(11 products available)
  • Two Bed Dm Plant

    Two Bed Dm Plant

    Get Price Quote

    We are offering two bed dm plant to the valued clients. Depending on raw water and treated water quality desired, the units in two bed dm plant get added for a specific purpose. customers can obtain the two bed dm plants at market leading rates. .

    more..
  • Water Filtration Plant

    Water Filtration Plant

    95,000 Per Piece

    • Capacity: 250-500 Ltr per hour
    • Material: Stainless Steel
    • Brand Name: Mintech
    • Power (Kilowatt): 4.9 kW
    • Frequency: 50-60Hz
    • Power Supply (V): 380V
    more..
  • Best Deals from Demineralisation Plants

  • Demineralized Water System

    Demineralized Water System

    Get Price Quote

    • Body Material: Mild Steel, Stainless Steel
    • Power: 0-3 Kw, 3-5 Kw
    • Power Source: Electric
    • Voltage: 220, 360 V
    • Control Type: Automatic, Semi Automatic
    • tank type: Vertical
    more..
  • Water Filtration Plant

    Water Filtration Plant

    Get Price Quote

    This plant is designed compact effluent treatment system. It is a complete system, which combines with sedimentation tank, and biochemical tank.

    more..
  • turbine oil filtration plant

    turbine oil filtration plant

    Get Price Quote

    We manufacture Oil filtration plants with varying capacities ranging from500 LPH to 10000 LPH. These plants are available as single stage and double stage variants depending upon the volume of insulating oil o be filtered. If higher capacity plants are required by the clients we can customize our plants to fulfill their requirements. The plants are also designed as mobile units besides the regular stationary unit. For outdoor usage they are supplied with and enclosure. The plant treats the unqualified turbine oil and removes the impurities from it to improve its quality. It efficiently removes water, gas and other impurities especially from emulsified turbine oil.   Features: Automatic systems with automatic advance system for safety, pressure, electricity and temperature constancy with infrared liquid- Has a trapezoidal, spiral, automatic back flushing system. Automatic Unmanned, On-line oil purification with turbine or water turbine Breaks emulsification thoroughly with high- molecule polymeric material Thoroughly clears the liquid water, free water and 80% dissolved water with effective dewatering with one and two step dehydration method Distinctive technique removes impurities by filtering through double FH trapezoidal network and absorbing by high polymer material Has the capacity to equal or surpass 200 and make the cleanness lower grade 6(NAS1638) with its advanced dielectric condensation devices.   This Vacuum Turbine Oil filter uses an advanced detaching theory of membrane which clears water and emulsification to purify the lubricant. The oil emulsifies to a much lesser degree after treatment. This TYA series prevent damage to the lubrication system and extends the life of both the insulating oil and the machinery.  

    more..
  • Oil Filtration Plant

    Oil Filtration Plant

    Get Price Quote

    OIL FILTRATION PLANTS CAN BE SUCCESSFULLY MODIFIED & AUTOMATED FOR VARIABLE FLOW RATE. A brief description is given for your reference.   INLET & OUTLET PUMPS : The pump will be driven by suitable sized AC drive to control the flow rate. By using these settings we can control the flow rate from i.e. If Plant is 6000 LPH then it will vary from 1000 LPH to 6000 LPH.   HEATER TANK : It is also necessary to select proper heat output for variable flow rates. This will avoid localized heating of oil for small flow rates.This section will incorporate PLC which will control the heaters.PLC will be used for control of heater groups, once certain flow rate has been selected, heaters will be configured automatically to suit that flow rate. This control panel will be designed for reliable & trouble free operation.By using the above system the major benefit is to have a single machine instead of different models for different capacities. In this case, flow rate can be kept variable from 1000 LPH to 6000 LPH. Power saving of 30% can be achievable by using this system as compared with traditional oil filter system designs.   OPERATIONAL & PROCESS AUTOMATION Press 'START' to start the oil filtration process. All airing valves, oil inlet & outlet valve will close. The rotary vacuum pump will start to achieve coarse vacuum. After achieving coarse vacuum level, which the 'Vacuum Switch' will sense. After achieve the desired level of fine vacuum in the plant, oil inlet valve & intermediate valve will open and the oil inflow will start due to vacuum inside the plant. The flow switch provided in the suction line of the plant will sense the oil flow & that signal will start the oil inlet pump. In case, the incoming oil flow is not there, HMI on the control panel will display 'LOSS OF OIL', with annunciation. One pressure release valve, provided across the inlet pump will control the excessive pressure rise in the plant. As oil is filled in the degassing chamber, the high level float switch will operate & that will put 'OFF' the inlet pump & start the outlet pump. The starting signal to the outlet pump will open the outlet valve. As the oil level in the degassing chamber comes down, the high level float switch will start the inlet pump, again. Thus the oil circulation through the filtration plant will start. After the continuous oil flow through the plant, the heaters will be 'ON'. Temperature of oil will be controlled by TIC (Temperature Indicating Controller) & one safety thermostat will control the accidental temperature rise. Thus the hot oil circulation through filters & degassing chamber will start resulting in the effective separation of solid impurities as well as dissolved moisture & gases from the oil. During the filtration process, the necessary interlocks provided will avoid malfunctioning of the plant, like   1. High level float switch will stop the inlet pump, to avoid flooding of the degassing chamber. 2. Unless the inlet pump is 'ON' the heaters will not be energized. 3. Low level float switch will stop the outlet pump to avoid dry running of the pump During the filtration process, the moisture meter, installed in the inlet line, will display the moisture content in PPM, continuously, on it's indicator, on the control panel. Once the desired PPM (moisture) content is achieved, the moisture meter installed in the inlet line, will shut down the plant, automatically. This plant will also run with Manual Interference means with Manual Operation.

    more..
  • Ultra Filtration Plants

    Ultra Filtration Plants

    Get Price Quote

    Ultra Filteration (UF) – Membrane Technology We make the Ultrafiltration Units of sizes and capacities from 500 LPH- 30,000 LPH as a modules.It is known fact about the Ultrafilteration that the porocity of 1.2mm-1.3mm dia Hollow fibers ( PES, PVDF ect.) is about 0.1 to 0.01 micron though there are membranes which ranges even lower than 0.01 microns. The uses of UF is mainly a part of Pre treatment  for the Down stream units of RO systems.The UF works on either Dead End or Cross flow type configuration and also as Out to In or In to Out type configuration.Probable application area in the water Purification is for removal of Bacteria/virus micro organisms, as well as the fine suspended particles such as color/dyes ect.Also the removal of Colloidal particles such as Colloidal Silica in the boiler feed water, The dairy industry uses UF technic for Whey Proteins separation.Molecular weight cut off is the criteria for the selection of type of membranes.Along with the hollow fine fiber type membranes , the Spiral wound ( similar to Reverse Osmosis) membranes are also actively used in the UF plants.The UF needs periodic (every 40-50 minutes depending on the feed water conditions ) Backwashing of 30-50 seconds. Which is of course done automatically. The in side to Out configuration mostly needs The periodic Chemical Enhanced Backwashing or CEB, with High pH  (10-11)  Sodium Hydroxide plus Hypo Chlorite, followed by Low pH of ( 3-4) with help  Citric acid or Dilute HCl. It is observed as per the design guidelines that The Out to In Configuration calls for Air Scouring and Hypo Backwashing instead of CEB. The CIP ( Cleaning in Place) is done generally for both, IN-OUT or OUT-IN configurations. Very similar to that of RO CIP cleaning procedure to Regain Flux.

    more..
  • Water Filtration Plant

    Water Filtration Plant

    455,000 Per

    • Automatic Grade: Automatic
    • Voltage: 440 V
    • Material: SS Etc.
    • Type Of Machines: Sand filter.carbon filter
    • Plant Application: Drinking
    • Frequency: 50 Hz
    more..
  • DM Plant

    Get Price Quote

    Belt Dryer, Sludge Dryers, environmental monitoring services

    more..
  • Ion Exchange Plants

    Get Price Quote

    Ion Exchange Plants, Pressure Sand Filter Plants, Solid Waste Treatment Plants

    more..
  • Filtration Plant

    Get Price Quote

    Filtration Plant, Solenoid Valves, RO Solenoid Valves

    more..
Filter by Locality