Belden Modbus Communication Cable
98 Per Meter
data communication cables
Get Price Quote
Application :- These are special PVC data cables used for flexible use with free movement without tensile stress of forced movements in dry, moist and wet rooms but not suitable for open air, wherever the construction requirements call for a minimum outer diameter. Technical Data :- Standard : Based on VDE 0812 Nominal Voltage : 0.14 mm² = 350 V; >/= 0.25 mm² = 500 V Insulation Resistance : Min. 20 GΩ x cm Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C Minimum Bending Radius : For flexible use 10 x cable ø Test Voltage : Up to 0.25 mm² = 1200 V. From 0.34 mm² = 2000 V Breakdown Voltage : Up to 0.25 mm² = 2400 V. From 0.34 mm² = 4000 V Cable Construction :- Bare copper, fine wire conductors, bunch stranded DIN VDE 0295 cl. 5, EN 60228 cl. 5. Special PVC core insulation TI2, to EN 50363-3. Conductor make-up for 0.14 mm² = 8 x 0.10 mm., 0.25 mm² = 14 x 0.15 mm., 0.34 mm² = 19 x 0.15 mm. Core colours as per DIN 47100. Cores stranded in layers with short lay-length. Special PVC outer sheath TM2, to EN 50363-4.1. Colour grey (RAL 7032).
Best Deals from Communication Cable
BLDC Motor Communication Cable
200 Per Piece
10 Piece (MOQ)
HMI Communication Cable
750 Per Meter
1 Meter (MOQ)
EIB Bus Cable
53 Per Meter
PLC Programming Communication Cables
3,450 Per Piece
Plc Communication Cable
2,500 Per Meter
data communication cables
Get Price Quote
At Elcab we manufacture various types of communication cables that are used in 2G and 3G networking. Brand: Elcab Conductors Detailed Description We also manufacture various control,instrumentation and power cables that are used in setting up of telecommunication grids worldwide. For more details feel free to write to us.
Copper Communication Cables
Get Price Quote
Parameters conductor Size (mm) 0.4 0.5 0.63 0.9 conductor Resistance (per Km in Ohms.) individual 135 ± 8 86 ± 6 58 ± 4 28 ± 2 conductor Resistance Unbalance (%) individual 3 2.5 2 2 average 1.5 1 1 1 conductor Elongation (minimum %) 15 15 18 18 attenuation At 150 Khz (db/km) Shall Not Exceed 12 8.25 6.3 4.4 insulation Solid (mdpe/hdpe) spark Test 3 Kv Rms Ac, 1 Spark per 5 K.m. retraction of Insulation (shall Not Exceed) 2.5 Mm After 1 Min resistance to Compression 200 N, 12 V Dc insulation Resistance At 500v5000 Mega Ohm – Km construction 10/20 Pair Units & 50/100 Pair Super Units of Sizes: 10 Pair to 2400 Pairs filling Compound water Resistant Compound (petro Jelly) core polyester Tape moisture Barrier Poly – Aluminium sheath / Jacket Ldpe armouring Galvanised Steel Tape armouring Bedding Pe Tape mutual Capacitance (nf/km) individual 52 ± 4.5 average 52 ± 3 capacitance Unbalance (pf/km) individual 3000 Pf average 750 Pf far End Cross Talk (db) At 150 Khz, Better Than 67.8 Rms Indvl. 55 Rms near End Cross Talk (db) At 150 Khz better Than 55 Rms (individual Value) pairs from 5 Pairs to 2400 Pairs.
communications cable
Get Price Quote
communications cable, Jelly Filled Telephone Cable, Router, telecom products
communications cables
Get Price Quote
communications cables, old transformer, Old Bulldozer & Cranes