air conditioning lab equipments
Get Price Quote
Refrigeration and Air Conditioning Lab VRA-1 Air Conditioning Test Rig VRA-4 Water Cooling Tower VRA-2 Refrigeration Test Rig VRA-5 Computerized Refrigeration Test Rig VRA-3 Ice plant VRA-6 Computerized Air Conditioning Test
level control system
Get Price Quote
Level control system Maintaining the optimum level control system in the feed water tank is very important in order to ensure maximum temperature in feed water tank from condensate recovery & ensure the safety of the boiler. To achieve this without manual intervention, level control system is used. We offer a customized Level Control Systems for Boiler Feed water tank where hot condensate is preferred & utilized maximum, then hot water from any other sources & last preference to the cold make up water. This ensures that the energy of hot condensate & hot water from other sources is utilized
Best Deals from Electrical Equipments
Air Conditioning Laboratory Equipment
Get Price Quote
The range of air conditioning laboratory equipment is exclusively available with us who are up to the mark in terms of quality & its functions. Air conditioning lab equipment is designed with the special care & attention so that it can give its best performance under the opposite condition. The best part is that the air conditioning laboratory equipment offered by us is in accordance of the Indian & international quality standards. In addition, we are the leading air conditioning lab equipment manufacturer and exporters from India. RAC-04 Introduction âEEEâ Air conditioning Cycle Demonstration Unit i.e. âEEEâ Mini Air Conditioning Tutor is designed to carryout following experiments and study of air conditioning cycle in details for the students of Mechanical Engineering or Polytechnics. RANGE OF EXPERIMENTS 1. To demonstrate the basic Vapour Compression Cycle of Refrigeration. 2. To study theoretical cycles and plotting of T- and P.H. charts. 3. To study the properties of refrigerant at salient points of the cycle. 4. To find out refrigerating effect and work input, hence, actual and theoretical C.O.P. 5. To study functioning of vapour compression cycle at various evaporator temperatures. 6. To study compressor efficiency at varying functioning condition. This equipment is fully instrumented to demonstrate ' Refrigeration System ' with basic components and necessary controls. SPECIFICATIONS 1. Compressor - Hermetic Kirloskar make, Model AJ 11,Capacity 2355 Kcal/HR 2. Condenser - Air cooled suitable for above compressor with fan and motor 3. Evaporator - Suitable air cooled type fitted in the duct. 4. Expansion device - Thermostatic expansion valve Danfoss make orequivalent 5. Rotameter - for flow measurement of liquid refrigerant. Eureka make. 6. Refrigerant - R 22, charged with 1 ½ Kg, and extra : 2 kg 7. Energy meter - For power measurement of compressor , air heater and steamgenerator 8. Heater regulator - suitable capacity 9. Pressure gauge - Waree make, 2â dial, for HP and LP measurement. 10. Digital Temp. Indicator - For temp, measurement at various points.Range up to 300 C. 11. HPLP cutout - For safety of compressor, Ranco or equivalent make. 12. Orifice & manometer Inclined manometer and orifice plate for airflow measurement 13. Steam Generator - For steam injection. 14 Axial Fan - For forcing the air in the duct, 100 cfm 15. Air heater - 3 Nos, 0.5 KW capacity. 16. Dry - Wet bulb thermometer Zeal England mercury type for measurement of condition of air, 4 nos. 17. All equipment are suitably mounted on a painted sturdy angle frame and power coated panel. INSTRUCTION MANUAL An instruction manual is supplied with the apparatus which describes theory involved, range and procedure of experiments, along with necessary calculatons. SERVICES REQUIRED AC 220V 50 HZ supply. Space required : A bench area of approximately 5 m X 2 m. RAC-05 Introduction Heat pump is a machine which extracts heat from low grade heat sources and with addition of high grade energy in the form of electric motor or engine and delivers heat at a temperature. Suitable for either domestic, industrial or commercial purpose. EEE has designed Air and Water Heat Pump to demonstrate and analysis the cycle using refrigeration as a working fluid. The refrigeration cycle consists of Hermetically sealed compressor, water cooled condenser, filter/dryer, rotameter, thermostatic expansion valve, air evaporator and water evaporator with selector valves. Two additional rotameters are provided in water circuits of condenser and evaporator respectively to measure flow rates. Digital temperature indicator is provided to measure temperature at various position. THE LOW GRADE HEAT INPUT will be supplied by ambient air in the case of air evaporator or water in case of water evaporator, the HIGH GRADE ENERGY input will be supplied in the form of electrical energy to compressor. The amount of this input can be measured using energy meter. This tutor has been designed to achieve steady state within reasonable period so that students can complete their experiments within 2-3 hours. By varying operating conditions the performance of heat pump can be studied. SPECIFICATIONS 1) Compressor :- Hermetically sealed type Kirloskar make Ton capacity. 2) Condenser :- Water cooled type shell and coil condenser with refrigerant inside the tube. 3) Expansion valve :- Thermostatic Expansion valve. 4) Filter/ Dryer of suitable capacity. 5) Rotameter :- One for refrigerant circuit for R-12. One water Rotameter for condenser. One water rotameter for water evaporator. 6) Evaporator :- a) Water cooled type shell &coil evaporator with Refrigerant inside the tube. b) Air evaporator- finned tube type with fan and motor. 7) Multichannel Digital Temperature Indicator with Thermocouples to measure various temperatures. 8) H. P. L. P cutout. 9) Pressure gauge :- Two nos. For delivery and suction pressures. 10) Energy meter :- To measure power consumption of compressor motor. 11) Necessary valves, switches etc. 1/3 RANGE OF EXPERIMENTS 1) Determination of co-efficient of performance of unit when working as heat pump. 2) Energy balances for complete system over arrange of operating condition. 3) To determine overall heat transfer co-efficient for condenser and evaporator. 4) To observe effect of sub-cooling in the condenser on co-dfficient of performance of heat pump. INSTRUCTION MANUAL A technical Manual is supplied which gives details of the apparatus and procedure of experiments. SERVICES REQUIRED Single phase 230V. 15 Amp supply. Water supply continuous 20 lit/min. in two circuit for condenser and evaporator.
Electronic Equipments
Get Price Quote
Electronic Equipments, Electronic Dimmer, electronic lighting control circuit
Electrical Equipments
Get Price Quote
Electrical Equipments, circuit wires, Transformers
industrial electrical equipment
Get Price Quote
industrial electrical equipment, Agricultural Equipments, Automobile Parts
Electrical Equipment
Get Price Quote
Electrical Equipment, electric switchgear, Electric Transformers
Electrical Equipment
Get Price Quote
Electrical Equipment, Right Angle Adapters, screw accessories
Electrical Equipments
Get Price Quote
Electrical Equipments, injection syringes, Medical Equipments
Electrical Equipments
Get Price Quote
Electrical Equipments, Medical Equipments, consumer products
Electrical Equipment
Get Price Quote
Electrical Equipment, Electric Switches, Relay, Sensors, Proximity Switches
Electrical Equipment & Supplies
Get Price Quote
Electrical Equipment & Supplies, AC FHP Motor, Motor Gearboxes, Geared Motor