Gas Flow Meter
Get Price Quote
Gas Flow Meter
Get Price Quote
These meters are based on the principal of differential pressure generated by Orifice element. Designed as per ISO5167BS1042. On line density compensation delivers very accurate results. Various Types of IBRNon IBR valves for isolation and drain. Various Sizes of Orifice Assemblies with or without IBR Certificate. Complete System is Engineered to suite your requirements. Highly Reliable and Repeatable System; No Moving Parts. Easy for Calibration.
Best Deals from Gas Measurement Instruments
Gas Flow Meters
Get Price Quote
Gas Flow Meter
Get Price Quote
Gas Flow Meter
Get Price Quote
These meters are based on the principal of differential pressure generated by Orifice element. Designed as per ISO5167/BS1042. On line density compensation delivers very accurate results. Various Types of IBR/Non IBR valves for isolation and drain. Various Sizes of Orifice Assemblies with or without IBR Certificate. Complete System is Engineered to suite your requirements. Highly Reliable and Repeatable System; No Moving Parts. Easy for Calibration.
lpg flow meters
15,000 - 60,000 Per Piece
2 Piece(s) (MOQ)
We have come up with reliable LPG Flow Meters. The LPG Flow Meters that we offer are manufactured with the use of best quality components that impart strength and endurance. Our LPG Flow Meters provide accurate readings of the flow with an absolute ease. Our LPG Flow Meters are sophisticated and work with utmost precision. Principle of Operation LPG Flow Meters The operation of the International Gas Turbine Meter is based on the measurement of the velocity of gas.The flowing gas is accelerated and conditioned by the meter´s straightening section. The straightening vanes prepare the gas flow profile by removing undesired swirl, turbulence and asymmetry before the gas flows to the turbine wheel.The Dynamic Forces of the Flowing Fluid/Gas cause the rotor to rotate. The turbine wheel is mounted on the main shaft, with special high precision, low friction ball bearings.The turbine wheel has helical blades that have a known angle relative to the gas flow. The conditioned and accelerated gas drives the turbine wheel with an angular velocity that is proportional with the gas velocity.The rotating turbine wheel drives the index head with the eight digit mechanical counter via shafts and gears.The volume and flow rate can also be indicated electronically. A proximity probe generates a signal at each passing blade of the turbine wheel. With the device-specific K-factor and the number of pulses, the passed volume can be calculated. With the measured frequency the flow rate can be determined.The rotating turbine wheel can also generate pulses directly by proximity sensors that create a pulse for each passing turbine blade. By accumulating the pulses the total passed volume and gas flow rate can be calculated. General This is a highly accurate flow meter, approved for custody transfer measurement, equipped with electronic pulse outputs and a mechanical counter. This document explains the dimensions, ranges, performance, calibration and outputs of the instrument. It details the installation, safety requirements and material specifications. The Gas Turbine Flow Meter measures gas volume flowing through an annular passage in the meter. The flowing gas volume is totalized on a local mechanical counter. In addition, low or high frequency pulse signals are generated to infer the gas flow and volume. The indicated gas volume is the actual volume flowing through the meter at the actual temperature and pressure. The Gas Turbine Flow Meter is available in two models.The Gas Turbine Flow Meter is used for high accuracy and custody transfer applications. The Gas Turbine Flow Meter is an economically priced meter with a good accuracy.Gas TypesThe Gas Turbine Flow Meter in its standard design can be used for all non-aggressive gases, such as natural gas, methane, propane, butane, city gas and fabricated gas, air, nitrogen, etc. For aggressive gases, like sour gas, biogas and oxygen, special designs are available with Teflon coating, special lubrication or special purging. See table 1, for detailed requirements or different type of gases. Temperature Ranges As standard The Gas Turbine Flow Meter is designed to operate at temperatures between -10oC to 60oC. Special low and high temperature designs are available on request. Standard accuracy limits for Custody Transfer models are in accordance with the EC directives and many foreign regulations : ± 0.5% for 0.2 Qmax to Qmax± 0.5% for Qmin to 0.2 Qmax As an option for the Custody Transfer model the accuracy limits can be improved to : ± 0.2% for 0.2 Qmax to Qmax± 0.3% for Qmin to 0.2 Qmax These limits are valid for the meter performance in ambient air. Usually, the performance is better at high-pressure applications. On request we can offer meters according to your accuracy specification. The repeatability of the LPG Flow Meters is better than 0.1%Material of Construction: Material of Construction Gas Turbine Flow Meter Regularly Stainless Steel 316 L. Principle of Operation: As Above. Nameplate Detail: Measurement systems group.Index head and pulse transmitters: stainless steel measurement systems group make. Fully intrinsic free hazardous free, potential freeMaximum operating pressure: manufactured as per requirementRequired upstream and downstream length: as required.Lubrication system: without bearings.Lubrication before start-up: without bearings.Regular lubrication: without bearings.Volume conversion: mass flow meter direct calibration on appl.gas.Flow direction and orientation: as indicated on flow meter.Connection pressure transmitter: NA for volumetric/mass flow meter ss316 l pressure transmitter. Pressure compensated.Temperature Measurement: Temperature compensated. Warranty : One Year Warranty. 7-digit total flow displayFlow Rate 3 %1/2 digits displayProgrammableExternal battery backupProgramming lock4-20 ma OutputRS-485 Port for interfacing with computerFlow Rate, total flow one touch switching modeDigital switching outputs have LED status indicatorsFront panel environmental protection to IP65 (IP40 for rear of unit)Compact DesignSpecialized for measurement systems sensors Specifications Supply voltage : 230V ACSupply current : NAMax output load current : NAMax output load voltage : NAInternal voltage drop : NADisplay units - rate : l/min, US gal/minDisplay units – volume : liters, US gallonsRepeatability : ±0.5% FS or lessLinearity : ±1.0% FS or lessResponse time : 1 second maxTemperature range : 0 to 80oCIP rating - front panel : IP65IP rating - enclosure : IP40Weight : 245 g Flow Rates Flow Rate measurement range : NAK Factor : NA The Systems RS-485 to USB is a USB to RS485 converter. It allows easy serial port expansion without requiring IRQ, DMA, or I/O port resources. The converter allows the user to easily and economically connect RS485 devices to a host using USB. The RS485 communications standard is used by Measurement Systems Pickoff Sensor based data acquisition modules and many industrial control devices. The converter is based on a single chip USB UART for transferring serial data over the Universal Serial Bus without the need for card-slots. The converter has an internal 128 byte transmit buffer and a 384 byte receive buffer. It supports baud rates of up to 230K. External power is not required since takes its power from the bus. Connection to USB is via a 3-foot detachable cable. Connection to RS485 is thru the converters DB-9 male connector. The converter is housed in a plastic enclosure designed for rugged applications. The converter can interface RS485 modules to a host using a USB connection, when using the Measurement Systems RS-485 to USB with a module or any RS485 device that requires wiring, recommends its’ CA-3 cable. The CA-3 is a 3-foot serial cable with a female DB-9 connector and tinned wires ready for connection to RS485. We Have Recently Developed a Portable Flow meter. The Portable Flow meter Works on the Inbuilt Battery of the Totalizer.
Gas Flow Meter
19,000 - 54,960 Per piece
1 Piece (MOQ)
CORI MASS INDIA Make special Mass flow meters for BIOGAS flow Measurement give accuracy of 1 % FS and are truly Mass Flow meters calibrated in Kg. The unloading of the Liquid BIOGAS in tanks and then measuring the consumption can be measured/matched / verified / logged using the accurate mass flow meters.
Gas Turbine Flow Meter
Get Price Quote
1 Piece(s) Piece (MOQ)
The Gas Turbine Flow Meter, which we offer, measures gas volume flowing through an annular passage in the meter. The flowing gas volume is totalized on a local mechanical counter. In addition, low or high frequency pulse signals are generated to infer the gas flow and volume. The indicated gas volume is the actual volume flowing through the meter at the actual temperature and pressure.The Gas Turbine Flow Meter is available in two models The Gas Turbine Flow Meter is used for high accuracy and custody transfer applications. The Gas Turbine Flow Meter is an economically priced meter with a good accuracy. Gas Types: The Gas Turbine Flow Meter in its standard design can be used for all non-aggressive gases, such as natural gas, methane, propane, butane, city gas and fabricated gas, air, nitrogen, etc. For aggressive gases, like sour gas, biogas and oxygen, special designs are available with Teflon coating, special lubrication or special purging. See table 1, for detailed requirements or different type of gases. Measurement Systems Gas Turbine Flow Meter are designed for precise metering of all non-aggressive gases and fuel gases such as natural gas, propane, butane, ethane, coke oven gas, town gas, acetylene, nitrogen, carbon- dioxide, air and all inert gases. These are available for flows up to 50000 actual M3/Hr. These Gas Turbine Flow Meters are approved by Legal Methodology for Custody Transfer Application. Gas Turbine Flow Meter has a wide range of 20:1.The meter incorporates Direct Reading Local Electronics Totalizer. Option of Pulse Transmission for remote indication is available. Flow Computers and Volume Correctors are available as optional.Temperature Ranges : As standard The Gas Turbine Flow Meter is designed to operate at temperatures between -10oC to 60oC. Special low and high temperature designs are available on request.Standard Accuracy Limits For Custody Transfer Models Are In Accordance With The Ec Directives And Many Foreign Regulations ± 0.5% for 0.2 Qmax to Qmax ± 0.5% for Qmin to 0.2 Qmax As An Option For The Custody Transfer Model The Accuracy Limits Can Be Improved To ± 0.2% for 0.2 Qmax to Qmax ± 0.3% for Qmin to 0.2 Qmax Material of Construction : Material of Construction Gas Turbine Flow Meter Regularly Stainless Steel 316 L. Details - Flow Meters With Remote Display Extrinsic Proof Certified, High Accuracy Calibration Certificate Warranty - 1 Year Turbine Type and Differential Pressure- Venturi Type Flow MetersMaterial Used - Steel Sizes Available 0mm 10mm 15mm 20mm 32mm 40mm 50mm 65mm 80mm 100mm 125mm 150mm 200mm 250mm 300mm 400mm 500mm 600mm 800mm 100mm
Gas Meter
25,000 Per Piece
Gas flowmeter for measurement of gas flow in industrial applications.high pressure or low pressure,high flow or low flow,high and low temperature all line size.
Gas Flow Meters
Get Price Quote
1 Piece(s) (MOQ)
We have Gas Flow Meters within the working range of the meter the rotor spins proportional to the actual velocity of gaseous material flowing. A pick-up coil produces an electrical signal as each blade crosses through its low magnetic or rf field. This signal is amplified and conditioned by a transmitter or fed directly into a rate/totalizer, and represents the actual cubic feet per minute (acfm) flowing through the meter. The k-factor is stenciled on the meter body in pulses per actual cubic feet (p/acf). Because gases are compressible, most people desire to measure the equivalent amount of gas corrected for the line pressure and temperature to standard cubic feet per minute (scfm at 60â°f, 14.69 psia). If the flow temperature and pressure are relatively constant, then a simple correction can be calculated to shift the k-factor from p/acf to p/scf and a simple totalizer (measurement systems india make ) may be used. When flow temperature and pressure are not constant, a flow computer. specifications linearity 1 â±1.0%/0.5% repeatability 1 â±0.25% maximum over-range 125% of flow rate for intermittent periods frequency output 0 to 1,100 hz voltage output approximately 100 mv@ 100 hz to 1.5 v (rms)@ 1,000 hz. Pressure drop 0.5 psi at 100% of flow range pressure rating we manufacture flowmeters for most pressures. installation vertical or horizontal (any direction). Materials of construction body: 316 l stainless steel. Flanges: 316 stainless steel rotor: 431 stainless steel. Rotor shaft/bearings: standard: tungsten carbide v-cup cartridge frame retainer: 302 stainless steel cartridge frame: 316 l stainless steel. Temperature range:meter with bearing structure of: standard: tungsten carbide: -40â°f to 300â°f (-40â°c to 149â°c). For other temperatures consult factory.
Industrial Oxygen Flow Meter
Get Price Quote
Industrial Oxygen Flow Meter, Air / Gas Flow Meter, Digital Flow Meter
Gas Meter
Get Price Quote
Gas Meter, air flow sensor
Gas Flow Meter
Get Price Quote
Gas Flow Meter
residential diaphragm gas meter
Get Price Quote
residential diaphragm gas meter
Oxygen Flow Meter
Get Price Quote
Oxygen Flow Meter