venturi principle flow meters
2 Piece(s) (MOQ)
We keep in consideration that the inputs (raw material) used are of incredible quality and meet the set industrial norms. Thus, the final products are as per the globally accepted quality standards. Stay rest assured for the products that we offer as they will remain damage free. For this, we make use of only premium packaging material for the packing of the products.
...moreThermal Mass Flow Meter
25,000 - 60,000 Per Piece
2 Piece(s) (MOQ)
We are listed amongst prime Industrial Thermal Mass Flow Meter Manufacturers in India. Our Thermal Mass Flow Meters are designed to measure mass flow rate and solve the problems that create confusion in the measurement of gas flow (low velocity, large diameter, flow changes in a wider area, and the temperature and pressure changes, etc. Moreover, the customers are eased with the availability of the Thermal Mass Flow Meters with all the advanced configurations. Features Outstanding Range AbilityNegligible Pressure DropNo Moving PartsCost-EffectiveEasy InstallationDirect Mass Flow MonitoringNonlinear Amendment Applications Petro-chemistryMetallurgyElectricityMunicipalPaperPharmaceuticalWater Treatment Principle Thermal sensor consists of two sensing elements-a velocity sensor and a temperature sensor that automatically corrects for velocity sensor to a constant temperature differential above the gas temperature and measures the cooling effect of the gas flow. The electrical power required to maintain a constant temperature differential is directly proportional to the gas mass flow rate.
...moresanitary flow meters
25,000 - 90,000 Per Piece
2 Piece(s) (MOQ)
We present highly advanced Sanitary Flow Meters. The Precision turbines of the meter are manufactured with the use of bets quality components and raw materials to ensure efficiency. Our Sanitary Flow Meters bring a new level of reliability and performance to beverage, food and pharmaceutical. Sanitary Flow Meters is ideal for sampling and small batch applications. The Sanitary Series Precision Flow Meters are and electro-polished to eliminate cracks or crevices that can cause failure and unacceptable downtime. They are available in sizes from extremely versatile; our precision Turbine Flow Meters can be installed horizontally or vertically. These Sanitary Flow Meters deliver linerity and +/-0.1% repeatibility and handle ranges from_ 100oF to + 450oF and be cleaned with low-pressure steam while in – line. Sanitary Flow Meters Specifications Standard precision sanitary flow meters are (other materials are available to meet most) Minimum of 30 mV pp at the bottom of the 4 psi at maximum nominal rated flow range. Calibration (special calibrations available) Features Special food-grade PTFE or Carbine sleeve In-Line cleanup with low pressure steam 3A certified instrument specifically designed for sanitary, food-grade applications. It is compatible with nominal diameters form one inch and with flow rates from 8 to 1,200 Liner : PTFE +/-0.2% accuracy over 10:1 range w/ Dimension : Precision Turbine Flow Meters Typical Applications Food Dairy (Milk) Broths Lotions Food Dairy Beverage Pharmaceutical Biotech About Pickup Coil Operable with temperatures from_100oF to + 450oF (_37.3oC to + 232oC) _ High Temperature Pickup coil Operable from _ 100oF to + 750oF (_37.3oC to + 398.9oC)
...moreoil meters
2 Piece(s) (MOQ)
We are flexible enough to offer the finest and best in class oil meters; we are a leading Supplier in this domain. With the best in class raw material comes a remarkable finished product, thus we keep a stern check on the material used. Our quality auditors ensure that the products are up to the mark.
...moreOil Flow Meters
15,000 - 35,000 Per Piece
2 Piece(s) (MOQ)
We are the major Oil Flow Meters Manufacturer, Exporter and Supplier in Pune, Maharashtra. Our Oil Flow Meters are highly efficient as we manufacture them using high quality components and other raw materials. Our Oil Flow Meters have specialty in measuring low flows. Our Oil Flow Meters can work on any temperature, pressure or flow and provide correct readings. Specifications Manufactured for all lines sizes Suitable for any pressure, temperature and flow rate Resettable/ program display Rs 485 data interface Full SS-316 Body SS-316L Turbine
Application : Industrial, Residential
Operating Temperature : 10-50D/C, 50-100D/C
Driven Type : Electric
Warrenty : 1 Year
...moremass flow controllers
35,000 Per Piece
1 Pair (MOQ)
Mass Flow Controller Performance Thori Mass Flow Controller Accuracy at calibration conditions after tare ±(2% F.S) Zero Shift and Span Shift ± 0.2% FS / °C Repeatability ± 0.5% Reading Long term drift 0.05% Full Scale / Year Operating Range / Turndown Ratio 0 : 25 Maximum Controllable Flow Rate 102% Full Scale Typical Response Time 100 ms Warm-up Time 70 ms to full scale accuracy Valve Leak Specifications Internal (leak through) 10-5 atm – cc/sec He External (leak out) 10-9 atm – cc/sec He Operating Conditions Thori Mass Flow Controller Calibration Conditions 25°C, 14.696 psia Operating Temperature 0 to +50 ºCelsius Humidity Range (Non–Condensing) <90% Maximum Internal Pressure (Static) 100 PSIG 100 PSIG Proof Pressure 100 psig Vibration Nil. Mounting Attitude Sensitivity Yes. Valve Type Normally Closed Ingress Protection IP40 Wetted Materials Aluminium & Brass. Communications / Power Thori Mass Flow Controller Digital Input / Output Signal Via 4-20 mA Analog Input / Output Signal 0-5 Vdc Optional. Electrical Connection Options 9-pin male D-sub (DB9) Supply Voltage 10 to 30 Vdc or Works On Loop Power. Supply Current 200 mA Features Thori Mass Flow Controller Notes. Units calibrated with Air have built-in correction equations that allow you to use the gas select command to switch to Argon, Carbon Dioxide, Nitrogen, Oxygen, or Nitrous Oxide. Note: PFC-CC-1000 units that are set to Carbon Dioxide or Nitrous Oxide are limited to a maximum flow rate of 750 sccm instead of 1000 sccm due to the correction factor equations used for these gases. Note: PFCL020 units that are set to Carbon Dioxide or Nitrous Oxide are limited to a maximum flow rate of 15 slpm instead of 20 slpm due to the correction factor equations used for these gases. Note: Units calibrated with Hydrogen or Helium can function only with that gas. Model No Flow Range Min Flow Max Flow Accuracy PFC-CC-002 0 to 2 SCCM 0.1 SCCM 0 to 2 SCCM +/- 2 % PFC-CC-005 0 to 5 SCCM 0.1 SCCM 0 to 5 SCCM +/- 2 % PFC-CC-010 0 to 10 SCCM 0.1 SCCM 0 to 10 SCCM +/- 2 % PFC-CC-020 0 to 20 SCCM 0.1 SCCM 0 to 20 SCCM +/- 2 % PFC-CC-050 0 to 50 SCCM 0.1 SCCM 0 to 50 SCCM +/- 2 % PFC-CC-0100 0 to 100 SCCM 0.1 SCCM 0 to 100 SCCM +/- 2 % PFC-CC-0200 0 to 200 SCCM 0.1 SCCM 0 to 200 SCCM +/- 2 % PFC-CC-0250 0 to 250 SCCM 0.1 SCCM 0 to 250 SCCM +/- 2 % PFC-CC-0500 0 to 500 SCCM 0.1 SCCM 0 to 500 SCCM +/- 2 % PFC-CC-0750 0 to 750 SCCM 0.1 SCCM 0 to 750 SCCM +/- 2 % PFC-CC-1000 0 to 1000 SCCM 0.1 SCCM 0 to 1000 SCCM +/- 2 % PFC-L-002 0 to 2 LPM 0.1 LPM 0 to 2 LPM +/- 2 % PFC-L-005 0 to 5 LPM 0.1 LPM 0 to 5 LPM +/- 2 % PFC-L-010 0 to 10 LPM 0.1 LPM 0 to 10 LPM +/- 2 % PFC-L-020 0 to 20 LPM 0.1 LPM 0 to 20 LPM +/- 2 % PFC-L-050 0 to 50 LPM 0.1 LPM 0 to 50 LPM +/- 2 % PFC-L-0100 0 to 100LPM 0.1 LPM 0 to 100 LPM +/- 2 % PFC-L-0200 0 to 200LPM 0.1 LPM 0 to 200 LPM +/- 2 % PFC-L-0250 0 to 250LPM 0.1 LPM 0 to 250 LPM +/- 2 % PFC-L-0500 0 to 500LPM 0.1 LPM 0 to 500 LPM +/- 2 % PFC-L-0750 0 to 750LPM 0.1 LPM 0 to 750 LPM +/- 2 % PFC-L-1000 0 to 1000LPM 0.1 LPM 0 to 1000LPM +/- 2 %
Type : Mass Flow Controllers
Condition : New
Power : 1-3kw
Driven Type : Electric
Warranty : 1year
Automation Grade : Automatic
Brand Name : Precision Flow Control Instruments
Application : Laboratory and Scientific Automation
Theory : Mass Control
Medium : Pneumatic and Liquids/ Mixtures/ Solutions.
Accuracy : 1.00% F>S
Connection : 1/4 Inch or 1/2 Inch Threaded
Output : 4-20 mA or 0 to 10 V DC
Temperature : 0 to 100 Degree Cel.
Repeatability : 1.00% F>S
Application : For Control Of Flow Rates
Accuracy : 1.00% F.S
Accuracy : 1.00%
...moremass flow controller
35,000 - 600,000 Per Piece
2 Piece(s) (MOQ)
We are an eminent Manufacturer, Supplier and Exporter of Mass Flow Controllers from Maharashtra. The Mass Flow Controllers we make available eliminate gross errors of volumetric low measurement. We maintain a large stock of the Mass Flow Controllers in our spacious warehouse, to cater the bulk and urgent requirements of the buyers. The entire range of the Mass Flow Controllers is reasonably priced by us. Details The MFM has been developed using the 4 year�s mass flow measurement & control experience within MFML to produce a practical, low cost, rugged flowmeter suitable for demanding industrial applications. There are no moving or delicate parts within the flow passage so the MFM is therefore very rugged indeed. As a Rotameter replacement, they provide 5 times better performance with an electrical output linear with flow, which may be used for logging and control purposes. The unobstructed internal flow passages are easily cleaned with suitable solvents should the flowmeter become contaminated in use. With a temperature range from 15 to 50°C, the MFM performs well in elevated gas temperatures and ambient environments.
Weight : 100-1000kg, 4000-6000kg
Voltage : 110V, 440V
Condition : New
Driven Type : Electric
Warranty : 2years
Automation Grade : Automatic
...moreLpg Gas Meter
1 Piece(s) (MOQ)
within the working range of the meter the rotor spins proportional the actual velocity of gaseous material flowing. a pick-up sensor produces an electrical signal as each blade crosses through its low magnetic or rf field. this signal is amplified and conditioned by a transmitter or fed directly into a ratetotalizer, and represents the actual cubic feet per minute (acfm) flowing through the meter. the k-factor is stenciled on the meter body in pulses per actual cubic feet (pacf). because gases are compressible, most people desire to measure the equivalent amount of gas corrected for the line pressure and temperature to standard cubic feet per minute (scfm at 60ã�â°f, 14.69 psia). if the flow temperature and pressure are relatively constant, then a simple correction can be calculated to shift the k-factor from pacf to pscf and a simple totalizer (measurement systems india make ) may be used. when flow temperature and pressure are not constant, a flow computer. specifications linearity 1 ã�â±1.0%0.5% repeatability 1 ã�â±0.25% maximum over-range 125% of flow rate for intermittent periods frequency output 0 to 1,100 hz voltage output approximately 100 mv@ 100 hz to 1.5 v (rms)@ 1,000 hz. pressure drop 0.5 psi at 100% of flow range pressure rating we manufacture flowmeters for most pressures. installation vertical or horizontal (any direction). materials of construction body: 316 l stainless steel. flanges: 316 stainless steel rotor: 431 stainless steel. rotor shaftbearings: standard: tungsten carbide v-cup cartridge frame retainer: 302 stainless steel cartridge frame: 316 l stainless steel. temperature range:meter with bearing structure of: standard: tungsten carbide: -40ã�â°f to 300ã�â°f (-40ã�â°c to 149ã�â°c). for other temperatures consult factory.
...morelpg flow meters
15,000 - 60,000 Per Piece
2 Piece(s) (MOQ)
We have come up with reliable LPG Flow Meters. The LPG Flow Meters that we offer are manufactured with the use of best quality components that impart strength and endurance. Our LPG Flow Meters provide accurate readings of the flow with an absolute ease. Our LPG Flow Meters are sophisticated and work with utmost precision. Principle of Operation LPG Flow Meters The operation of the International Gas Turbine Meter is based on the measurement of the velocity of gas.The flowing gas is accelerated and conditioned by the meter´s straightening section. The straightening vanes prepare the gas flow profile by removing undesired swirl, turbulence and asymmetry before the gas flows to the turbine wheel.The Dynamic Forces of the Flowing Fluid/Gas cause the rotor to rotate. The turbine wheel is mounted on the main shaft, with special high precision, low friction ball bearings.The turbine wheel has helical blades that have a known angle relative to the gas flow. The conditioned and accelerated gas drives the turbine wheel with an angular velocity that is proportional with the gas velocity.The rotating turbine wheel drives the index head with the eight digit mechanical counter via shafts and gears.The volume and flow rate can also be indicated electronically. A proximity probe generates a signal at each passing blade of the turbine wheel. With the device-specific K-factor and the number of pulses, the passed volume can be calculated. With the measured frequency the flow rate can be determined.The rotating turbine wheel can also generate pulses directly by proximity sensors that create a pulse for each passing turbine blade. By accumulating the pulses the total passed volume and gas flow rate can be calculated. General This is a highly accurate flow meter, approved for custody transfer measurement, equipped with electronic pulse outputs and a mechanical counter. This document explains the dimensions, ranges, performance, calibration and outputs of the instrument. It details the installation, safety requirements and material specifications. The Gas Turbine Flow Meter measures gas volume flowing through an annular passage in the meter. The flowing gas volume is totalized on a local mechanical counter. In addition, low or high frequency pulse signals are generated to infer the gas flow and volume. The indicated gas volume is the actual volume flowing through the meter at the actual temperature and pressure. The Gas Turbine Flow Meter is available in two models.The Gas Turbine Flow Meter is used for high accuracy and custody transfer applications. The Gas Turbine Flow Meter is an economically priced meter with a good accuracy.Gas TypesThe Gas Turbine Flow Meter in its standard design can be used for all non-aggressive gases, such as natural gas, methane, propane, butane, city gas and fabricated gas, air, nitrogen, etc. For aggressive gases, like sour gas, biogas and oxygen, special designs are available with Teflon coating, special lubrication or special purging. See table 1, for detailed requirements or different type of gases. Temperature Ranges As standard The Gas Turbine Flow Meter is designed to operate at temperatures between -10oC to 60oC. Special low and high temperature designs are available on request. Standard accuracy limits for Custody Transfer models are in accordance with the EC directives and many foreign regulations : ± 0.5% for 0.2 Qmax to Qmax± 0.5% for Qmin to 0.2 Qmax As an option for the Custody Transfer model the accuracy limits can be improved to : ± 0.2% for 0.2 Qmax to Qmax± 0.3% for Qmin to 0.2 Qmax These limits are valid for the meter performance in ambient air. Usually, the performance is better at high-pressure applications. On request we can offer meters according to your accuracy specification. The repeatability of the LPG Flow Meters is better than 0.1%Material of Construction: Material of Construction Gas Turbine Flow Meter Regularly Stainless Steel 316 L. Principle of Operation: As Above. Nameplate Detail: Measurement systems group.Index head and pulse transmitters: stainless steel measurement systems group make. Fully intrinsic free hazardous free, potential freeMaximum operating pressure: manufactured as per requirementRequired upstream and downstream length: as required.Lubrication system: without bearings.Lubrication before start-up: without bearings.Regular lubrication: without bearings.Volume conversion: mass flow meter direct calibration on appl.gas.Flow direction and orientation: as indicated on flow meter.Connection pressure transmitter: NA for volumetric/mass flow meter ss316 l pressure transmitter. Pressure compensated.Temperature Measurement: Temperature compensated. Warranty : One Year Warranty. 7-digit total flow displayFlow Rate 3 %1/2 digits displayProgrammableExternal battery backupProgramming lock4-20 ma OutputRS-485 Port for interfacing with computerFlow Rate, total flow one touch switching modeDigital switching outputs have LED status indicatorsFront panel environmental protection to IP65 (IP40 for rear of unit)Compact DesignSpecialized for measurement systems sensors Specifications Supply voltage : 230V ACSupply current : NAMax output load current : NAMax output load voltage : NAInternal voltage drop : NADisplay units - rate : l/min, US gal/minDisplay units â volume : liters, US gallonsRepeatability : ±0.5% FS or lessLinearity : ±1.0% FS or lessResponse time : 1 second maxTemperature range : 0 to 80oCIP rating - front panel : IP65IP rating - enclosure : IP40Weight : 245 g Flow Rates Flow Rate measurement range : NAK Factor : NA The Systems RS-485 to USB is a USB to RS485 converter. It allows easy serial port expansion without requiring IRQ, DMA, or I/O port resources. The converter allows the user to easily and economically connect RS485 devices to a host using USB. The RS485 communications standard is used by Measurement Systems Pickoff Sensor based data acquisition modules and many industrial control devices. The converter is based on a single chip USB UART for transferring serial data over the Universal Serial Bus without the need for card-slots. The converter has an internal 128 byte transmit buffer and a 384 byte receive buffer. It supports baud rates of up to 230K. External power is not required since takes its power from the bus. Connection to USB is via a 3-foot detachable cable. Connection to RS485 is thru the converters DB-9 male connector. The converter is housed in a plastic enclosure designed for rugged applications. The converter can interface RS485 modules to a host using a USB connection, when using the Measurement Systems RS-485 to USB with a module or any RS485 device that requires wiring, recommends itsâ CA-3 cable. The CA-3 is a 3-foot serial cable with a female DB-9 connector and tinned wires ready for connection to RS485. We Have Recently Developed a Portable Flow meter. The Portable Flow meter Works on the Inbuilt Battery of the Totalizer.
...moreLPG Flow Meter 03
2 Piece(s) (MOQ)
Clients can avail from us, precision engineered LPG Flow Meter. This LPG Flow Meter is manufactured with the use of latest technology ensuring accurate readings. This LPG Flow Meter is provided at economic prices.
...moreLPG Flow Meter 02
2 Piece(s) (MOQ)
Clients can avail from us, precision engineered LPG Flow Meter. This LPG Flow Meter is manufactured with the use of latest technology ensuring accurate readings. This LPG Flow Meter is provided at economic prices.
...moreLPG Flow Meter 01
2 Piece(s) (MOQ)
Clients can avail from us, precision engineered LPG Flow Meter. This LPG Flow Meter is manufactured with the use of latest technology ensuring accurate readings. This LPG Flow Meter is provided at economic prices.
...moregas mass flow meters
2 Piece(s) (MOQ)
We are the main supplier of this product.
fuel mass flow meters
2 Piece(s) (MOQ)
We are the main supplier of this product.
Flow Meters
2 Piece(s) (MOQ)
We are the main supplier of this product.
electronic mass flow meters
2 Piece(s) (MOQ)
We have a strong security system that helps us to make online transactions possible without getting worried about the security. You need to share your details with us and we make sure that the details are kept confidential. Engaged in the industry as a prominent Supplier of electronic mass flow meters, we present the finest range of products.
...moreDigital Gas Flow Meter
1 Piece(s) (MOQ)
within the working range of the meter the rotor spins proportional to the actual velocity of gaseous material flowing. a pick-up sensor produces an electrical signal as each blade crosses through its low magnetic or rf field. this signal is amplified and conditioned by a transmitter or fed directly into a ratetotalizer, and represents the actual cubic feet per minute (acfm) flowing through the meter. the k-factor is stenciled on the meter body in pulses per actual cubic feet (pacf). because gases are compressible, most people desire to measure the equivalent amount of gas corrected for the line pressure and temperature to standard cubic feet per minute (scfm at 60ã�â°f, 14.69 psia). if the flow temperature and pressure are relatively constant, then a simple correction can be calculated to shift the k-factor from pacf to pscf and a simple totalizer (measurement systems india make ) may be used. when flow temperature and pressure are not constant, a flow computer. specifications linearity 1 ã�â±1.0%0.5% repeatability 1 ã�â±0.25% maximum over-range 125% of flow rate for intermittent periods frequency output 0 to 1,100 hz voltage output approximately 100 mv@ 100 hz to 1.5 v (rms)@ 1,000 hz. pressure drop 0.5 psi at 100% of flow range pressure rating we manufacture flowmeters for most pressures. installation vertical or horizontal (any direction). materials of construction body: 316 l stainless steel. flanges: 316 stainless steel rotor: 431 stainless steel. rotor shaftbearings: standard: tungsten carbide v-cup cartridge frame retainer: 302 stainless steel cartridge frame: 316 l stainless steel. temperature range:meter with bearing structure of: for other temperatures consult factory.
...moreDifferential Pressure Flow Meters
35,000 - 65,000 Per Piece
3 Piece(s) (MOQ)
Clients can avail from us cutting-edge Differential Pressure Flow Meters. These Differential Pressure Flow Meters are made as per the international quality norms and are highly reliable. In these Differential Pressure Flow Meters, there is a turbine meter that consists of a practically friction-free rotor pivoted along the axis of the meter tube and designed in such a way that the rate of rotation of the rotor is proportional to the rate of flow of fluid through the meter. This rotational speed is sensed by means of an electric pick-off coil fitted to the outside of the meter housing. The only moving component in the meter is the rotor, and the only component subject to wear is the rotor bearing assembly. However, with careful choice of materials (e.g., tungsten carbide for bearings) the meter should be capable of operating for up to five years without failure. There are several characteristics of turbine flow meters that make them an excellent choice for some applications. The flow sensing element is very compact and light weight compared to various other technologies. This can be advantageous in applications where space is a premium. Primary Vs. Secondary Standards A primary standard calibration is one that is based on measurements of natural physical parameters (i.e., mass, distance, and time). This calibration procedure assures the best possible precision error, and through traceability, minimizes bias or systematic error. A secondary standard calibration is not based on natural, physical measurements. It often involves calibrating the user's flow meter against another flow meter, known as a "master meter," that has been calibrated itself on a primary standard. Calibration "To calibrate" means "to standardize (as a measuring instrument) by determining the deviation from a standard so as to determine the proper correction factors." There are two key elements to this definition: determining the deviation from a standard, and ascertaining the proper correction factors. Flow meters need periodic calibration. This can be done by using another calibrated meter as a reference or by using a known flow rate. Accuracy can vary over the range of the instrument and with temperature and specific weight changes in the fluid, which may all have to be taken into account. Thus, the meter should be calibrated over temperature as well as range, so that the appropriate corrections can be made to the readings. A turbine meter should be calibrated at the same kinematic viscosity at which it will be operated in service. This is true for fluid states, liquid and gas. Master Meter A master meter is a flow meter that has been calibrated to a very high degree of accuracy. Types of flow meters used as master meters include turbine meters, positive displacement meters, venturi meters, and Coriolis meters. The meter to be calibrated and the master meter are connected in series and are therefore subject to the same flow regime. To ensure consistent accurate calibration, the master meter itself must be subject to periodic recalibration Gravimetric Method This is the weight method, where the flow of liquid through the meter being calibrated is diverted into a vessel that can be weighed either continuously or after a predetermined time. The weight is usually measured with the help of load cells. The weight of the liquid is then compared with the registered reading of the flow meter being calibrated Volumetric Method In this technique, flow of liquid through the meter being calibrated is diverted into a tank of known volume. The time to displace the known volume is recorded to get the volumetric flow rate eg gallons per minute. This flow rate can then be compared to the turbine flow meter readings K-Factor âKâ is a letter used to denote the pulses per gallon factor of a flow meter. Repeatability The maximum deviation from the corresponding data points taken from repeated tests under identical conditions Positive Displacement Calibrators Some of the most dramatic improvements in flow calibrator technology involve the evolution of Positive Displacement calibrators. PD systems are Primary Standard calibrators, which take into account the varying conditions under which flow meters operate. These calibrators are able to compensate for temperature, density, viscosity and other variables that can shift a meterâs output. It utilizes a precision machined measurement chamber, or flow tube, that houses a piston. This piston acts as a moving barrier between the calibration fluid and the pressurizing media used to move the piston. Attached to the piston is a shaft that keeps the piston moving in a true path and provides the link between the piston and the translator. The translator converts the linear movement of the piston through the precision flow chamber into electrical pulses that are directly related to the displaced volume. Calibrators of this style can be directly traceable to the National Institute of Standards and Technology via water draw validation. Total accuracy of this type of calibrator is conservatively specified at 0.05%. Flow Transfer Standards Unlike primary flow standards, whose most important characteristics are their traceability to primary physical measurements (resulting in the minimization of absolute uncertainties, with less concern for usability or cost issues), the key criteria for secondary Flow Transfer Standards are portability, low cost and the ability to calibrate the flow meter in the physical piping configuration it lives in. Instead of removing flow meters from service for recalibration, FTS devices allow users to âbring the calibrator to the flow meter.â These portable, documenting field flow calibrators are intended for in-line calibration and validation of meters using the actual process conditions for gas or liquid. Advanced FTS systems incorporate hand-held electronics with built-in signal conditioners, thus eliminating bulky interface boxes and the need to carry a laptop computer into the field. High-quality Flow Transfer Standards also have the capability of measuring and correcting the influences of line pressure and temperature effects on flow. Operation of a portable Flow Transfer Standard requires that a master meter be installed in series with the flow meter under test. The readings from these instruments are compared at various flow rates or flow totals. A technician can install the master meter in the same system as the test meter, perform the calibration, and note any changes in performance. New calibration data might cause rescaling or new data points to be programmed into a flow meterâs computer to align the measurement with the current flow calibration data. Typical Calibration Techniques Most Differential Pressure Flow Meters calibration service suppliers provide a choice of calibration techniques to accommodate different applications and flow measurement requirements. One of the most common techniques is the single-viscosity calibration, which consists of running 10 evenly spaced calibration points at a specified liquid viscosity. Single-viscosity calibrations are recommended when the viscosity of the liquid being measured is constant. If a higher degree of accuracy is needed, again, the more data points taken the better defined the meter calibration curve will be Strouhal Number/Roshko Number The best, and only completely correct way to present the data for a Turbine Meter is Strouhal Number as a function of Roshko Number, i.e., through the use of two dimensionless parameters. The St vs. Ro presentation takes into account, all of the secondary effects to which the meter is sensitive. This presentation or correlation is correct for both liquids and gases. It is almost a must for gas calibrations since the density and kinematic viscosity are a function of both temperature and pressure Calibrated Differential Pressure Flow Meters Once the Differential Pressure Flow Meter is calibrated, it may still read exactly the same under the same flow conditions as it did before it was calibrated. The difference is that you will know exactly how close those values are to the true values, and you will have a formula to use to calculate the true values from the actual values read by your flow meter. You can have a correction factor obtained from calibratiob which you can apply to the flow meter readings to obtain the correct or true flow meter readings. K-factor ignores the effects of changing temperature on the meter body since the meter will change diameter when the temperature changes. The use of Strouhal Number instead of simple K-Factor will account for this temperature effect. Other DetailsPayment TermsL/C (Letter of Credit)FOB Price100000 INRPort of DispatchAt Ex.Factory Works Production Capacity1000 Units per WeekDelivery TimeImmidiate if Required
...moreDiesel Flow Meter
1 Piece(s) (MOQ)
low cost diesel flowmeters for inline applications . can be manufactured in all the sizes,temp,pressures no compromises in quality .large scale productions makes the product a negotiable rated one.the flowmeter is 100% portable and can be used for most of the purposes ..can be best option for tanker loading and unloading
...moreDiesel Flow Meters
3 Piece(s) (MOQ)
diesel flowmeter with lowest weight for custody transfer applications for decantation of tanker trucks to under ground tanks by gravity. he is looking for machine with accuracy rate 0.5%. flow meter has gravity transfer, variable flow and has robust design and is portable.
...moreCoal Gas Flow Meter
35,000 - 60,000 Per Piece
2 Piece(s) (MOQ)
Our company�s name figures in the list of renowned Manufacturers, Suppliers and Exporters of Coal Gas Flow Meter from Maharashtra. The Coal Gas Flowmeter we make available is microprocessor controlled and provides reliable and accurate gas mass flow measurement. Owing to our brilliant logistics network, we are capable of delivering bulk orders of the Coal Gas Flowmeter within the promised time frame. Details The model MFML-1000 series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate gas mass flow measurement Specially For Coal gas Applications where Tar and Moisture is Present and The Temperature May be Higher Than Normal Applications Than 60 Degree Celsius, which is based on constant temperature differential technology for air and other process gases in range from 0 � 30 NMPS. Because neither temperature nor pressure measurement are required. MFML-1000 series reduces installation cost and vastly improves system accuracy. The meter is easily installed or retrofitted with minimum down time and provides superior long term process reproducibility and easy serviceability. MFML-1000 Insertion type flow meters are available in probe sizes from 4� to 50 � with either compression fitting or flange connection. The transmitter provides a 4-20 mA linear output signal and optionally an RS485 serialized digital output signal. Other analog outputs are also available. Programmable Logic Controller Is Used which Shows Flow rate, Total Flow, Velocity, MMBTU and Voltage Signal Received From The Transmitter/Thermal Flowmeter. There is a Provision Specially Offered to Display The MMBTU Values which are Usually Required .The Calorific Values Can be Programmed as Required and as Per Known MFML-1000 series flow meter utilizes a constant temperature differential (dT) technology. The sensor has two elements. The reference RTD measures the gas temperature. The electronics heats the heated element above the gas temperature. It is the job of the electronics to maintain a constant dT between the gas temperature and the heated element. As the mass flow increases, the increased number of gas molecules removes more heat from the heated element. The electronics senses this temperature reduction and adds additional power in order to maintain a constant dT. The amount of power delivered to the heated element, therefore, is just proportional to the mass flow rate.
Voltage : 110V, 380V, 440V
Application : Industrial, Residential
Operating Temperature : 10-50D/C, 50-100D/C
Driven Type : Electric
Warrenty : 2 Years
...morebiogas mass flow meters
2 Piece(s) (MOQ)
Ours is a well-established organization based in Pune(India) and in proximity to valuable resources. The offered assortment of products is sternly checked, examined by the quality experts to maintain the set industrial standards.
...moreBiogas Flow Meters
10,000 - 25,000 Per Piece
2 Piece(s) (MOQ)
We are instrumental in offering the finest range of Biogas Flow Meters. Our Biogas Flow Meters are known for higher accuracy in measuring flow. These Biogas Flow Meters are fabricated with the use of high quality components to ensure flawless functioning. Our Biogas Flow Meters can be obtained at the market leading prices. Characteristics Flow meters for natural pressuresInbuilt battery powered totaliser which makes it a portable oneFor almost from 3mm to 12 inchBiogas flow meter works for scrubbed biogas which contains CO2, moisture, and H2SElectronics displayHigh accuracyFull stainless steel flow meterPatented designVertical and horizontal both mounting availableHazardous proof certifications, calibration certifications with each flow meter Features Electronics ReadoutsSpecailly Caliberated on Biogas itselfGovt. certifications or comp. authorityData portablity for data storage facilityFor all sizes & all low pressuresGurantee of one year Applications Including measurementPlant cost alocationEnergy consumption/conservationAccounting for various purposesDistribution & other vast purposesGas productionPrimary metalsFertilizer Manufacturing & vehicale fueling Typical Gases Measured AcetyleneCarbon DioxideHydrogenNitrous OxideAirCarbon MonoxideMethaneOxygenAmmoniaEthaneNatural GasPropaneArgonHeliumNitrogenSulfur Dioxide SpecificationsAccuracyTypically ± 5% (improved accuracy available as an option)Temperature RangeAs per RequirementPressure RatingsANSI flanges 150# through 2500#. DIN flanges upon request.Over range150% of maximum flow (intermittently)End FittingsAs per Requirements Construction MaterialsBody316 Stainless steel standardRotorSS316LBearingsSelf-lubricated ceramic hybrid ball bearingsFlangsAs per RequirementsSpecialCustom Materials of Construction available upon request
...moreAir Flow Meter
1 Piece(s) (MOQ)
within the working range of the meter the rotor spins proportional to the actual velocity of gaseous material flowing. a pick-up coil produces an electrical signal as each blade crosses through its low magnetic or rf field. this signal is amplified and conditioned by a transmitter or fed directly into a ratetotalizer, and represents the actual cubic feet per minute (acfm) flowing through the meter. the k-factor is stenciled on the meter body in pulses per actual cubic feet (pacf). because gases are compressible, most people desire to measure the equivalent amount of gas corrected for the line pressure and temperature to standard cubic feet per minute (scfm at 60â°f, 14.69 psia). if the flow temperature and pressure are relatively constant, then a simple correction can be calculated to shift the k-factor from pacf to pscf and a simple totalizer (measurement systems india make ) may be used. when flow temperature and pressure are not constant, a flow computer. specifications linearity 1 â±1.0%0.5% repeatability 1 â±0.25% maximum over-range 125% of flow rate for intermittent periods frequency output 0 to 1,100 hz voltage output approximately 100 mv@ 100 hz to 1.5 v (rms)@ 1,000 hz. pressure drop 0.5 psi at 100% of flow range pressure rating we manufacture flowmeters for most pressures. installation vertical or horizontal (any direction). materials of construction body: 316 l stainless steel. flanges: 316 stainless steel rotor: 431 stainless steel. rotor shaftbearings: standard: tungsten carbide v-cup cartridge frame retainer: 302 stainless steel cartridge frame: 316 l stainless steel. temperature range:meter with bearing structure of: standard: tungsten carbide: -40â°f to 300â°f (-40â°c to 149â°c). for other temperatures consult factory.
...moreOpening Hours