  • Ups for Xerox

    Ups for Xerox

    Request for Price

    off-line ups for xerox mc, deep freezer, air-conditioner & currency counting mc. : - rating : 3 kva-48 v dc 2 kva-24 v dc 1 kva-24 v dcoutput waveform on inverter mode - sinewaveoutput - 230 v ± 1% on inverter modetechnology - pwm high switching frequencydevice used - igbtmosfetcrest factor - 6:1ups cost with battery - competitivecan match with 2.5 hp genset pricecharger capacity : 10 to 15 ampcompact sizeeasy to installled's for indicationfast changeover time backup available : 1 hr 2 hrs 4 hrs ups for air conditioner of 1.0 ton, 1.5 ton, 2.0 ton : -rating : 5 kva-120 v dc168 v dc180 v dc off-line with without avr option available.technology : pwm high frequencydevice : igbt modulesolid statehigh crest factor : 6:1fast and smooth changeover timecold start feature availableoutput waveform on inverter mode : sinewavecost effective, ups price matches with equivalent rating of gensethigher inverter efficiency : >90%noiselessno maintenance; no pollutioninput voltage range : 180 - 260 v ac mains modeoutput voltage :180 - 260 vac - without avr on mains mode (option)200 - 240 vac - with avr on mains mode (option)230 v ± 1% - on inverter modeled indications : mains on, ups on, battery chargingcharger capacity : 10 to 15 ampsbackup available : 1 hr 2 hrs 4 hrs

    ...more
    Get Best Price
  • True Online Small UPS System

    True Online Small UPS System

    Request for Price

    We are offering true online small ups system. technology : intelligent ups, using igbt technology latest design : microcomputer-chip based switching frequency : high frequency, (greater than 17.5 khz.) to ensure low switching lossesspurity of sine-wave ultra-fast transient responsevery low noise wide input range : 350 v - 475 v ac (three phase) or 160 v - 270 v ac (single phase)45 - 60 hz accurate output : 415 v ac 1.0% (three phase) or230 v ac + 1.0 % (single phase) 50 hz + 0.1 % (crystal controlled) ratings : 1.0 - 60.0 kva output power factor : 0.8 lagging to unity transient response : for 100 % step load change output stays within + 5% and recovers within 12 cycle metering : on-board programmable lcd panel meter to display following parameters :output voltageinput voltagebattery voltagebattery currentoutput frequencyinput frequencyvarious conditionsparameter of ups powerordigital meter showing inputoutput volts through selection. wave form : pure sine wave distortion : total harmonic distortion less than 2% for linear load total harmonic distortion less than 5% for non-linear load overload rating : 100 % continuous 150% for 30 seconds operating temperature : 0 to 50o c, 95% r.h. (maximum)our ups has passess environmental - tests from defence laboratory of r&de (engineers), dighi, pune. inverter efficiency : better than 90% transfer time : zero genset compatibility :ups system is fully compatible to any type of genset protections :output over-voltageoutput overload. The same shall be effective only for the normal continuous operations.output short circuitbattery under-voltageforced air-cooling to protect electronic other components from overheating. indications :mainscharger oninverter onsystem over-loadbattery under-voltageoutput underover voltage alarms : mains fail (musical alarm)battery low warning (musical alarm) low noise : less than or equal to 45 db (a) (standard) at 1.0mtr. bypass arrangement :in-built solid-state static switch provided (for ups of 7.5 kva and above ratings)manual changeover switch provided (for 1.0 to 6.0 kva ups systems). battery charger :charger is designed on boosttrickle (cccv) principle to keep batteries in top condition.uses high frequency design to ensure long battery life. useful options : servo-voltage stabiliser for use in bypass modesynchronisedasynchronised inverter configurationcritical non-critical redundant upsdual-redundant (hot standbyload sharing) ups configurationscott - connected transformer for single phasing of input ac mains and steppingdown the mains voltage from 415 v to 270 v ac in bypass mode (recommended for 10.0 kva ups and above with 3- phase input)computer interface (rs-232) for automatic unattended shutdown of file- server & monitoring of battery status. Options available for novell- lannt-windowssco-unixlinux.remote control indications & alarms panel to control the ups functions from a distance.

    ...more
    Get Best Price
  • SMPS Battery Charger

    SMPS Battery Charger

    Request for Price

    The SMPS Battery Charger is serving the twin purpose of supplying the DC load and simultaneously charging 70 AH, 110 Volts SMF lead acid batteries. Input Rated operating Voltage : 3 Phase, 415 Volts 5%Limiting operating Voltage : 3 Phase, 415 Volts 15% Limiting operating current : 20 Amp Output Rated output Voltage : Function of (Battery voltage, battery current, temperature of the battery)< 135 V Battery charging current : 20 Amps Maximum Output Current : 50 Amps Maximum load current : 50 Amp minus battery charging current Maximum output power : 130 VX50 Amp = 6500 watts Ripple Current : V

    ...more
    Get Best Price
  • Shock Protector

    Shock Protector

    Request for Price

    Specifications for Shock Protector :- Green LED is for Unit ON. Red LED is for Earth fault. Input Voltage 230 ± 10%. Output Voltage230 ± 10%. Reset is not provided; to switch on the unit manually after earth leakage is cleared. Applications : Can be used with Geyser Boiler Iron Toaster Washing Machine

    ...more
    Get Best Price
  • power electronic component

    power electronic component

    Request for Price

    Get Best Price
  • Offline Ups

    Offline Ups

    Request for Price

    We are offering office uninterruptible power supply. rating : 500 va / 750 va / 1000 va input voltage range : 175 - 270 vac input frequency : 50 hz output voltage (mains) : 200-240 v output voltage (inverter) : 230 v ± 5% output frequency (inverter) : 50 hz ± 2% indications : mains oninverter on protection :system overload short circuit inverter over voltage in-built spike/surgesuppressor (mov) in-built emi/rfi filterinput high/low voltagelow battery trip batteries : sealed maintenance free batteries for 15-20 minutes battery backup. output socket : 5 amp. - 3 nos.

    ...more
    Get Best Price
  • lift ups

    lift ups

    Request for Price

    Technology : USING IGBT Technology Switching Frequency : High Frequency to ensure Low Switching Lossess, Purity of Sine-Wave, Very Low Noise Wide Input Range : 350 V - 475 V AC (Three phase) 45 - 60 Hz Accurate Output : 415 v AC 1.0% (Three Phase) 50 Hz + 0.1 % (Crystal Controlled) Ratings : 5.0 - 60.0 KVA O/P Power Factor : 0.8 lagging to unity Metering : LED Panel meter to display following Parameters (Optional):Output VoltageInput Voltage Battery VoltageInput Frequency Output FrequencyVarious conditions/Parameter of UPS Power etc. ORDigital Meter showing Input/Output Volts through selection. (STANDARD FEATURE) Overload Rating : 100 % Continuous 150% for 30 seconds Operating Temperature : 0 to 50o C, 95% R.H. (Maximum) Inverter Efficiency : Better than 90% Genset Compatibility : UPS System is fully Compatible to any type of Genset Protections : Output Over-VoltageOutput Overload. Output Short CircuitBattery Under-VoltageForced Air-cooling Indications :Mains/Charger ONInverter ONSystem Over-loadBattery Under-VoltageOutput Under/Over Voltage Alarms : Mains Fail & Battery Low Warning (Musical Alarm) Low Noise : Less than or Equal to 45 dB (A) (Standard) at 1.0mtr. Battery Charger : Charger is designed on Boost/Trickle (CCCV) principle to keep batteries in top condition.Uses High Frequency design to ensure long battery life. Mobile Connectivity : Provided (Optional)

    ...more
    Get Best Price
  • Green Power UPS

    Green Power UPS

    Request for Price

    Green Power UPS :- Rating : 1 KVA, 1.5 KVA, 3.0 KVA & 4.0 KVANominal Voltage : 36 V & 96 VIp : 230 ± 15%Op : 230 ± 1% Ip Power Factor : Greater than 0.98 to Unity. Overall efficiency : 85 % Inverter efficiency : 92 % Indication : Mimic Diagram, Mains INOFF, UPS ONOFF, Load Status, Battery %. Static switch provided. User friendly software (1)Shutdown provision(2)Electrical Parameters(3)Battery backup timeNo wiring No Site preparationApplications : Computer Training Institutes HospitalsChartered AccountantsTravel AgentsCollegesSchools

    ...more
    Get Best Price
  • Energy Saver

    Energy Saver

    Request for Price

    Energy-Saver - FridgeInput : 230 V +/- 10% Output : 230 V +/- 10%, 6 A Indication : Mains ON, Saver ON Delay : 3 minute for saver to start Dimension : 137 mm X 42 mm X 50 mm (for 6 A, Plastic body), 150 mm X 62 mm X 50 mm (for 16 A, Plastic body) No additional Isolation, Fuse, Protection provided Energy-Saver - A/C :Input : 230 V +/- 10% Output : 230 V +/- 10%, 20 A Protection : Under Voltage Saver bypass Indication : Mains ON, Saver ON Isolation : ON/OFF MCB,25 A Delay : 3 minutes for saver to start Dimensions : 200 mm X 180 mm X 65 mm - Metallic body No Fuse provided Metal clad socket provided Energy-Saver - Home :Input : 230 V +/- 10% Output : 230 V +/- 10%, 20 A Protection : Under voltage saver bypass Indications : Mains ON, Saver ON Isolation : Nil Delay : 1 minute for saver to start Termination : 32 A terminal strip is provided. Bypass : 15 A, 2 Pole, 2 way bypass switch No Fuse Dimensions : 200 mm X 200 mm X 52 mm Energy-Saver - Operational Principle & Advantages Background :No machine is perfect. Every machine has its own efficiency which is basically a ratio of output power to input power as a percentage. Machines mostly use popular induction motor (single Phase OR Three Phase); They rarely operate on full load and most of the time they operate on partial load or no load. Under such circumstances when the motor is on partial load or no load the power required by motor is less but actually excess power is fed to motor.Enertech's Energy Saver senses the exact power required by motor under different loading conditions and adjusts the power level to the motor's requirement. The excess power consumed in a motor (in the form of losses) is thus saved.There are no external capacitors required for Power Factor improvement. There is no starter required for this equipment. Existing starter will be continued in circuit.After saving the energy the motor speed remains same; motor KVA reduces, saving electricity.Principle of Operation :The energy saving is achieved through our proprietary firmware, which constantly monitors power factor of the load. Suitable program invokes correction of the Power Factor to ensure losses are reduced because of the inductive effect of the load.Working of Energy Saver :It can benefit all 1-phase & 3-phase induction motor users. It is generally observed that most AC Motors are under full load for only limited periods and at other times are operating on partial loading or no load conditions. Under those conditions energy is wasted as heat, vibration, magnetic losses. Unfortunately motors have no way of intelligently adjusting the amount of electricity they draw in relation to the work they do. If one can intelligently monitor and reduce the power drawn by a motor to match its actual need then there is a lot of scope to save energy. It uses a powerful Micro-Controller Electronics circuitry to supply proportional volts and allow required current to flow into the motor ensuring required torque potential is always available. The soft start facility reduces the maximum demand with smooth stepless acceleration minimizing strees on mechanical transmission system. Advantages of Energy Saver : Saves electrical energy and electricity bill depending on type of load and loading conditions upto 25% Reduces losses and increases efficiency (of motor, tube lights, fans) which reduces heating in motor winding, tube light chokes etc. Since, heating is reduced and energy saver has soft start (for motor) the average inrush current also reduces. Indirectly life of the motor increases. As electricity-billing rates are increasing these days, this equipment has a good pay back period. The statutory connected AC capacitors improve the Power Factor but make different in the RKVAR meter reading. However, this Energy Saver will make a difference in the ordinary meter readings also. Hence this Energy Saver will directly reduce your electricity bill.

    ...more
    Get Best Price
  • embedded software

    embedded software

    Request for Price

    We offer THREE different versions of UPS Software. The brief details are as under :Version 1 : Enermon - BasicEvent Monitoring Softwarea) Generates Auto Pop-up messages for different UPS events and warns the users. b) Automatic unattended/graceful shutdown of files / file-server.c) RS -232 Hardware interface is necessary for these operations.d) Recording Power events in the background without any user interaction. Supports viewing and printing of all UPS events with date and time stamp.e) Shows Power history log on file-server for events like Power failure, low battery, etc. f) Broadcasting of messages / faults of UPS, to all the connected Clients/Usersg) Provides Phone / Paging facility to transmit messages to Administrator or the Service provider.h) Each time the Server/Workstation is booted, the Software automatically begins monitoring the UPS status.i) Scheduling of UPS for Automatic Unattended Shutdown / Autostart.Version - 2 :Enermon - AdvancedPower Monitoring Software This version is more powerful and offers additional features as compared to the above basic version.a) Generates Auto Pop-up messages for different UPS events and warns the users. b) Each time the Server/Work Station is booted, the Software automatically begins monitoring the UPS Status. c) Gives reminders for maintenance of UPS, as Auto Pop up messages on the screen d) Automatic Unattended/Graceful Shutdown of files / file-server.e) Records information on the UPS Parameters in the background without any user interaction; supports viewing and printing of all parameters (like volts, current etc)f) Shows Power-History Log on Screen for events like Mains-failure, Low Battery, AC-over, etc. g) Notifies the users in LAN / WAN operation about events like Power-failure, Low- battery, etc. through broadcasting feature.h) Auto E-mail and Auto-Paging to predetermined E-mail ID / Pager No.. for service support. It uses intelligent micro-controller based hardware. Version - 3 :Enermon - RemoteInternet-Based Power Management SoftwareSimple Network Management Protocol (SNMP) monitors devices like UPS, connected across its network. Use of Enermon-Remote permits the Remote -Management of UPS through use of Internet.Besides above features this offers following :a) All the electrical parameters of UPS at Remote point such as Input / Output Voltage, Input / Output Current, Power-factor, KVA, KW, KVAR, etc. can be monitored. b) It requires installation of Hardware & Software in the computer near UPS & software at remote location.c) UPS fault conditions such as DC-under volt, AC-under volt, AC-over voltage, etc. can also be monitored remotely.d) You can set parameters like UPS schedule (Night Shutdown / Morning Wake Up time), Operating system shutdown etc.e) Broadcasting of messages / faults in UPS, Auto Email & Auto Paging to predefined E-mail ID/Pager Number facility available.f) Through SNMP you can configure your UPS to offload its information(Data, events, and health) to your registered file- server. Thereafter, all the authorised users can see the status of the remotely located UPS systems.g) Battery-related parameters like battery-capacity, battery-health, battery-voltage, and charge/discharge current can also be monitored.We offer the above solutions for Windows 95/98, NT-Windows, Novell LAN and Linux Operating Systems.

    ...more
    Get Best Price
  • drink vending machine

    drink vending machine

    Request for Price

    User Friendly Operations : - Press READY switch for operation. Press switches (Flavour 1 or 2 or 3 ), according to your choices of flavour. The drink is dispensed in the glass. Flush switch is for internal use i.e. cleaning of dispensing tank or to get cold water. Locking facility is available by pressing password key to avoid misuse and stop usage of the machine through keypad Counter gives information on glasses dispensed and balance available after pressing count switch. User Programming Keypad : This is available to modify quantity of powder, water to be dispensed in the glass to satisfy users taste. Choice of Fruit Powder or Squash like Kokam, Pineapple, Mango etc. can be filled and entered. This will give the name of Powder or Squash on the screen when it is dispensed. Technical Specifications of Cold Drink Vending Machine :Electrical : Operates on 230 V AC ± 10%.Power Consumption : Maximum current, 1 AmpsInput Cable : 5 A, 3 Pin top moldedMotor : 0.25 HPDimensions (in mm) : 230 (H), 550 (D), 500 (W)Enclosure : Stainless SteelWeight of unit including compressor : 25 Kgs. Approx.Switches for Front Operation : Membrane KeyboardReady, Flush, Flavour 1 / Flavour 2/ Flavour 3 / Cold Water / CountEnclosure : Stainless SteelLCD Display :Ready FlushFlavour 1Flavour 2Flavour 3Cold WaterPlease Wait Count - No. of glasses consumed, No. of glasses balance (Optional)Special Features :You can place a large inverted water tank of 20 ltr. capacity on the machine. This will adding water to the 10 ltr. tank inside the machine. For 24 hrs. online operation of water, please connect to waterline. Necessary provisions has been made.Optional available : Squash or Powder.Safety Features Provided :Fully Shock-proofEasy to OperateEasy to CleanEasy to InstallVermin ProofRust ProofFruitpunch : The Energy Drink Vending machine that serves Non-Aerated chilled fruit drinks to your customers and employees at your premises using plain / bottled water. Serve chilled fruit drink of 250 ml. glass in 15 seconds, with choice of 3 flavours.The FRUITPUNCH has highly advanced fully automated cleaning system in its operation ensuring that the user enjoys a very hygenic and chilled fruit drink at 40 CServing per hour : 200 glasses of 250ml.Number of servings with full load (i.e. 1 kg) of Powder : 40 glasses of 250 ml.

    ...more
    Get Best Price
  • AC / DC Inverter

    AC / DC Inverter

    Request for Price

    Specification for 2.5 KVA, 110 VDC230 AC InverterTechnical Requirements :Input Voltage (MinNomMax.) : 90 V110V140V with 15% ripple Output Voltage : 230 V AC +-5%, 50 Hz for input voltage range of 90 to 140 V DC from no load to full load. Rated capacity : 2.5 KVA at 90 V DC Continuous KVA Rating : 2.5 KVA Wave form : SinusoidalPWM, THD not exceeding 3%. Cooling : Natural air cooled Efficiency : Shall not be less than 85% at full load Protection : Input MCBs and fusesPolarity reversal at input side.Frequency beyond 50 +- 3%Voltage surge supressor at inputOver voltage at the input and outputOver current protectionShort circuit at outputEarth protectionConstructional Requirements : The enclosure shall be such as to prevent ingress of brake block shoe dust liable to get attracted by the magnetic effect of the equipment. The enclosure shall meet the requirements of IP-65 protection level of IS:2147 (Latest edition). All the metal parts shall be protected from rust and corrosion. Sheet thickness will not be less than 1.6 mm. Overall Dimension : W = 500 mm, L = 450, H = 375 mm as per drg. No. SKED 055 alt. 'a'.

    ...more
    Get Best Price
  • Online UPS Systems

    Online UPS Systems

    Request for Price

    Get Best Price
  • energy saving systems

    energy saving systems

    Request for Price

    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

Contact Information

Enertech Ups Pvt. Limited

  • V. K. Deshpande
  • 399/1-2,Bhare, P. O. Ghotawade (near Piraqngut) Tal. Mulshi., Pune, Maharashtra
top