water heater controller
1) Modbus RTU Protocol support over RS-485 Electrical Standard2) GSM supportSupply Voltage: 230 VAC +- 15 % Display : LCD 2x16 with Back light Input :1).Temp Sensors 3 Nos b). Inlet Temperature. c). water temperature. d). ambient temperature. 2). Potential free input HP / LP for Compressor 3). Current input FROM CT for Pump 4). Potential free input for Dry Run (Flow) nput : 1) Temp Sensors 3 Nos. a) Inlet Temperature.b) Water temperature.c) Ambient temperature.2) Potential free input HP / LP for Compressor 3) Current input FROM CT for Pump 4) Potential free input for Dry Run (Flow) Output :Relay for Compressor(30 amp)Relay for Solenoid (7 Amp)Relay for Pump (7 Amp)Relay for Fan (7 Amp) :
...moreVoltage Scanner
Protection of 3 Phase devices against Over voltage, Under voltage,Single Phasing, Reverse Phasing & unbalance supply are one of the major issue in electrical systems. For safe running of 3-phase devices, special protections that keep a continuous watch on supply conditions are very essential. The major cause of maximum load burn-out is overloading which occurs due to unbalance supply, Single Phasing & Reverse Phasing conditions. Scanner detects such Conditions & protect the load from burn out. 'PROTON's Scanner' offer above protections along with 3 digit display showing R-Y,Y-B,BR voltages in scanning mode with precise accuracy. LOW/HIGH voltage tripping to ensure trouble free running of 3-phase Loads. Mounting: Door Mounting Weight: 470 grams. Dimension: 96(W) x 96(H) x 53(D) Cutout: 92(L) mm x 92(W)mm Connecting Terminals: Terminals are from backward Indication:1) supply Healthy -green LED 2) Voltage High -Red LED 3) Voltage Low -Red LED 4) Single phase or Voltage Unbalanced -Red LED 5) Reverse phase, sequence -Red LED
...moreVoltage Protector
Protection of 3 Phase devices against Over voltage, Under voltage,Single Phasing, Reverse Phasing & unbalance supply are one of the major issue in electrical systems. For safe running of 3-phase devices, special protections that keep a continuous watch on supply conditions are very essential. The major cause of maximum load burn-out is overloading which occurs due to unbalance supply, Single Phasing & Reverse Phasing conditions. VMR3P detects such Conditions & protect the load from burn out. 'PROTON's LVM 3P' offer above protections along with 3 digit display showing R-Y,Y-B,BR voltages in scanning mode with precise accuracy. LOW/HIGH voltage tripping to ensure trouble free running of 3-phase Loads. Additional auxiliary supply not required. Latest micro controller based technology. Wide range of supply variation. Unit also works with one phase is present. Additional auxiliary supply not required. Protection against Under voltage. Protection against Over voltage. Single Phasing & Reverse Phasing protection. Reverse Phasing Protection can be bypased through settings. Trip delays for all protections. Set Parameters are easy to handle with simple trimpot. LED indication for status of relay & Power.
...moreVoltage Monitoring Relay Three Phase
Protection of 3 Phase devices against Over voltage, Under voltage,Single Phasing, Reverse Phasing & unbalance supply are one of the major issue in electrical systems. For safe running of 3-phase devices, special protections that keep a continuous watch on supply conditions are very essential. The major cause of maximum load burn-out is overloading which occurs due to unbalance supply, Single Phasing & Reverse Phasing conditions. VMR3P detects such Conditions & protect the load from burn out. 'PROTON's VMR 3P' offer above protections along with 3 digit display showing R-Y,Y-B,B-R voltages in scanning mode with precise accuracy. LOW/HIGH voltage tripping to ensure trouble free running of 3-phase Loads. Indications: 1) SPP- RED LED 2) Over voltage- RED LED 3) Under voltage- RED LED 4) Relay ON - Green LED Relative Humidity 10 to 95% RH Mounting: Flush ON Delay: 1- 60 sec Cutout: 92 X 92 W Dimension : 96 X 96 Display : 7 Segment LED 3 digit Voltage trip setting:1) Lower limit is 340 for Under Voltage Upper limit is 460 volts for over Voltage (Resolution of 1V)2) Hysteresis bet cutoff & cutin is 10 V Micro controller based technology. Protection against under voltage, Over voltage. All set points settable by keys. Trip Delay is settable Reverse Phasing Protection can be bypassed through settings. Indications Voltage relay, fault relay ON. Message display for Under/Over Voltage./SPP Application Electrical Panels. Electrical Test benches Genset panels Package unit and central air conditioning plants. Compressor motors. Submersible pumps Cold storage's
...moreVoltage Monitoring Relay single Phase
Micro controller based technology. Protection against under voltage, Over voltage. All set points settable by keys. Trip Delay is settable Reverse Phasing Protection can be bypass through settings. Indications Voltage relay, fault relay ON. Message display for Under/Over Voltage. No separate auxiliary supply required.
Relative Humidity : 10 to 95% RH
...morevoltage monitoring relay
2,000 Per Piece
Number of Poles : 2 Pole, 3 Pole, 4 Pole, 5 Pole
Brand Name : Proton
Voltage Monitor Relay
Protection of 3 Phase devices against Over voltage, Under voltage,Single Phasing, Reverse Phasing & unbalance supply are one of the major issue in electrical systems. For safe running of 3-phase devices, special protections that keep a continuous watch on supply conditions are very essential. The major cause of maximum load burn-out is overloading which occurs due to unbalance supply, Single Phasing & Reverse Phasing conditions.
...moreVoltage Frequency Relay
Micro controller based technology. Protection against under voltage, Over voltage, Over Frequency and Under Frequency. All set points settable by keys. Trip Delay for voltage & Frequency is settable Reverse Phasing Protection can be bypass through settings. Indications Voltage relay, Freq relay ON. Message display for Under/Over Voltage & Under\Over Freq Faults. No separate auxiliary supply required.
...moreVoltage Frequency Monitoring Relay
Micro controller based technology. Voltage protection along with digital voltage readout. Wide range of supply variation. Unit will also works on any one phase is present. Protection against Under Voltage. Protection against Over Voltage. Single Phasing & Reverse Phasing protection. Control output All the set points settable by keys. Phase unbalance protection. Trip Delay for Under voltage & Unbalance is settable Reverse Phasing Protection can be able to bypass through settings. Indications for Low Voltage , High Voltage, SPP & Relay ON . Message Display for SPP, Reverse Phasing & Unbalance Faults. No separate auxiliary supply required. Hold feature:- Press INC key in Running condition to observe particular supply voltage 1) If the input supply is within the range of the fault limit limits then On Timer starts decrementing on display & after set on Time over Relay will de ON with RLY indication glowing 2)If OV , UV, OF, UF, SPP/ reverse phasing / Unbalance occurs in the supply then relay will be OFF after the trip delay of that particular fault & LED starts blinking 3) If any phase to Voltage increases above OV set point belay will trip after trip delay (100)ms ) over .If that particular phase to phase voltage reduces below COV set point Relay will be on after the set rest delay is over 4) If any Phase to Phase Voltage increases / reduces above / the UB set point compared to other two Phase to Phase voltages , Relay will trip after delay over If that particular phase to phase voltage reduces / increases below / above (UB set point -/+ 10-V ) relay will be ON after the set reset delay over If the frequency reduces below UF or increases above OF then the relay will trip . Hysteresis is 1H2 5)If any of the Phase fails , Relay will trip after trip delay (100ms) over If all phases are present , relay will be ON after the set reset delay is over 6) If Phase sequence is changed to R-B-Y/Y-R-B/B-R-Y; Relay will trip after the trip delay (100 ms) over . if phase sequence is corrected to R-Y-B, relay will after the delay over UB /SPP/REVP,UV,UF, OF.
...moreVoltage Current and Frequency Meter
VAF meter displays the Phase-Phase Voltages Phase - Neutral on the first row, Second row displays frequency & the Third row Displays the Ampere Value. VAF meter displays the Phase-Neutral Voltages, Frequency & the Ampere Values of the line, In the scrolling pattern.
...moreTemperature Controller
Telepac AC Controller
6,000 Per Piece
5 Piece (MOQ)
Supply Voltage:230 VAC ± 15 % for Single Phase 415 VAC ± 15% for Three Phase Separate power supplies for each AC & independent Outputs for Fan & Compressor Power Supply unit : for 3PN & 1 Ph Supply Dimensions : .1) Controller : 245 mm X 150 mm X 60 mm2)Power supply unit:-125mm X 68mm X168mm
Type : Ac Controllers
Color : Black
Voltage : 415 VAC
Frequency : 50hz
Body Material : Mild Steel
Power : 1-3kw
Power Source : Electric
Phase : Three Phase
Warranty : 1year
Country of Origin : India
...moreTap Position Indicator
We are one of the trustworthy names in offering range of Tap Position Indicator to our respected clients. Our offered products Tap Position Indicator is widely demanded for its portability, efficient performance and less power consumption.
...moreSubmersible Pump Starter Panel
The Starter Panel has is solid state Current Meters. It measures currents and provides protection against overload for both the motors. This is based on a Micro controller, programmed for the application. The Meter’s supplied preprogrammed for operation and can be directly installed Three digits 7 segment bright display for current. Parameter Setting: using front keys. User Programmable. Password protected set parameters. Inbuilt Single Phase 30 A Relay contact for load control. Message Display for faults. Display of Voltage and Under and Over Voltage protection Display of Current and Over Load and Dry Run protection Suitable for Auto Multi Port Valves as starter panel. Auto / Manual Operation Auto Multi Port valve power output ( in Auto Mode) Easy Panel mounting. 1 HP and 2 HP models.
...moreSpacemaker
Controls two air conditioners. Separate Phase Supply for each A/C. Bright Red 4 Digit LED Display Accurate Temperature sensing by precise temperature sensor. Time Sharing for Compressors to share load equally Voltage & Current protections for each compressor. Separate alarm relay contacts for AC Fail. Fire protection by Digital Input. Hour counters for Compressor ON Period to check its reliability. Display of all the A/C parameters & fault messages continuously in a scrolling manner. Display Hold Feature by using ENTER Key. Press it again to release the hold. Various set points are settable through the following different Menu categories: a] VEW b] SET c] RESET Password Protection for all the settings Sensor Fail Mode to keep ON & OFF cycle of A/C through sensor fail ON/OFF time settings Auto (with all protections)/manual (without protection) Modes . Controller Bypass feature by provision of Switch on Front Panel . LED Indications to observe the status .
Supply Voltage : 230 V AC, 50 Hz ï± 15% separate for each A/C.
Resolution : 1V for Voltage, 0.1 A for Current & 0.1ï°C for Temperature.
...moreSpace Maker
SALIENT FEATURES 1. Controls two air conditioners. 2. Separate Phase Supply for each A/C. 3. Bright Red 4 Digit LED Display. 4. Accurate Temperature sensing by precise temperature sensor. 5. Time Sharing for Compressors to share load equally. 6. Voltage & Current protections for each compressor. 7. Separate alarm relay contacts for AC Fail. 8. Fire protection by Digital Input 9. Hour counters for Compressor ON Period to check its reliability. 10. Display of all the A/C parameters & fault messages continuously in a scrolling manner. 11. Display Hold Feature by using ENTER Key. Press it again to release the hold. 12. Various set points are settable through the following different Menu categories:A] VIEWB] SETC] RESET 13. Password Protection for all the settings. 14. Sensor Fail Mode to keep ON&OFF cycle of one of the A/C through sensor fail ON/FF time settings 15. Auto (with all protections)/ manual (without protection) Modes. 16. Controller Bypass feature by provision of Switch on Front Panel. 17. LED Indications to observe the status.
...moreSingle Phase Protection Relay
Protection of induction motors against single phasing or reverse phasing or unbalance supply is one of the major problems in electrical systems. For safe running of 3-phase motors, special protections that keep a continuous watch on supply conditions are very essentials. The major cause of maxium motors burn-out is overloading which occurs due to unbalance supply or single phasing. Phase failure occurs in case of fuse blown-off, loose connections or loss of phase from supply itself.
...moreSingle Phase Preventer
Protection of induction motors against single phasing or reverse phasing or unbalance supply is one of the major problems in electrical systems. For safe running of 3-phase motors, special protections that keep a continuous watch on supply conditions are very essentials. The major cause of maxium motors burn-out is overloading which occurs due to unbalance supply or single phasing. Phase failure occurs in case of fuse blown-off, loose connections or loss of phase from supply itself.
...moreSingle Phase AC Power Monitor
The AC Power Monitor is a solid state Power Meter. Monitoring of single phase AC supply including all types of energies. The AC Power Monitor is based on a dual micro controller , with a high degree of programmability. The Meter has been programmed to operate as an intelligent front end measuring and storing device & serial port connectivity qualifies model AC Power Meter. The Meter’s supplied preprogrammed for operation and can be directly installed. The Meter can be read manually or through a RS-485 MODBUS RTU Protocol. Measured Parameters:- 1] RMS Voltage (Volt) Phase – Neutral measured. 2] RMS Current (Amps) Phase current. 3] Frequency. 4] Power Factor. 5] Active Power (KVA). No Auxiliary Power Supply required. Good reading stability, high reliability, and good quality of load. LCD Display (2X16 Char) with Back Light. Calibration: using front keys. Digital Input for D4 / Mains coad selection Voltage separation for RS 485 (MODBUS-RTU Protocol). Fully User Programmable. CT Ratio/Gain Settable. All Menus are Password Protected. Communication with PC ginen , Separate contact for communication TX & RX
...moreSensicool Controller
SALIENT FEATURES 1. Controls two air conditioners. 2. Separate Phase Supply for each A/C. 3. Bright Red 4 Digit LED Display 4. Accurate Temperature sensing by precise temperature sensor. 5. Time Sharing for Compressors to share load equally. 6. Voltage & Current protections for each compressor. 7. Separate alarm relay contacts forAC Fail. 8. Fire protection by Digital Input 9. Hour counters for Compressor ON Period to check its reliability. 10. Display of all the A/C parameters & fault messages continuously in a scrolling manner 11. Display Hold Feature by using ENTER Key. Press it again to release the hold. 12. Various set points are settable through the following different Menu categories: a] VIEW b] SET c] RESET 13. Password Protection for all the settings. 14. Sensor Fail Mode to keep ON & OFF cycle of one of the A/C through sensor fail ON/FF time settings. 15. Auto (with all protections)/Manual (without protection) Modes. 16. Controller Bypass feature by provision of Switch on Front Panel. 17. LED Indications to observe the status.
...morerpm indicator
RPM indicators are useful for indicating wide range of rotating machine speeds. These are non contact type Digital tachometers which work with external proximity or optical sensor to measure the revolution speed either in terms of RPM (revolutions per minute) or RPS (revolutions per second) or in desired units like meters per minute etc. These instruments are also known as Speed Indicators / Frequency Indicators / Digital Tachometers.
Resolution : 1 RPM
...moreRO Control cum Starter Panel
The RO Control cum Starter Panel is a Micro Controller based solid state compact unit. It measures Mains Voltage and Currents at Raw Water Pump (RWP) and High Pressure Pump (HPP). It provides Over and Under Voltage protection as well as Overload and Under Load (Dry Run) protection for both the pump motors. Voltage and Current protection settings are user settable with a password protection. Process interlocks like Low Pressure at HPP suction, High Pressure at HPP delivery and Product Tank Level High are pre-programmed for reliable operation of the plant. Controller also provides Flush Valve Solenoid and Dosing Pump power control. Low Pressure trip delay and Flush timings are settable. All the electrical trip delay timings are settable.
Voltage : 1 V
...moreReverse Osmosis Plant Controller
15,000 Per Piece
Voltage : 12 V DC, 24 V DC
Pump Starter with Automatic Tank Level Control
Water Level Controller is a state of the art instrument to control water pumps. It controls your pump as per levels in the overhead and underground water tanks and also guards your pump against power fluctuations(Over and Under Current)(for 3 Phase Pumps). It is a novel solution, ideal for all your water problems. Pump is Switched On when overhead tank is empty. It is Switched Off when either overhead tank is full or underground tank is empty. Water level controller cum indicator saves water and protects motor and reduces electricity bill. Our Automatic water level controller cum indicator serves 24 hours water supply without letting the overhead tank to become dry. Fully programmable Suitable for three phase pumps up to 7.5HP. No auxiliary power supply required for controller operation. . Complete protection from electrical unhealthy condition. All parameters are settable through front key. LED indications for alarm (fault). Scrolling display of parameters, one by one in scroll mode. Four bright 7 segment display on unit. Inverse Time trip curve for over load fault.
...moreBe first to Rate