temperature Indicator.

    more..
  • vibration analyzer

    Get Price Quote

    vibration analyzer, Field Balancing Machines, Dynamic Balancers

    more..
  • gas leak analyzers

    Get Price Quote

    gas leak analyzers, refrigerant leak detector

    more..
  • Analytical Instruments

    Get Price Quote

    Automatic back flushing filters

    more..
Filter by Locality
top