Two Zone Fire Suppression System (FSS-021G)
As a quality-conscious firm, we make sure that the offered lot is sternly packed using the best quality packaging material. However, we source the packaging material from the genuine vendors. The organization is a trusted name based in Pune(India) and known for its fair pricing policy. Product Description : Fire Suppressants (Gas or Aerosol) are expensive and customers & installers are always concerned about reliability of the releasing system. Also they are concerned about accidental release. “Vighnaharta A3S” brings to you Fire Suppression Panels with unique features. They are NFPA & EN54-2 compliant and posses all the features required by international users. Panels are EMI/EMC tested and are protected against power line surges. Fault tolerant, intelligent, triple logic electronic hardware circuit coupled with intelligent software removes probability of accidental release. FSS models use conventional detectors. They can be interfaced with BMS, SCADA with the help of RS485 or Ethernet ports for remote monitoring. For GAS Suppressant Valve it has special monitoring circuit which can inform about Low Pressure of GAS. FSS-021G & FSS-042G Panel has Provide Optional Ethernet /GSM/ GPRS Connectivity OR CMS monitoring output also available . USPs : Extra Protection against accidental release GAS Valve Monitoring Circuit Note - Following Models Also Available : FSS-021G - Two Cross Zone, Single Gas Release FSS042G - Four Cross Zone, Dual Gas Release
...moreTwo Zone Fire Suppression System (FSS-021D)
We brings to you Fire Suppression Panels with unique features. They are NFPA & EN54-2 compliant and posses all the features required by international users. Panels are EMI/EMC tested and are protected against power line surges. Fault tolerant, intelligent, triple logic electronic hardware circuit coupled with intelligent software removes probability of accidental release. Product Description : Fire Suppressants (Gas or Aerosol) are expensive and customers & installers are always concerned about reliability of the releasing system. Also they are concerned about accidental release. “Vighnaharta A3S” brings to you Fire Suppression Panels with unique features. They are NFPA & EN54-2 compli-ant and posses all the features required by international users. Panels are EMI/EMC tested and are protected against power line surges. Fault tolerant, intelligent, triple logic elec-tronic hardware circuit coupled with intelligent software removes probability of accidental release. FSS models use conventional detectors. They can be interfaced with BMS, SCADA with the help of RS485 or Ether-net ports for remote monitoring. For Aerosol Cans it has special monitoring circuit which can inform about discon-nection or characteristic changes of the agent. FSS-021D & FSS-042D Panel has Provide Optional Ethernet /GSM/GPRS Connectivity OR CMS monitoring output also available.
...moreTrueSense Sensors
Description Available Sensors: Beam Detector Glass Break Sensor Vibration Sensor Motion Sensor Shutter Sensor Door Sensor LoRa Sensor 5D Sensor PIR sensor Intelligent Temperature Sensor  General Feature List  * Features are indicative and may not be available in each model. • Beam Detector – Beam Detector use invisible light to scan a defined area.• Glass Break Sensor – Glass Break Sensor is used for detecting glass vibration and breakage.• Vibration Sensor – Vibration Sensor recognizes movement or vibration.• Motion Sensor – Motion Sensor detects the movement of human body automatically in the detection area.• Shutter Sensor – Shutter Sensor senses automatically the opening of the shutter.• Door Sensor – Door Sensor able to monitor and detect theft.• 5D Sensor – 5D Sensor is designed specially for intrusion detection.• LoRa Sensor – Wireless Door Magnetic Sensor & Wireless Smoke detector based on LoRa technology.• Intelligent Temperature Sensor – Intelligent Temperature Sensor monitors ambient temperature of room, lobby, closed area.
...moreTrueSafe Smoke Detectors
Smoke detector is used to detect fire (which generates smoke). Many types of smoke detectors are in used based on different applications. Most widely used detectors use photoelectric technology. It uses detection of carbon particles present in smoke by using Infrared diodes. When smoke enters the chamber diode receives more light and the detector gives out alarm signal and also turn ON red led for local indication General Feature List    * Features are indicative and may not be available in each model. • Dual fire LED indication• LPCB, UL, Vds Approved• Photo-electric technology is used• Current output• Stylish look• Compatible with all fire panel• Low standby current
...moreResidential LPG Gas Leak Detector ( TS230HLB HLRB)
TS12HLB/HLRB are ideally suitable for applications where additional safety is required. The detector is positioned in such a way that gas leakage is detected as soon as possible. The output of the detector is Buzzer. Product Description : TS230HLB/HLRB are ideally suitable for applications where additional safety is required. The detector is positioned in such a way where gas leakage is detected as soon as possible. The output of the detector is Buzzer. Optional Relay and RS-485 output also available. Product Features & Specifications : Kitchen Platform Panel mountable. Automatic Calibration at the desired level of LEL (Usually 10% of LEL). In addition, it can detect heat. Can be interfaced with Gas Detection Panel through PFC relay output.
Brand Name : Vighnaharta
...moreResidential GAS DETECTION
 Description TrueSafe Residential Gas leak detector is designed for detection & early warning for LPG or CNG leakage from cylinders or through pipelines. This wall mounted unit is compact and designed for low cost domestic applications. The latest model, TrueSafe Cloud can talk to your Smartphone using your home wifi connection. In case of gas leakage at home you can get notified where ever you are. Note:- We do not recommend to use residential gas leak detectors in Hotels, Restaurants and parking due to challenging environmental conditions.  General Feature List * Features are indicative & may not be available in each model. • Kitchen Platform Panel mountable• Automatic Calibration at the desired level of LEL (Usually 10% of LEL).• In addition, it can detect heat• Can be interfaced with Gas Detection Panel through PFC relay output
...moreRefrigerant gas leak detectors
TS12(REF)R is ideal gas detector for detecting refrigerant gas leakages from Refrigeration systems in commercial and Industrial premises, Food Storage & Processing facilities, Supermarkets, Parking Garages, Wastewater Treatment Facilities, Hospitals and Universities. Variant models are available for different refrigerants like R410a, R408a etc. It has long life Semiconductor sensor. This model also provides Bargraph indication for level of concentration of gas. Four levels, 125, 250, 375 & 500 of PPM are provided. Alarm is indicated by sounding of beep at every level. After the concentration level crosses 500pm continuous alarm will sound and relay (PFC) output will change the status. It is available in Dustproof & Water Splash Proof – IP67 Enclosure. Models Available for following gases : HFC : R134a, R404a, R407c, R410a HCFC : R22, R401a, R406a, R408a, R409a. Gas Detector Models also available for other gases e.g. NH3, H2, H2S, Explosive Gases for different applications e.g. household, commercial and industrial.
Brand Name : Vighnaharta
...moreIntrusion panel
Intrusion Alarm Panel is a sophisticated home / office security system for protection against burglary or property damage. The system is designed to detect intrusion (unauthorized) entry in to building or area with the help of sensors. The system is kept at the user premises. System can read inputs from wired as well as wireless sensors. User can configure various parameters like zones, entry / exit delay, and contact numbers with help of key pad. LCD display on the front panel indicates the various activities. LED and buzzers are also used to report emergency. At the same time system reports to different users by sending SMS or voice call and central stations with the help of CID or SIA DC09 protocol.  General Feature List  * Features are indicative and may not be available in each model. • 9 wired (Microcontroller based) & 32 wireless sensors to detect an emergency condition• 16*2 Backlight LCD Display• Tactile 18 Keys Key Pad ( external keypad of 18 key supported)• Inbuilt GSM Auto Dialer• 10 Voice & 10 SMS Reporting Number Support• 20 Sec. pre-recorded voice message. Message Playback facility• Up to 100 Number of Event support• Provision for partial Arm. Auto Arm/Disarm zone facility and time/schedule based arming features• Arming & Disarming through keypad, wireless Keyfob, SMS and using Android App• Tampered proof enclosure and Audio Pop up for Arming conformation through Siren (2 sec)• Non-volatile memory to restore multiple programming• IP compatible support ( SIA DC 09 + Reverse command)- Add on card Â
...moreIndustrial Infra Red Type Gas Leak Detector
Buyers can stay rest assured for the delivery of the orders as we are backed by the most sophisticated transit system. we are a quality-conscious firm and for maintaining product quality, we consider several measures so as to ensure that only flawless lot reaches the buyers. Product Description : Industrial Infra Red Type Gas Leak Detector (TS21I IR) is suitable for all Hydrocarbon gases. Application area of this detector is Refineries and Petrochemical Plants, Oil and Gas , LPG station, Chemical and Pharma Industries, Fertilizer and Power plants, Gas Boiler, and Spray-Paints etc where gas leakage is possible. It reads the gas concentration in Air and transmits to a detection panel over digital bus as well as it shows LEL level on display. IR type of gas sensor is used in this detector. This sensor provides good reproducibility, good performance against changes in atmospheric temperature and humidity. It has long life-span and easy operation. Detector have provision to set Two alarm levels of warnings. PFC Relay output is provided and this output can be connected to the conventional Gas Detection Panel OR SCADA system. Product Features & Specifications : Gas Sampling Natural diffusion Detection Range—0-100% of LEL Preset Alarm Levels Low Alarm Level High Alarm Level Auto Calibrated Response Time T90 less than 30Sec. Infra Red sensor is used PFC Relay NO or NC PFC O/P and It will be Selectable Latching type or Pulse Type Sensor Life : Up to 10 years Analog O/P : Selectable 0-5 V & 0-10V output 4-20mA current output Operating Voltage Range is 12 to 30VDC
Brand Name : Vighnaharta
...moreIndustrial Grade Hydrogen Gas Leak Detector (TS21I-CAT-H2)
TS21I-CAT-H2 Industrial Grade Hydrogen Gas Leak Detector is suitable for all Hydrogen gases. Application area of this detector is Refineries, Chemical plant, Gas Cylinder Refilling and Battery Back Power Stations etc where gas leakage is possible. It reads the gas concentration in Air and transmits to a detection panel over digital bus as well as it is show LEL level on display. Catalytic type of gas sensor is used in this detector , This sensor is provide good reproducibility, good performance against changes in atmospheric temperature and humidity. It has long lifespan and easy operation. Detector have provision to set Two alarm levels of warnings.
Brand Name : Vighnaharta
...moreIndustrial Grade Hydrocarbon Gas Leak Detector (TS21I-CAT-HC)
TS21I-CAT-HC gas detector is suitable for all Hydrocarbon gases. Application area of this detector is Refineries, Chemical plant, LPG station, Gas Boiler, and Spray-Paints etc where gas leakage is possible. It reads the gas concentration in Air and transmits to a detection panel over digital bus as well as it is show LEL level on display. Catalytic type of gas sensor is used in this detector , This sensor is provide good reproducibility, good performance against changes in atmospheric temperature and humidity. It has long lifespan and easy operation. Detector have provision to set Two alarm levels of warnings. PFC Relay output is provided and this output can be connected to the conventional Gas Detection Panel OR SCADA system. For BMS connectivity detector have provide RS485 output. Catalytic sensor is used in this model. (Additionally 4-20mA and Selectable 0-5 V & 0-10V Analog output could be also available). Enclosure used is suitable for Zone 1 & Zone 2 hazardous areas. Note : Enclosure depicted above is indicative. Specs subject to change without notice.
Brand Name : Vighnaharta
...moreIndustrial Gas Detection
TrueSafe Industrial Gas Detector is designed for detection & early warning for gas leakage from cylinders or through pipelines. Large industries or large hotel kitchens use several gas cylinders or gas banks. There is possibility of gas leakage and the severity of fire / explosion hazard is very high. The TrueSafe ILR is used for safety purpose in hazardous areas where there are chances of gas leakage. This wall mounted unit is designed for permanent installation with replaceable sensor. TrueSafe Industrial Gas Detector is available for Hydrogen, Ammonia, Carbon Monooxide, Sulpher Dioxide, Hydrogen Sulphide, Chlorine, Oxygen, Acetylene, Nitrogen Dioxide, Nitric Oxide, Formaldehyde gases. General Feature List * Features are indicative and may not be available in each model. • Gas Sampling by Natural diffusion• Detection Range—0-100% of LEL• Preset Alarm Levels a) Low Alarm Level b) High Alarm Level• Auto Calibrated• Response Time(< 2Sec.)• Catalytic sensor is used• Flame Proof Enclosure is used• Sensor Life : Up to 5 years• ATEX Certified
...moreIndustrial Electrochemical Type Gas Leak Detectors TS21I ELE
TS21I ELE id Industrial Electrochmical type gas leak detector. Electrochemical type of gas sensor is used in this detector. This sensor provides good reproducibility, good performance against changes in atmospheric temperature and humidity. It has long life-span and easy operation. Detector have provision to set Two alarm levels of warnings. PFC Relay output is provided and this output can be connected to the conventional Gas Detection Panel OR SCADA system. For BMS connectivity detector have provide RS485 output. Electrochemical Sensor is used in this model which does not required calibration frequently. (Additionally 4-20mA and Selectable 0-5 V & 0-10V Analog output could be also available). Enclosure used is suitable for Zone 1 & Zone 2 hazardous areas. Application area of this detector is Refineries and Petrochemical Plants, Chemical and Pharma Industries, Fertilizer, food industries, mining projects etc. where gas leakage is possible.
Brand Name : Vighnaharta
...moreHydrogen Gas Leak Detector
Hydrogen gas leak detector TS12C-Ex gas detector is suitable for all Hydrogen gases. Application area of this detector is Refineries, Chemical plant, Gas Cylinder Refilling and Battery Bank Power Stations etc where gas leakage is possible. It reads the gas concentration in Air and transmits to a detection panel over digital bus . Semiconductor type of gas sensor is used in this detector .This sensor is provide good reproducibility, good performance against changes in atmospheric temperature and humidity. It has long life-span and easy operation.
...morehydrogen detector
Safety of commercial & industrial kitchens is of prime importance.TS12CHR Commercial Grade Gas Hydrogen Detectors can detect Hydrogen and warn before the gas density in air reaches unwanted levels. This model also provides Bar-graph indication for level of concentration of gas.
...moregsm autodialer
9,200 Per Piece
2 Piece (MOQ)
Frequency : 50-60 Hz
Power Consumption : 2W Max.
GSM Auto Dialler
Hailing from Pune(India), the company is known for providing only quality products at reasonable prices. The offered lot is in complete compliance with the industry standards thus, high in demand. Product Description : AD4010-GSM Auto Dialler is an GSM auto dialer is an electronic device that can automatically dial telephone numbers to communicate between any two points in the telephone, mobile phone networks. Once the call has been established the GSM auto dialer will announce verbal messages to the called party you can also receive both text message and call. The GSM auto dialer has trigger 4 trigger Input and If any one is triggers system generates separate text messages and voice message, if trigger 1 got opened or closed then its text and voice message will be sent to the stored 10 telephone number. You can also activate and de-activate the system Relay Output through Android App.
...moreGSM Auto Dialer
05 Pack(s) (MOQ)
GSM Auto Dialer is used for continuous monitoring and reporting alarm conditions to users. The unit has 4 digital potential free or 12 V DC active inputs. When any input changes its state, alert message is sent to the user by SMS or voice call. For every input, unique separate SMS is sent to reporting numbers. Maximum up to 10 different persons can be notified with the alert. The unit has 2 potential free outputs. The output can be connected to any third party monitoring systems such as SCADA, PLC and so on. It can also be connected to notification devices such as sounders or sirens. The output can be controlled through SMS by the user. General Feature List   * Features are indicative and may not be available in each model. • 4 Inputs (Programmable NO or NC)• 4 Voice Messages (One for Each Input)• 4 SMS Messages (One for Each Input)• 10 Tel No’s for Voice Message Reporting• 10 Separate Tel No’s for SMS Reporting Â
...moreCommercial Type Hydogen Gas Leak Detector
Safety of commercial & industrial kitchens is prime importance.TS12CHR Commercial Grade Hydrogen Gas Detectors can detect Hydrogen and warn before the gas density in air reaches unwanted levels. This model also provides Bar-graph indication for level of concentration of gas. Four levels, 2.5%, 5%, 7.5% & 10% of LEL are provided. â€Â¢ Dustproof & Water Splash proof – IP65 Enclosure â€Â¢ Replaceable Filter â€Â¢ Only Commercial Detector available with LEL Bargraph â€Â¢ Can be interfaced with Gas Detection Panel
Brand Name : Vighnaharta
...moreGas Detection System - GS1600
GS-1600 is a highly versatile and economical module having Analog Inputs with RS485 / Ethernet port for online communication. It is an ideal solution for SCADA applications in Process Industries. GS - 1600 can be used along with PLC's thus reducing project cost substantially. Analog input to Gas etection System can be mA / Thermocouple or Voltage different for each channel. The unit has seven segment LED display for displaying process value, thus providing local indication to the operator. The Alarm / Control status of each channel is indicated on front LEDs. Serial port RS485 - 2 wire with Modbus RTU protocol or Ethernet with MODBUS TCP is provided. This feature makes Gas Detection System compatible with all the standard SCADA software and PLC's used in Industry. Optional Internal relay output 1 or 2 for common alarm. External relay output 8 or 16 for Individual alarm / Alarm & Trip / Control. Ethernet communication facility with MODBUS TCP protocol. Product Features & Specifications: • Gas Sampling by Natural diffusion • Detection Alarm level : 10% LEL (2000 PPM) • Preset Alarm Levels • Auto Calibrated • Low Response Time • Semiconductor sensor is used • PFC Relay NO or NC PFC O/P • Fire Proof Enclosure is used.
Brand Name : Vighnaharta
...moregas detection system
Gas Detection System is a sophisticated home / office Gas security system for protection against property damage. The system is designed to detect gas leakage in to building or area with the help of multiple sensors. The system is kept at the user premises. System can read inputs from wired sensors. User can configure various parameters like zone names, date, and time help of key pad. LCD display on the front panel indicates the various activities. LED and buzzers are also used to report emergency. General Feature List  * Features are indicative and may not be available in each model. • Dual LED GAS Detection Indication• Touch Capacitive Key Pad• GAS Control Valve Output• Low Battery Indication• Battery Disconnect Indication   Â
...moreFour Zone Fire Suppression System (FSS-042D)
We brings to you Fire Suppression Panels with unique features. They are NFPA & EN54-2 compliant and posses all the features required by international users. Panels are EMI/EMC tested and are protected against power line surges. Fault tolerant, intelli-gent, triple logic electronic hardware circuit coupled with intelligent software removes probability of accidental release. Product Description : Fire Suppressants (Gas or Aerosol) are expensive and customers & installers are always concerned about reliability of the releasing system. Also they are concerned about accidental release. “Vighnaharta A3S” brings to you Fire Suppression Panels with unique features. They are NFPA & EN54-2 compliant and posses all the features required by international users. Panels are EMI/EMC tested and are protected against power line surges. Fault tolerant, intelli-gent, triple logic electronic hardware circuit coupled with intelligent software removes probability of accidental release. FSS models use conventional detectors. They can be interfaced with BMS, SCADA with the help of RS485 or Ethernet ports for remote monitoring. For Aerosol Cans it has special monitoring cir-cuit which can inform about disconnection or characteristic changes of the agent.
...moreFire Suppression System
Fire can have an enormous impact on any institution or company, so to protect from these kinds of incidences, this system can be helpful. This Fire Suppression System (FSS) is specially designed for fire indications, early warnings, and fire suppression facility. The FSS042D is a multi zone fire suppression panel for single and dual hazard agent releasing applications. The FSS provides reliable fire detection, signalling and protection for commercial, industrial and institutional buildings requiring agent-based releasing.  General Feature List   * Features are indicative and may not be available in each model. • Class B Initiating Device Circuits (IDC) – 2 nos – For Conventional Smoke Detectors• Class B Releasing Agent Circuits (RAC) – 2 nos (D: Aerosol Can Monitoring – 2Cans.)• Class B Notification Appliance Circuits (NAC) – 1nos—For Hooter/Sounder etc• Fire / Fault status in unambiguous colors LED indication• Programmable Inputs for Pressure Switch, Inhibit/Abort Switch & Instant Release Switch and one spare• Programmable Mode (Auto/Manual) Selection & Zone Isolation facility• RAC Monitoring• BMS Connectivity• Up to 1000 Events Memory log support
...moreFire Alarm System
There are two types of panels – Conventional & Addressable. Conventional panels are suitable for small applications like Office, Godown, Store or Small Projects & Addressable panels are suitable for Factories, Industries, Control Rooms, Airport etc. Smoke detectors in a zone (or area) of the building are all connected to the same pair of wires. If any of these detectors report alarm, a single indication is shown on the control panel, means that the exact location of the alarm is not shown but zone area will be indicated on panel.   General Features List   * Features are indicative and may not be available in each model. • Auto learn feature provide• Apollo XP95 & Discovery protocol Support• Single Loop Panel• Hindi & Tamil Language Support• SMS Reporting Up to 10 Mobile numbers• Operates on 180 – 265V , 50 Hz, AC Mains power supply• Standby (battery) backup 24V DC power supply with built in charger• 128×64 Dots graphics LCD Display• 12 push button Alfa numeric keys Keypad for easy programming• 4 level security password protection
...moreBe first to Rate