Lpg Flow Meter
Get Price Quote
We have come up with reliable LPG Flow Meters. The LPG Flow Meters that we offer are manufactured with the use of best quality components that impart strength and endurance. Our LPG Flow Meters provide accurate readings of the flow with an absolute ease. Our LPG Flow Meters are sophisticated and work with utmost precision. The LPG Flow Meter Systems RS-485 to USB is a USB to RS485 converter. It allows easy serial port expansion without requiring IRQ, DMA, or I/O port resources. The converter allows the user to easily and economically connect RS485 devices to a host using USB. The RS485 communications standard is used by Measurement Systems Pickoff Sensor based data acquisition modules and many industrial control devices.The LPG Flow Meter is based on a single chip USB UART for transferring serial data over the Universal Serial Bus without the need for card-slots. The converter has an internal 128 byte transmit buffer and a 384 byte receive buffer. It supports baud rates of up to 230K. External power is not required since takes its power from the bus. Connection to USB is via a 3-foot detachable cable. Connection to RS485 is thru the converters DB-9 male connector. The converter is housed in a plastic enclosure designed for rugged applications.The converter can interface RS485 modules to a host using a USB connection, when using the Measurement Systems RS-485 to USB with a module or any RS485 device that requires wiring, recommends its’ CA-3 cable. The CA-3 is a 3-foot serial cable with a female DB-9 connector and tinned wires ready for connection to RS485. We Have Recently Developed a Portable Flow meter. The Portable Flow meter Works on the Inbuilt Battery of the Totalizer. Principle of Operation LPG Flow Meters - The operation of the International Gas Turbine Meter is based on the measurement of the velocity of gas. The flowing gas is accelerated and conditioned by the meter´s straightening section. The straightening vanes prepare the gas flow profile by removing undesired swirl, turbulence and asymmetry before the gas flows to the turbine wheel. The Dynamic Forces of the Flowing Fluid/Gas cause the rotor to rotate. The turbine wheel is mounted on the main shaft, with special high precision, low friction ball bearings. The turbine wheel has helical blades that have a known angle relative to the gas flow. The conditioned and accelerated gas drives the turbine wheel with an angular velocity that is proportional with the gas velocity. The rotating turbine wheel drives the index head with the eight digit mechanical counter via shafts and gears. The volume and flow rate can also be indicated electronically. A proximity probe generates a signal at each passing blade of the turbine wheel. With the device-specific K-factor and the number of pulses, the passed volume can be calculated. With the measured frequency the flow rate can be determined. The rotating turbine wheel can also generate pulses directly by proximity sensors that create a pulse for each passing turbine blade. By accumulating the pulses the total passed volume and gas flow rate can be calculated. General - This is a highly accurate flow meter, approved for custody transfer measurement, equipped with electronic pulse outputs and a mechanical counter. This document explains the dimensions, ranges, performance, calibration and outputs of the instrument. It details the installation, safety requirements and material specifications. These limits are valid for the meter performance in ambient air. Usually, the performance is better at high-pressure applications. On request we can offer meters according to your accuracy specification. The repeatability of the LPG Flow Meters is better than 0.1% Principle of Operation - As Above. Nameplate Detail - Measurement systems group. Index head and pulse transmitters - stainless steel measurement systems group make. Fully intrinsic free hazardous free, potential free Maximum operating pressure - manufactured as per requirement Required upstream and downstream length - as required. Lubrication system - Without bearings. Lubrication before start-up - Without bearings. Regular lubrication - Without bearings. Volume conversion - Mass flow meter direct calibration on appl.gas. Flow direction and orientation - as indicated on flow meter. Connection pressure transmitter - NA for volumetric/mass flow meter ss316 l pressure transmitter. Pressure compensated. Temperature Measurement - Temperature compensated.
Lpg Gas Meter
Get Price Quote
1 Piece(s) (MOQ)
within the working range of the meter the rotor spins proportional to the actual velocity of gaseous material flowing. a pick-up sensor produces an electrical signal as each blade crosses through its low magnetic or rf field. this signal is amplified and conditioned by a transmitter or fed directly into a rate/totalizer, and represents the actual cubic feet per minute (acfm) flowing through the meter. the k-factor is stenciled on the meter body in pulses per actual cubic feet (p/acf). because gases are compressible, most people desire to measure the equivalent amount of gas corrected for the line pressure and temperature to standard cubic feet per minute (scfm at 60â°f, 14.69 psia). if the flow temperature and pressure are relatively constant, then a simple correction can be calculated to shift the k-factor from p/acf to p/scf and a simple totalizer (measurement systems india make ) may be used. when flow temperature and pressure are not constant, a flow computer. specifications linearity 1 â±1.0%/0.5% repeatability 1 â±0.25% maximum over-range 125% of flow rate for intermittent periods frequency output 0 to 1,100 hz voltage output approximately 100 mv@ 100 hz to 1.5 v (rms)@ 1,000 hz. pressure drop 0.5 psi at 100% of flow range pressure rating we manufacture flowmeters for most pressures. installation vertical or horizontal (any direction). materials of construction body: 316 l stainless steel. flanges: 316 stainless steel rotor: 431 stainless steel. rotor shaft/bearings: standard: tungsten carbide v-cup cartridge frame retainer: 302 stainless steel cartridge frame: 316 l stainless steel. temperature range:meter with bearing structure of: standard: tungsten carbide: -40â°f to 300â°f (-40â°c to 149â°c). for other temperatures consult factory.
Best Deals from LPG Meter
LPG Flow Meter 02
Get Price Quote
2 Piece(s) (MOQ)
Clients can avail from us, precision engineered LPG Flow Meter. This LPG Flow Meter is manufactured with the use of latest technology ensuring accurate readings. This LPG Flow Meter is provided at economic prices.