water motor sensor
We are working with a group of professionals who make special emphasis on the products packaging and ensure that the material is procured from the reliable sources only. In order to ensure product compliance with stated quality norms, we conduct several tests at several stages. Details : Power ON LED : It indicates the power supply to the unit. Motor ON LED: It indicates the motor ON and Off Condition Tank Level Indication LED: Two level visual indications – 25% (Low Level), 75% (Tank full level). Motor will automatically switch ON when the water level in the tank is low and automatically switch OFF within 1 second when the tank becomes full. Manual Mode: Helps to switch ON the motor manually. In this mode, the motor will be running till the tank will be full . The product having special features of two relays for submersible Pump. one for starting capacitor and other for running capacitor. The three sensor electrode indicates the water level of the tank. Helps in preventing overflow of water from the overhead tank Input Voltage- 230V to 275 V(AC) Output Contacts-2 NO Long Life Easy to install
...moreMicrocontroller Based Water Level Controller
We are working with a group of professionals who make special emphasis on the products packaging and ensure that the material is procured from the reliable sources only. In order to ensure product compliance with stated quality norms, we conduct several tests at several stages. Details : Power ON LED : It indicates the power supply to the unit. Motor ON LED: It indicates the motor ON and Off Condition Tank Level Indication LED: Two level visual indications – 25% (Low Level), 75% (Tank full level). Motor will automatically switch ON when the water level in the tank is low and automatically switch OFF within 1 second when the tank becomes full. Manual Mode: Helps to switch ON the motor manually. In this mode, the motor will be running till the tank will be full . The product having special features of two relays for submersible Pump. one for starting capacitor and other for running capacitor. The three sensor electrode indicates the water level of the tank. Helps in preventing overflow of water from the overhead tank Input Voltage- 230V to 275 V(AC) Output Contacts-2 NO Long Life Easy to install Application: Automatic Microcontroller Based Water Level Controller is of much used in metro cities, bungalows, industries, hospitals and in luxurious apartments and homes. Use of this product saves water, saves electricity and saves time. Useful in case of bore well to tank set up. Booster Pump Control Panels Textile Machineries Garment Machineries Water Distribution Pumps House Submersible Pump Control Panel Package Boiler in Sugar Factory Heat Exchanger Steam Generators Advanced Microcontroller Based Water Level Controller (Auto Change Over) Dual pump operation. Control Sump (open well) pump as well as Bore well pump with automatic changeover technology To suit where both the motors are used to pump water to Common overhead tank (Single Tank) Three modes of operation. OpenWell (sump) mode Bore well mode. Automatic Change Over Mode (Dual Mode) Four stage water level indicator for over head tank, Three stage water level of sump Water flow indication(Running Line), Over and under voltage level indication and protection By Pass facility in case for direct operation. Manual Soft Touch ON / OFF Support both Single Phase & Three Phase connection Easy integration with control panel Basic Microcontroller Based Water Level Controller - WLC-01Single tank - 2 level control relay Indications – Empty Full Motor ON/OFF Control Switches Auto/ Manual Switch Relays 2 relay output. Relay Rating - 10A at 240V Sensors 3 Sensor stainless steel PVC coated Protection Type Dryrun Compatibility : Single phase starter panel Compatible Three phase starter panel Compatible Microcontroller Based Water Level Controller for Upper Tank and Lower Tank (SUMP) - WLC-02 Dual tank - 2 level control relay Indications – Empty Over Head Tank Full Over Head Tank Empty Sump Motor ON/OFF Control Switches Auto/ Manual Switch Relays 2 relay output. Relay Rating - 10A at 240V Sensors 4 Sensor stainless steel PVC coated Protection Type Dryrun Compatibility Single phase starter panel Compatible Three phase starter panel Compatible Online Microcontroller Based Water Level Controller - WLC-03 Dual tank - 2 level control relay Indications – Empty Over Head Tank Full Over Head Tank Empty Sump Motor ON/OFF Control Switches Auto/ Manual Switch Relays 2 relay output. Relay Rating - 10A at 240V Sensors 4 Sensor stainless steel PVC coated Protection Type Dryrun Compatibility Single phase starter panel Compatible Three phase starter panel Compatible Basic Microcontroller Based Water Level Controller Reverse Type- WLC-04Single tank - 2 level control relay When tanks gets full pump gets ON to siphon the water out of the tank and then tanks gets empty pumps gets OFFIndications – Empty Full Motor ON/OFF Control Switches Auto/ Manual Switch Relays 2 relay output. Relay Rating - 10A at 240V Sensors 3 Sensor stainless steel PVC coated Protection Type Dryrun Compatibility Single phase starter panel Compatible Three phase starter panel Compatible
...moretimer motor
On and Off according to time Field configuration of times zones through soft touch key pads with Password protection. To set On time and off time up to 99 hours Bright backlit LCD for display the time and date and configuration settings Bright LED indicators Input voltage range: 130V to 270 V A.C, 5060 Hz User friendly operations 10 A Relay with 1 NO2 NO Low Power Consumption Designed with Surface Mounted Technology for high reliability Wall Mounted Casing Metal sheet Cabinet
...morestainless steel sensor
The Stainless Steel Sensor, provided by us, is acclaimed for its make. We are backed by modern transit facilities and thus while located in Pune(India), we are able to reach any destination easily. Keeping in consideration the latest standards, we are involved in supplying only high quality Stainless Steel Sensor at reasonable prices.
...moreSingle Phase Preventer
We support credit cards, purchase cards, PIN-less debit cards, bank account transfers for your utmost convenience. We have database that is maintained by the financial experts; they make sure that the transactions are made keeping all the details of the clients confidential. Stay rest assured for the products that we offer as they will remain damage free. For this, we make use of only premium packaging material for the packing Key features: Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Phase Sequence and Phase Missing display on LCD
...moreSchool Bell Timer
We offer secured online and offline payment processing methods. The transaction, done through online mode, is instantly forwarded to the payment system. We also accept bank account transfers, cash payments, etc. The company is acknowledged as a reliable name based in Pune(India) and offering products to diverse locations. Features: On and Off according to time Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Multiple time zone for on and off the load Max. 30 Programmable events per day. 20 user programmable holiday dates. 10 user programmable holiday date ranges. Programmable event ON time duration. Bypass mode for manual operation. Bright backlit LCD for display the time and date and configuration settings. Bright LED indicators Input voltage range: 130V to 270 V A.C, 50/60 Hz User friendly operations 10 A Relay with 1 NO Low Power Consumption Designed with Surface Mounted Technology for high reliability Wall Mounted Casing Metal sheet Cabinet Applications: Developed mainly for Scholl Bell ON/OFF in pre-scheduled manner and at accurate time with taking care of holidays. Factory sirens, Office Tea time/Lunch time Bells control in pre-scheduled manner. Water Irrigation System (Sprinkler) control in pre-scheduled manner. Home Appliance control at pre-scheduled time mainly for: Water Heater, Geyser. Washing Machine. Air Conditioner (AC)Control.
...moreProgrammable Timer Switch
We support credit cards, purchase cards, PIN-less debit cards, bank account transfers for your utmost convenience. We have database that is maintained by the financial experts; they make sure that the transactions are made keeping all the details of the clients confidential. Stay rest assured for the products that we offer as they will remain damage free. For this, we make use of only premium packaging material for the packing Key features: Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Phase Sequence and Phase Missing display on LCD
...moreprogrammable timer
one can stay assured for safe deliveries as we make use of premium material for packaging the lot. Also, we make sure that the material is sourced from the trusted places only. Owing to our sound quality system, we are capable of carrying out strict quality analysis of the product basket.Field configuration of times zones through soft touch key pads with Password protection.
...moreProgrammable switches
Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Phase Sequence and Phase Missing display on LCD Under voltage and over voltage protection Under current and over current protection
...moreprogrammable digital timer
With us, one can stay assured for safe deliveries as we make use of premium material for packaging the lot. Also, we make sure that the material is sourced from the trusted places only. Owing to our sound quality system, we are capable of carrying out strict quality analysis of the product basket. Key features : Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for
...moreOnline Sensor
The Online Sensor, provided by us, is acclaimed for its make. Our organization is graded amidst advanced traders of the product in Pune(India) as well as diverse marketplaces. With thorough and deep quality analysis, we deliver the best in class product range.
...more3 Phase Motor Protector With Programmable Timer
We support credit cards, purchase cards, PIN-less debit cards, bank account transfers for your utmost convenience. We have database that is maintained by the financial experts; they make sure that the transactions are made keeping all the details of the clients confidential. Stay rest assured for the products that we offer as they will remain damage free. For this, we make use of only premium packaging material for the packing Key features: Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Phase Sequence and Phase Missing display on LCD Under voltage and over voltage protection Under current and over current protection Bright LED indicators 16 x2 Character LCD with bright LED backlight 10 A Relay with 1 NO Bypass Facility Wide Voltage Operation 190V AC to 270V AC, 50Hz Low Power Consumption Designed with Surface Mounted Technology for high reliability Reduced cost and commissioning time with protection, monitoring and control in a single device MPS With Programmable Timer Under Voltage & Over Voltage Protection Under Current & Over Current Protection Earth Fault Dry Run protection Programmable Timer with time memory backup Time Totalizer-For recording total On time Instantaneous Power Measurement-kW Cumulative Active Energy kWh Water Level Controller Temperature Sensor-For detecting overheating of motor Single Phase Preventer Phase Reverse Protection Programmable Timer with the memory Backup 16*2 Character LCD Display MPS With LCD Under Voltage & Over Voltage Protection Under Current & Over Current Protection Earth Fault Temperature Sensor-For detecting overheating of Motor Single Phase Preventer Phase Reverse 16*2 Character LCD Display MPS (Blind) Under Current & Over Current Protection Earth Fault Dry Run protection Temperature Sensor-For detecting overheating of motor Single Phase Preventer Phase Reverse
...moreMotor Protector
Power ON LED : It indicates the power supply to the unit. Motor ON LED: It indicates the motor ON and Off Condition Tank Level Indication LED: Two level visual indications – 25% (Low Level), 75% (Tank full level). Motor will automatically switch ON when the water level in the tank is low and automatically switch OFF within 1 second when the tank becomes full. Manual Mode: Helps to switch ON the motor manually. In this mode, the motor will be running till the tank will be full . The product having special features of two relays for submersible Pump. one for starting capacitor and other for running capacitor. The three sensor electrode indicates the water level of the tank. Helps in preventing overflow of water from the overhead tank Input Voltage- 230V to 275 V(AC) Output Contacts-2 NO Long Life Easy to install
...moreSmart Switch With Motion Sensor
Based in Pune(India), our organization is involved for years in supplying the finest grade of Smart Switch With Motion Sensor in the industry. We package the entire range of products with industrial-grade wrapping supplies that are environment friendly and safe. Furthermore, the packaging is sturdy to protect against damage and to make sure the product is kept quality assured. Key features : Voltage -200V – 280V AC, 50Hz Output - 2 Kwatt load of Fluorescent Tube Light, CFL, Filament Bulb or any heavy load Reach -10 meters Angle of Coverage -102° Horizontal, 92° Vertical Compact Design & easy installation Load will get off if no motion is detected continuously for 5 minutes Enhances life of Lamps & load by using Zero Crossing Switching Applications- Room & Hotel Lighting, Car Parking & Garden Lighting, Intruder detector with light & Siren etc. Smart Switch with Motion Sensor for Air Conditioner Voltage - 200V - 280V AC, 50Hz Output - 4000W load of 1.5 Ton AC Reach - 10 meters Angle of Coverage - 102° Horizontal, 92° Vertical Compact Design & easy installation Load will get off if no motion is detected continuously for 15 / 30 /45 minutes Enhances life of Lamps & load by using Zero Crossing Switching Applications- Conference room, auditorium.
...moreIcd timer
With us, one can stay assured for safe deliveries as we make use of premium material for packaging the lot. Also, we make sure that the material is sourced from the trusted places only. Owing to our sound quality system, we are capable of carrying out strict quality analysis of the product basket. Key features : Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Phase Sequence and Phase Missing display on LCD Under voltage and over voltage protection Under current and over current protection
...moreFloat V Sensor
The Float V Sensor, provided by us, is acclaimed for its make. Our packing system is systematized in such a manner that we can handle even bulk packaging with ease. Moreover, our packing experts take care of the customized as well as standard packing demands of the clients. Our range is manufactured strictly as per the globally accepted norms, thus, you can rely on us completely.
...moreFloat H Sensor
The Float H Sensor, provided by us, is acclaimed for its make. We have a good rapport with the prominent e-commerce merchants who provide us a secure payment gateway. With this, we guarantee instant and hassle free transactions. Our organization has a wide supply network, which enables us to serve buyers IN Pune(India) and/ or anywhere.
...moredry run preventer
Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Phase Sequence and Phase Missing display on LCD Under voltage and over voltage protection Under current and over current protection
...moreDigital Programmable Timer
With us, one can stay assured for safe deliveries as we make use of premium material for packaging the lot. Also, we make sure that the material is sourced from the trusted places only. Owing to our sound quality system, we are capable of carrying out strict quality analysis of the product basket. Key features : Protection against Phase Missing & Phase Reversal within 2 sec Multiple Time Zones Advanced Software based Digital Timer with missed time (due to blackout) operation e.g. if the ON TIME is 06:00 hrs and OFF TIME is 09:00 hrs and suppose there is no power in between 06:00 hrs and 08:00 hrs, the pump will remain on for the missing time i.e. pump will be on from 08:00 hrs to 11:00 hrs. Field configuration of times zones through soft touch key pads with Password protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 years Phase Sequence and Phase Missing display on LCD Under voltage and over voltage protection Under current and over current protection Bright LED indicators 16 x2 Character LCD with bright LED backlight 10 A Relay with 1 NO Bypass Facility Wide Voltage Operation 190V AC to 270V AC, 50Hz Low Power Consumption Designed with Surface Mounted Technology for high reliability Reduced cost and commissioning time with protection, monitoring and control in a single device Specifications On and Off according to time Field configuration of times zones through soft touch key pads with Passwor protection. Battery based Real Time Clock as against capacitor based for nonstop operation for 2 Years. Multiple time zone for on and off the load. Bright backlit LCD for display the time and date and configuration settings. Bright LED indicators 10 a Relay with 1 NO Low Power Consumption Input voltage range : 130V to 270V A.C, 50/60 Hz Designed with Surface Mounted Technology for high reliability Wall Mounted Casting Metal sheet Cabinet User friendly operations Designed & Mfd. In India to suit Indian power conditions Applications : Street Light, Garden Lights, Basement Lights, Staircase Lights, Parking Lights, Lights in Lobbies & Corridors, Hoarding Lights, any electrical load, On-Off, Pump On & Off, School bell, Submersible Pumps On-Off.
...moreCyclic Timer
Key features : On and Off according to time Field configuration of times zones through soft touch key pads with Password protection. To set On time and off time up to 99 hours Bright backlit LCD for display the time and date and configuration settings Bright LED indicators Input voltage range: 130V to 270 V A.C, 50/60 Hz User friendly operations 10 A Relay with 1 NO/2 NO Low Power Consumption Designed with Surface Mounted Technology for high reliability Wall Mounted Casing Metal sheet Cabinet Applications: Generator Control Panels Engine Control Panels Compressor Panels. MCC SPM control Panels Automation Panel Suitable for Industrial Washing Machines for Forward & Reverse Motion Control of Agitator Motor with selectable Pause time delay. Hence provided with separate output contacts for alternate ON delay cycle with intermediate pause time. Industrial Washing Machine Control panel.
...morebooster pump controllers
e are working with a group of professionals who make special emphasis on the products packaging and ensure that the material is procured from the reliable sources only. In order to ensure product compliance with stated quality norms, we conduct several tests at several stages. Details : Power ON LED : It indicates the power supply to the unit. Motor ON LED: It indicates the motor ON and Off Condition Tank Level Indication LED: Two level visual indications – 25% (Low Level), 75% (Tank full level). Motor will automatically switch ON when the water level in the tank is low and automatically switch OFF within 1 second when the tank becomes full. Manual Mode: Helps to switch ON the motor manually. In this mode, the motor will be running till the tank will be full . The product having special features of two relays for submersible Pump. one for starting capacitor and other for running capacitor. The three sensor electrode indicates the water level of the tank. Helps in preventing overflow of water from the overhead tank Input Voltage- 230V to 275 V(AC) Output Contacts-2 NO Long Life Easy to install
...moreAdvanced Water Level Controller
AWLC 01- Dual Motor Change over Advanced Water level Controller (Auto Change over) Dual Pump operation Control Sump (open well) pump as well as bore well pump with automatic changeover technology To suit where both the motors are used to pump water to Common overhead tank (Single Tank) Three Modes of operation. Open Well (sump) mode Bore well mode. Automatic Change Over Mode (Dual Mode) Four stage water level indicator for over head tank, Three stage water level of sump Water flow indication(Running Line), Over and under voltage level indication and protection By Pass facility in case for direct operation. Manual Soft Touch ON / OFF Support both Single Phase & Three Phase connection Easy integration with control panel Open Well (sump) mode When water in the sump tank gets below foot value level or the over head tank gets full, it automatically switch off the openwell pump to prevent electrical power loss , water wastage and dry run. Borewell mode When the water in the overhead tanks gets full , it automatically switch off the submersible pump to prevent water wastage and electrical wastage. And it has also feature to prevent dryrun incase there is no water in bore to prevent submersible motor damage. Buzzer and visual indication is provided for dry run.Automatic Changeover mode (Dual Mode) When there is water in the sump the system works on sump mode, when the Water in the sump tank gets below foot value Level it automatically switch over to the Bore well Mode. If the water gets filled in the sump tank the system Resumes back to Sump Mode. This system is suitable where both sump motor & bore motor are used to pump water to a common overhead tank. The system every time checks for available of water in the sump and controls sump motor as first choice. If and when sump becomes dry, the system will automatically changeover to bore well motor. The system can be upgraded into “Multi-tank control system” to maintaiin water level in several overhead tanks.
...morepcb designing services
For all those who are looking out for the most trusted PCB Designing Services, can contact us. We offer the best deal and ideal solutions.
...moreEmbedded Product Designing Services
Our company is recognized as one of the proficient Service Providers involved in rendering one of a kind Embedded Product Designing Services.
...moreBe first to Rate
Rate This