Oil Filter Dealers in Warje, Pune

(14 products available)
  • hydraulic Oil Filter Paper & collectors

    hydraulic Oil Filter Paper & collectors

    2,000 - 4,500 Per Pack

    • Type: Paper, Oil filtration
    • Shelf Life: 2years
    • Color: White

    We are engaged in the manufacturing, supplying and exporting of high quality hydraulic Oil Machine Filter Paper. These Oil Filter Papers are highly demanded in the market due to their cost effectiveness and longevity. Availability : Prefilters ;Cartridge filters feature an Acrylic Fiber-Phenolic resin Cellulose Fibers-Melamine Resin construction.Produce an extremely rigid pore structureThis construction allows the filter to withstand extreme viscosities and temperature without compression or collapse.A true graded density construction allows complete utilization of the filter's depth, with coarse particles captured in the outer zones and finer particles captured in the inner qualifying zone.Both wire mesh and paper mesh also available with various sizes as per customer requirements.Collector Paper :Cellulose filter paper (collector paper) for electrostatic oil purifier as per models and if required it can be supplied by us as per customer requirement. Features : Highly absorbentOptimum qualityAnti-tear Applications : Oil refineries (for removing impurities from oil)steel industryplasti molding

    more..
  • Automatic Gen-Next Oil Filtration

    Automatic Gen-Next Oil Filtration

    1,299 Per Piece

    • Brand Name: GEN-NEXT
    • Automation Grade: Automatic
    • Material: Paper Core
    more..
  • Best Deals from Oil Filters

  • Mesh Belt Oil Filter

    Mesh Belt Oil Filter

    Get Price Quote

    Structural Features: Automatic slag removal, continuous, easy to clean, safe operation, reliable Technical Features: Through the centrifugal pump to high temperature frying oil suction filter, network with automatic operation, when the oil reaches the limiting position, suction pump automatically start, through the level switching regulators, the oil in the filter surface is always stable position, the filtering net the frying oil in the frying process of particulate impurities, carbide and other harmful substances effectively filter, and in mesh belt drive, in the export is automatic scraper removed The machine adopts stainless steel and the material manufacture for food industry Adopt the stainless steel filter mesh belt, and filter the pore to reach 60 microns Adopt the high efficiency circulating centrifugal pump and the import drive motor, guarantee the work flow, no trouble The most advanced level limit switch, ensure the circulation filtration and stability, no overflow oil The most convenient and quick installation, cleaning way, all the pipeline connection all the use of fast joint All the piping interface symmetrical design, can be installed according to the spot situation. Maximum space savings. Technical Parameters: Model - PVG-WYJ-800 Belt width - 780 mm Filtration porosity - 60 μm Rate of flow - 10 Th Total power - 4.6 kw Pump inlet height - 295 mm Pump outlet height - 421 mm Inlet pipe diameter - DN 40 Outlet pipe diameter - DN 32 Dimensions - 1810 x 1570 x 1260 mm filtration fabric - 304 stainless steel Filtration mode - Continuous filtration and synchronous operation of frying machine

    more..
  • centrifugal oil filters

    centrifugal oil filters

    Get Price Quote

    Centrifugal Oil Cleaner operates on the Reaction turbine principle. Oil enters the Centrifuge under pressure and passes into the rotor thru hollow rotor shaft. The oil pressure and flow is converted in rotational energy as the oil escapes through the jets, producing speed up to 7000 RPM & above. The resultant Centrifugal force removes dirt from the engine oil depositing it on the inner wall of rotor in a dense cake form. Clean oil drains back directly to the tank.

    more..
  • Oil Filtration Plant

    Oil Filtration Plant

    Get Price Quote

    OIL FILTRATION PLANTS CAN BE SUCCESSFULLY MODIFIED & AUTOMATED FOR VARIABLE FLOW RATE. A brief description is given for your reference.   INLET & OUTLET PUMPS : The pump will be driven by suitable sized AC drive to control the flow rate. By using these settings we can control the flow rate from i.e. If Plant is 6000 LPH then it will vary from 1000 LPH to 6000 LPH.   HEATER TANK : It is also necessary to select proper heat output for variable flow rates. This will avoid localized heating of oil for small flow rates.This section will incorporate PLC which will control the heaters.PLC will be used for control of heater groups, once certain flow rate has been selected, heaters will be configured automatically to suit that flow rate. This control panel will be designed for reliable & trouble free operation.By using the above system the major benefit is to have a single machine instead of different models for different capacities. In this case, flow rate can be kept variable from 1000 LPH to 6000 LPH. Power saving of 30% can be achievable by using this system as compared with traditional oil filter system designs.   OPERATIONAL & PROCESS AUTOMATION Press 'START' to start the oil filtration process. All airing valves, oil inlet & outlet valve will close. The rotary vacuum pump will start to achieve coarse vacuum. After achieving coarse vacuum level, which the 'Vacuum Switch' will sense. After achieve the desired level of fine vacuum in the plant, oil inlet valve & intermediate valve will open and the oil inflow will start due to vacuum inside the plant. The flow switch provided in the suction line of the plant will sense the oil flow & that signal will start the oil inlet pump. In case, the incoming oil flow is not there, HMI on the control panel will display 'LOSS OF OIL', with annunciation. One pressure release valve, provided across the inlet pump will control the excessive pressure rise in the plant. As oil is filled in the degassing chamber, the high level float switch will operate & that will put 'OFF' the inlet pump & start the outlet pump. The starting signal to the outlet pump will open the outlet valve. As the oil level in the degassing chamber comes down, the high level float switch will start the inlet pump, again. Thus the oil circulation through the filtration plant will start. After the continuous oil flow through the plant, the heaters will be 'ON'. Temperature of oil will be controlled by TIC (Temperature Indicating Controller) & one safety thermostat will control the accidental temperature rise. Thus the hot oil circulation through filters & degassing chamber will start resulting in the effective separation of solid impurities as well as dissolved moisture & gases from the oil. During the filtration process, the necessary interlocks provided will avoid malfunctioning of the plant, like   1. High level float switch will stop the inlet pump, to avoid flooding of the degassing chamber. 2. Unless the inlet pump is 'ON' the heaters will not be energized. 3. Low level float switch will stop the outlet pump to avoid dry running of the pump During the filtration process, the moisture meter, installed in the inlet line, will display the moisture content in PPM, continuously, on it's indicator, on the control panel. Once the desired PPM (moisture) content is achieved, the moisture meter installed in the inlet line, will shut down the plant, automatically. This plant will also run with Manual Interference means with Manual Operation.

    more..
  • hydraulic oil filtration equipment

    hydraulic oil filtration equipment

    Get Price Quote

    hydraulic oil filtration equipment We are the leading manufacturers of high quality industrial micro filters and filtration systems in India. We believe that our expertise in this particular field should be made available to our customers in order to assist them in their quest for manufacturing excellence.

    more..
  • Mobile Oil Filtration Plant

    Mobile Oil Filtration Plant

    Get Price Quote

    During its operation of generating, transmitting and distributing power transformers give out heat which is absorbed by insulating oils. This oil has a tendency to absorb moisture from windings which leads to gradual deterioration of dielectric strength. Our filtration systems provide economical and efficient methods of purifying this lubricant. The unit consists of:   Filter Unit, Indirect system of Oil Heating, Vacuum Dehydration / degasification Unit Condenser and condensate receiver Feed and delivery pump Piping & Valves Control Panel   Components of Plant The filter unit is a coarse strainer with a wire mesh filter element for retaining solid particles and a powerful magnet for retaining magnetic particles. It has round filter paper discs held under spring compression. Specially designed heaters with low watt density heat the auxiliary heating oil, which in turn heats the transformer oil maintaining a temperature of 70-80 C. The cylindrical external pressure vessel is fitted with various shallow drip trays and a specially designed spray pipe to increase surface area. The vapor from dehydration chamber is condensed in a condensate receiver of welded M. S. construction. There are feed and delivery pump of rotary gear type coupled directly with motors. Water Separator Collect the water produced. A centralized control panel has indicators for all electrical devices. Imported thermostat Thermometer for measuring temperature Pressure & Vacuum gauges Flow control indicator Electronic Float Control Electrical instruments, voltometers and ammeters Electrical overloads and overload releases for safety of motors.    

    more..
  • OIL FILTRATION PLANTS

    OIL FILTRATION PLANTS

    Get Price Quote

    OIL FILTRATION PLANTS CAN BE SUCCESSFULLY MODIFIED & AUTOMATED FOR VARIABLE FLOW RATE. A brief description is given for your reference.   INLET & OUTLET PUMPS : The pump will be driven by suitable sized AC drive to control the flow rate. By using these settings we can control the flow rate from i.e. If Plant is 6000 LPH then it will vary from 1000 LPH to 6000 LPH. HEATER TANK : It is also necessary to select proper heat output for variable flow rates. This will avoid localized heating of oil for small flow rates.This section will incorporate PLC which will control the heaters.PLC will be used for control of heater groups, once certain flow rate has been selected, heaters will be configured automatically to suit that flow rate. This control panel will be designed for reliable & trouble free operation.By using the above system the major benefit is to have a single machine instead of different models for different capacities. In this case, flow rate can be kept variable from 1000 LPH to 6000 LPH. Power saving of 30% can be achievable by using this system as compared with traditional oil filter system designs.   OPERATIONAL & PROCESS AUTOMATION Press 'START' to start the oil filtration process. All airing valves, oil inlet & outlet valve will close. The rotary vacuum pump will start to achieve coarse vacuum. After achieving coarse vacuum level, which the 'Vacuum Switch' will sense. After achieve the desired level of fine vacuum in the plant, oil inlet valve & intermediate valve will open and the oil inflow will start due to vacuum inside the plant. The flow switch provided in the suction line of the plant will sense the oil flow & that signal will start the oil inlet pump. In case, the incoming oil flow is not there, HMI on the control panel will display 'LOSS OF OIL', with annunciation. One pressure release valve, provided across the inlet pump will control the excessive pressure rise in the plant. As oil is filled in the degassing chamber, the high level float switch will operate & that will put 'OFF' the inlet pump & start the outlet pump. The starting signal to the outlet pump will open the outlet valve. As the oil level in the degassing chamber comes down, the high level float switch will start the inlet pump, again. Thus the oil circulation through the filtration plant will start. After the continuous oil flow through the plant, the heaters will be 'ON'. Temperature of oil will be controlled by TIC (Temperature Indicating Controller) & one safety thermostat will control the accidental temperature rise. Thus the hot oil circulation through filters & degassing chamber will start resulting in the effective separation of solid impurities as well as dissolved moisture & gases from the oil. During the filtration process, the necessary interlocks provided will avoid malfunctioning of the plant, like   1. High level float switch will stop the inlet pump, to avoid flooding of the degassing chamber. 2. Unless the inlet pump is 'ON' the heaters will not be energized. 3. Low level float switch will stop the outlet pump to avoid dry running of the pump During the filtration process, the moisture meter, installed in the inlet line, will display the moisture content in PPM, continuously, on it's indicator, on the control panel. Once the desired PPM (moisture) content is achieved, the moisture meter installed in the inlet line, will shut down the plant, automatically. This plant will also run with Manual Interference means with Manual Operation.

    more..
  • Hydraulic Filter for Oil Recovery

    Hydraulic Filter for Oil Recovery

    Get Price Quote

    Hydraulic Filter for Oil Recovery, Cabinet Type Front Loading Cleaning Machine

    more..
  • Oil Filters

    Get Price Quote

    Oil Filters, seedless dry grapes, Electric Motors, Pumps

    more..
  • Oil Removal Filters

    Oil Removal Filters

    Get Price Quote

    Oil Removal Filters, Air Valves, borosilicate micro class filters

    more..
  • Oil Filters

    Get Price Quote

    Oil Filters

    more..
  • Edible Oil Filter Papers

    Get Price Quote

    Edible Oil Filter Papers, Scraper Conveyor, Paper Band Filter

    more..
  • Electrostatic Oil Filters

    Get Price Quote

    Electrostatic Oil Filters, Electrostatic Oil Cleaner, Vacuum Dehydration Unit

    more..
Filter by Locality
top